Clinical Chemistry AACC Online Job Center
HOME HELP FEEDBACK SUBSCRIPTIONS ARCHIVE SEARCH TABLE OF CONTENTS
 QUICK SEARCH:   [advanced]


     


Clinical Chemistry 39: 1033-1036, 1993;
This Article
Right arrow Full Text (PDF)
Right arrow Submit an electronic Letter to
the Editor about this paper
Right arrow Alert me when this article is cited
Right arrow Alert me when eLetters are posted
Right arrow Alert me if a correction is posted
Services
Right arrow Email this article to a friend
Right arrow Similar articles in this journal
Right arrow Similar articles in PubMed
Right arrow Alert me to new issues of the journal
Right arrow Download to citation manager
Right arrow reprints & permissions
Citing Articles
Right arrow Citing Articles via Google Scholar
Google Scholar
Right arrow Articles by Gascon, N.
Right arrow Articles by Gonzalez-Sastre, F.
Right arrow Search for Related Content
PubMed
Right arrow PubMed Citation
Right arrow Articles by Gascon, N.
Right arrow Articles by Gonzalez-Sastre, F.

Clinical Chemistry, Vol 39, 1033-1036, Copyright © 1993 by American Association for Clinical Chemistry

Dipyrone interference on several common biochemical tests

N Gascon, C Otal, C Martinez-Bru, J Merce, M Cortes, R Arcelus, JM Queralto, JM Sanchez and F Gonzalez-Sastre
Servei de Bioquimica i, Hospital de la Santa Creu i Sant Pau, Barcelona, Spain.

We studied the effect in vitro and in vivo of dipyrone on the determination of several biochemical tests in two analyzers, a Hitachi 747 and a Kodak Ektachem 700. From studies in vitro, we found significant interference by dipyrone (P < 0.05) in the determination of creatine kinase (CK), lactate dehydrogenase (LD), uric acid, triglycerides, cholesterol, aspartate aminotransferase, alanine aminotransferase, and urea nitrogen with both instruments, and in the determination of creatinine in the Ektachem analyzer. We also studied the effect of intravenously administered dipyrone in 14 patients. Dipyrone interfered significantly (P < 0.05) in the determination of CK, LD, uric acid, triglycerides, and cholesterol with both instruments, and creatinine only with the Ektachem analyzer. Using high- performance liquid chromatography (HPLC), we measured concentrations of dipyrone in the serum of patients who had received the drug and observed a negative correlation between the concentrations of dipyrone in the blood and the percentage of each analyte concentration.





HOME HELP FEEDBACK SUBSCRIPTIONS ARCHIVE SEARCH TABLE OF CONTENTS
Copyright © 1993 by the American Association for Clinical Chemistry.