Clinical Chemistry
HOME HELP FEEDBACK SUBSCRIPTIONS ARCHIVE SEARCH TABLE OF CONTENTS
 QUICK SEARCH:   [advanced]


     


Clinical Chemistry 39: 522-529, 1993;
This Article
Right arrow Full Text (PDF)
Right arrow Alert me when this article is cited
Right arrow Alert me if a correction is posted
Services
Right arrow Email this article to a friend
Right arrow Similar articles in this journal
Right arrow Similar articles in PubMed
Right arrow Alert me to new issues of the journal
Right arrow Download to citation manager
Right arrow reprints & permissions
Citing Articles
Right arrow Citing Articles via HighWire
Right arrow Citing Articles via Google Scholar
Google Scholar
Right arrow Articles by Morrissey, N. E.
Right arrow Articles by Blend, M. J.
Right arrow Search for Related Content
PubMed
Right arrow PubMed Citation
Right arrow Articles by Morrissey, N. E.
Right arrow Articles by Blend, M. J.

Clinical Chemistry, Vol 39, 522-529, Copyright © 1993 by American Association for Clinical Chemistry

Modified method for determining carcinoembryonic antigen in the presence of human anti-murine antibodies [published erratum appears in Clin Chem 1993 Nov;39(11 Pt 1):2343]

NE Morrissey, SF Quadri, R Kinders, C Brigham, S Rose and MJ Blend
Humana Hospital-Michael Reese, Division of Nuclear Medicine, Chicago, IL 60616.

The increasing use of monoclonal antibodies (MAbs) for disease diagnosis and therapy has created a class of patients at risk for systematic error in clinical testing due to interference by human anti- murine antibodies (HAMA). HAMA interference is often difficult to detect and can cause either an increase or a decrease in apparent concentrations of antigen present. We undertook a clinical study to test a HAMA-resistant enzyme immunoassay (EIA) format for carcinoembryonic antigen (CEA) determination. Using the Food and Drug Administration-approved CEA-EIA Monoclonal One-Step Assay (Abbott) with the addition of an acid/heat extraction of patients' specimens, we found that the resulting CEA values accurately reflected the patients' status. We demonstrated that the acid/heat-extracted specimens yield linear dilution curves and show analytical recoveries of added CEA in the range of 76-123% in HAMA-positive specimens and 86-103% in HAMA- negative specimens. The correlation of CEA values in extracted vs unextracted specimens from 184 patients and control subjects was 0.9963. The CEA detection limit of the assay was 1.6 micrograms/L for the extracted samples.


The following articles in journals at HighWire Press have cited this article:


Home page
Clin. Chem.Home page
V. I. Luzzi, M. G. Scott, and A. M. Gronowski
Negative Thyrotropin Assay Interference Associated with an IgG{kappa} Paraprotein
Clin. Chem., April 1, 2003; 49(4): 709 - 710.
[Full Text] [PDF]


Home page
Annals of Clinical & Laboratory ScienceHome page
R. L. Bertholf, L. Johannsen, and G. Benrubi
False Elevation of Serum CA-125 Level Caused by Human Anti-Mouse Antibodies
Ann. Clin. Lab. Sci., October 1, 2002; 32(4): 414 - 418.
[Abstract] [Full Text] [PDF]


Home page
Clin. Chem.Home page
J.-C. Rymer, R. Sabatier, A. Daver, J. Bourleaud, M. Assicot, J. Bremond, J. Rapin, S. L. Salhi, B. Thirion, A. Vassault, et al.
A New Approach for Clinical Biological Assay Comparison and Standardization: Application of Principal Component Analysis to a Multicenter Study of Twenty-One Carcinoembryonic Antigen Immunoassay Kits
Clin. Chem., June 1, 1999; 45(6): 869 - 881.
[Abstract] [Full Text] [PDF]




HOME HELP FEEDBACK SUBSCRIPTIONS ARCHIVE SEARCH TABLE OF CONTENTS
Copyright © 1993 by the American Association for Clinical Chemistry.