Clinical Chemistry AACC Online Job Center
HOME HELP FEEDBACK SUBSCRIPTIONS ARCHIVE SEARCH TABLE OF CONTENTS
 QUICK SEARCH:   [advanced]


     


Clinical Chemistry 39: 833-835, 1993;
This Article
Right arrow Full Text (PDF)
Right arrow Submit an electronic Letter to
the Editor about this paper
Right arrow Alert me when this article is cited
Right arrow Alert me when eLetters are posted
Right arrow Alert me if a correction is posted
Services
Right arrow Email this article to a friend
Right arrow Similar articles in this journal
Right arrow Similar articles in PubMed
Right arrow Alert me to new issues of the journal
Right arrow Download to citation manager
Right arrow reprints & permissions
Citing Articles
Right arrow Citing Articles via HighWire
Right arrow Citing Articles via Google Scholar
Google Scholar
Right arrow Articles by Kilpatrick, E. S.
Right arrow Articles by Dominiczak, M. H.
Right arrow Search for Related Content
PubMed
Right arrow PubMed Citation
Right arrow Articles by Kilpatrick, E. S.
Right arrow Articles by Dominiczak, M. H.

Clinical Chemistry, Vol 39, 833-835, Copyright © 1993 by American Association for Clinical Chemistry

Increased fetal hemoglobin in insulin-treated diabetes mellitus contributes to the imprecision of glycohemoglobin measurements

ES Kilpatrick, M Small, A Rumley and MH Dominiczak
Department of Pathological Biochemistry, Western Infirmary, Glasgow, Scotland, UK.

An increased prevalence of fetal hemoglobin (HbF) has been described in pediatric insulin-dependent patients. The popular electroendosmotic method for glycohemoglobin includes HbF. In an adult population comprising 50 insulin-treated and 57 non-insulin-treated diabetic patients and 57 control subjects, we measured HbF by HPLC and measured glycohemoglobin by both HPLC and an electroendosmotic method. Of the insulin-treated patients, 46% had concentrations of HbF > or = 0.5%, compared with 25% of non-insulin-treated patients and 23% of controls (P < 0.02). In the insulin-treated patients, the two glycohemoglobin methods correlated best when the HPLC measurements included HbF (r = 0.92 vs r = 0.84). Fructosamine concentrations correlated best with glycohemoglobin concentrations determined by methods that accounted for HbF. The true between-batch CV of the electroendosmotic assay increased (from 4.33% to 8.33%) when variable interpatient HbF concentrations were included. Thus, HbF must be considered when interpreting glycohemoglobin measured by an electroendosmotic method and when comparing it with other measures of glycemic control.


The following articles in journals at HighWire Press have cited this article:


Home page
BMJHome page
E. S Kilpatrick, A. G Rumley, M. H Dominiczak, and M. Small
Authors' reply
BMJ, March 18, 1995; 310(6981): 741 - 741.
[Full Text]


Home page
BMJHome page
S Bulusu
Variant haemoglobin may affect measurements
BMJ, March 18, 1995; 310(6981): 740b - 740.
[Full Text]


Home page
BMJHome page
E. S Kilpatrick, A. G Rumley, M. H Dominiczak, and M. Small
Authors' reply
BMJ, December 3, 1994; 309(6967): 1512 - 1512.
[Full Text]


Home page
BMJHome page
E S Kilpatrick, A G Rumley, M H Dominiczak, and M Small
Glycated haemoglobin values: problems in assessing blood glucose control in diabetes mellitus
BMJ, October 15, 1994; 309(6960): 983 - 986.
[Abstract] [Full Text]




HOME HELP FEEDBACK SUBSCRIPTIONS ARCHIVE SEARCH TABLE OF CONTENTS
Copyright © 1993 by the American Association for Clinical Chemistry.