Clinical Chemistry
HOME HELP FEEDBACK SUBSCRIPTIONS ARCHIVE SEARCH TABLE OF CONTENTS
 QUICK SEARCH:   [advanced]


     


Clinical Chemistry 39: 851-855, 1993;
This Article
Right arrow Full Text (PDF)
Right arrow Alert me when this article is cited
Right arrow Alert me if a correction is posted
Services
Right arrow Email this article to a friend
Right arrow Similar articles in this journal
Right arrow Similar articles in PubMed
Right arrow Alert me to new issues of the journal
Right arrow Download to citation manager
Right arrow reprints & permissions
Citing Articles
Right arrow Citing Articles via HighWire
Right arrow Citing Articles via Google Scholar
Google Scholar
Right arrow Articles by Tsanaclis, L. M.
Right arrow Articles by Wilson, J. F.
Right arrow Search for Related Content
PubMed
Right arrow PubMed Citation
Right arrow Articles by Tsanaclis, L. M.
Right arrow Articles by Wilson, J. F.

Clinical Chemistry, Vol 39, 851-855, Copyright © 1993 by American Association for Clinical Chemistry

Intra- and interlaboratory sources of imprecision in drug measurements by different techniques

LM Tsanaclis and JF Wilson
Cardiff Bioanalytical Services Ltd., Cardiff Business Technology Centre, UK.

We compared the intra- and interlaboratory precision of seven techniques used to measure eight antiepileptic drugs, digoxin, and theophylline by using data from the international Healthcontrol external quality-assessment scheme. Scheme participants were supplied blind with 6 or 12 sets of duplicate lyophilized serum samples. Each set contained different drug concentrations, and duplicates were analyzed separately, 1 to 6 months apart. The intra- and interlaboratory components of assay variance were isolated and compared by Bartlett's test for homogeneity of variance. Fluorescence polarization immunoassay (Abbott) showed the best overall intra- and interlaboratory performance for a range of analytes. The largest intralaboratory errors were produced by techniques using the Syva EMIT assays. Our analysis of the data shows that for most analyte/technique combinations, intralaboratory sources of variation were more important than interlaboratory sources. Gains in assay precision will therefore result from attention to internal laboratory procedures.


The following articles in journals at HighWire Press have cited this article:


Home page
Clin. Chem.Home page
J. F. Wilson and K. Barnett
Variation with Time in Components of Variance for Measurements of Therapeutic Drugs
Clin. Chem., December 1, 2005; 51(12): 2385 - 2387.
[Full Text] [PDF]


Home page
Clin. Chem.Home page
J. F. Wilson, I. D. Watson, J. Williams, P. A. Toseland, A. H. Thomson, G. Sweeney, B. L. Smith, L. N. Sandle, J. D. Ramsey, and N. E. Capps
Primary Standardization of Assays for Anticonvulsant Drugs: Comparison of Accuracy and Precision
Clin. Chem., November 1, 2002; 48(11): 1963 - 1969.
[Abstract] [Full Text] [PDF]


Home page
Clin. Chem.Home page
A. Scholer, J. Boecker, U. Engelmayer, K. Feldmann, D. Hannak, R. Kattermann, M. Oellerich, H. Raith, H. Schlebusch, H. Wieland, et al.
Comparability of a new turbidimetric digoxin test with other immunochemical tests and with HPLC—a multicenter evaluation
Clin. Chem., January 1, 1997; 43(1): 92 - 99.
[Abstract] [Full Text] [PDF]




HOME HELP FEEDBACK SUBSCRIPTIONS ARCHIVE SEARCH TABLE OF CONTENTS
Copyright © 1993 by the American Association for Clinical Chemistry.