Clinical Chemistry Link to Randox Laboratories Web Site
HOME HELP FEEDBACK SUBSCRIPTIONS ARCHIVE SEARCH TABLE OF CONTENTS
 QUICK SEARCH:   [advanced]


     


Clinical Chemistry 39: 653-658, 1993;
This Article
Right arrow Full Text (PDF)
Right arrow Submit an electronic Letter to
the Editor about this paper
Right arrow Alert me when this article is cited
Right arrow Alert me when eLetters are posted
Right arrow Alert me if a correction is posted
Services
Right arrow Email this article to a friend
Right arrow Similar articles in this journal
Right arrow Similar articles in PubMed
Right arrow Alert me to new issues of the journal
Right arrow Download to citation manager
Right arrow reprints & permissions
Citing Articles
Right arrow Citing Articles via Google Scholar
Google Scholar
Right arrow Articles by Bakker, A. J.
Right arrow Articles by Lerk, R.
Right arrow Search for Related Content
PubMed
Right arrow PubMed Citation
Right arrow Articles by Bakker, A. J.
Right arrow Articles by Lerk, R.

Clinical Chemistry, Vol 39, 653-658, Copyright © 1993 by American Association for Clinical Chemistry

Rapid determination of serum myoglobin with a routine chemistry analyzer

AJ Bakker, DA Boymans, D Dijkstra, JP Gorgels and R Lerk
Department of Clinical Chemistry, Klinisch Chemisch Laboratorium, Leeuwarden, The Netherlands.

A turbidimetric immunoassay system (Turbitime system, Behringwerke AG) allows rapid determination of myoglobin in serum. We adapted the reagents for this myoglobin assay (Turbiquant myoglobin) for use with a Hitachi 717 analyzer. No high-dose hook effect was observed up to 15,000 micrograms/L. Interassay CVs were 4.6% (mean = 72.0 micrograms/L; n = 9) and 2.5% (mean = 365.6 micrograms/L; n = 11). The calibration curve was stable for at least 1 month. Hemolysis did not interfere, and turbidity from lipemia interfered only when absorbance exceeded 2.0 A. Results of this method (y) correlated well with those by the Turbitime method (y = 1.256x - 44.1 micrograms/L; n = 91; r = 0.991) and by a commercially available radioimmunoassay (Byk-Sangtec; y = 0.739x - 42.2 micrograms/L; n = 94; r = 0.991). The upper limit (95th percentile) of the reference interval for myoglobin was estimated at 57.9 micrograms/L. The positive predictive value for results of myoglobin at admission was 89% with this upper reference limit and 99% with 100 micrograms/L, whereas the negative predictive value was about 60% for both limits.





HOME HELP FEEDBACK SUBSCRIPTIONS ARCHIVE SEARCH TABLE OF CONTENTS
Copyright © 1993 by the American Association for Clinical Chemistry.