Clinical Chemistry
HOME HELP FEEDBACK SUBSCRIPTIONS ARCHIVE SEARCH TABLE OF CONTENTS
 QUICK SEARCH:   [advanced]


     


Clinical Chemistry 39: 540-543, 1993;
This Article
Right arrow Full Text (PDF)
Right arrow Alert me when this article is cited
Right arrow Alert me if a correction is posted
Services
Right arrow Email this article to a friend
Right arrow Similar articles in this journal
Right arrow Similar articles in PubMed
Right arrow Alert me to new issues of the journal
Right arrow Download to citation manager
Right arrow reprints & permissions
Citing Articles
Right arrow Citing Articles via HighWire
Right arrow Citing Articles via Google Scholar
Google Scholar
Right arrow Articles by Wei, J. S.
Right arrow Articles by Wang, J. Y.
Right arrow Search for Related Content
PubMed
Right arrow PubMed Citation
Right arrow Articles by Wei, J. S.
Right arrow Articles by Wang, J. Y.

Clinical Chemistry, Vol 39, 540-543, Copyright © 1993 by American Association for Clinical Chemistry

High-molecular-mass alkaline phosphatase as a tumor marker for colorectal cancer: comparison of two test methods

JS Wei, NC Chung, LL Wei, WF Tzeng, TZ Liu and JY Wang
Laboratory of Clinical Enzymology, School of Medical Technology, Chang Gung Medical College, Taiwan, R.O.C.

We measured high-molecular-mass alkaline phosphatase (HiMwALP) in serum samples from patients with colorectal cancer by polyacrylamide gel electrophoresis (PAGE) and by column chromatography on diethylaminoethyl (DEAE)-cellulose. Determination of carcinoembryonic antigen (CEA) by an enzyme immunoassay, a frequently used cancer assessment method, was used for comparison. We studied patients with primary colorectal cancer (n = 72), using others with hemorrhoids (n = 38) for a comparison group. HiMwALP activities twice those of pooled normal sera were adopted as cutoff values. The diagnostic sensitivity of the PAGE method for 72 colorectal cancer patients was 63% vs 36% for the DEAE method and 50% for the CEA method. The diagnostic specificities of the PAGE, DEAE, and CEA methods were 89%, 79%, and 95%, respectively. Using both HiMwALP (PAGE method) and CEA for the detection of primary colorectal cancer increased the sensitivity to 72% but decreased specificity to 87%.


The following articles in journals at HighWire Press have cited this article:


Home page
Cancer Epidemiol. Biomarkers Prev.Home page
S. Hundt, U. Haug, and H. Brenner
Blood Markers for Early Detection of Colorectal Cancer: A Systematic Review
Cancer Epidemiol. Biomarkers Prev., October 1, 2007; 16(10): 1935 - 1953.
[Abstract] [Full Text] [PDF]




HOME HELP FEEDBACK SUBSCRIPTIONS ARCHIVE SEARCH TABLE OF CONTENTS
Copyright © 1993 by the American Association for Clinical Chemistry.