Clinical Chemistry 39: 993-1000, 1993;
This Article
Right arrow Full Text (PDF)
Right arrow Submit an electronic Letter to
the Editor about this paper
Right arrow Alert me when this article is cited
Right arrow Alert me when eLetters are posted
Right arrow Alert me if a correction is posted
Services
Right arrow Email this article to a friend
Right arrow Similar articles in this journal
Right arrow Similar articles in PubMed
Right arrow Alert me to new issues of the journal
Right arrow Download to citation manager
Right arrow reprints & permissions
Citing Articles
Right arrow Citing Articles via HighWire
Right arrow Citing Articles via Google Scholar
Google Scholar
Right arrow Articles by Stockl, D.
Right arrow Articles by Reinauer, H.
Right arrow Search for Related Content
PubMed
Right arrow PubMed Citation
Right arrow Articles by Stockl, D.
Right arrow Articles by Reinauer, H.

Clinical Chemistry, Vol 39, 993-1000, Copyright © 1993 by American Association for Clinical Chemistry

Candidate reference methods for determining target values for cholesterol, creatinine, uric acid, and glucose in external quality assessment and internal accuracy control. I. Method setup

D Stockl and H Reinauer
Institut fur Standardisierung und Dokumentation im medizinischen Laboratorium e.V. INSTAND e.V., Dusseldorf, Germany.

In Germany, the target values for External Quality Assessment (EQA) and internal accuracy control are determined by Reference Methods for several analytes, including cholesterol, creatinine, uric acid, and glucose. We present candidate Reference Methods for these compounds, based on isotope dilution-gas chromatography--mass spectrometry methods that have been developed at INSTAND, one of the two official Germany EQA reference institutions. Each Reference Method target value is calculated from six independent measurements performed on three different days. The mean method CVs ranged from 0.66% for glucose to 0.96% for creatinine. The inaccuracy (bias) of the methods is < 0.7%, as compared with the Standard Reference Material 909 of the National Institute of Standards and Technology. The maximum total error of a Reference Method value, including the 95% confidence interval and systematic errors, is < 2.3%. The presented candidate Reference Methods have been successfully used to set target values in the German EQA scheme and the internal accuracy control of routine laboratories.


The following articles in journals at HighWire Press have cited this article:


Home page
Clin. Chem.Home page
G. L. Myers, W. G. Miller, J. Coresh, J. Fleming, N. Greenberg, T. Greene, T. Hostetter, A. S. Levey, M. Panteghini, M. Welch, et al.
Recommendations for Improving Serum Creatinine Measurement: A Report from the Laboratory Working Group of the National Kidney Disease Education Program
Clin. Chem., January 1, 2006; 52(1): 5 - 18.
[Abstract] [Full Text] [PDF]


Home page
Clin. Chem.Home page
A. Carobene, C. Ferrero, F. Ceriotti, A. Modenese, M. Besozzi, E. De Giorgi, M. Franzin, C. Franzini, M. G. Kienle, and F. Magni
Creatinine measurement proficiency testing: assignment of matrix-adjusted ID GC-MS target values
Clin. Chem., August 1, 1997; 43(8): 1342 - 1347.
[Abstract] [Full Text] [PDF]


Home page
Clin. Chem.Home page
U. Hannestad and A. Lundblad
Accurate and precise isotope dilution mass spectrometry method for determining glucose in whole blood
Clin. Chem., May 1, 1997; 43(5): 794 - 800.
[Abstract] [Full Text] [PDF]




HOME HELP FEEDBACK SUBSCRIPTIONS ARCHIVE SEARCH TABLE OF CONTENTS
Copyright © 1993 by the American Association for Clinical Chemistry.