Clinical Chemistry AACC Online Job Center
HOME HELP FEEDBACK SUBSCRIPTIONS ARCHIVE SEARCH TABLE OF CONTENTS
 QUICK SEARCH:   [advanced]


     


Clinical Chemistry 39: 1514-1518, 1993;
This Article
Right arrow Full Text (PDF)
Right arrow Submit an electronic Letter to
the Editor about this paper
Right arrow Alert me when this article is cited
Right arrow Alert me when eLetters are posted
Right arrow Alert me if a correction is posted
Services
Right arrow Email this article to a friend
Right arrow Similar articles in this journal
Right arrow Similar articles in PubMed
Right arrow Alert me to new issues of the journal
Right arrow Download to citation manager
Right arrow reprints & permissions
Citing Articles
Right arrow Citing Articles via HighWire
Right arrow Citing Articles via Google Scholar
Google Scholar
Right arrow Articles by Klee, G. G.
Right arrow Search for Related Content
PubMed
Right arrow PubMed Citation
Right arrow Articles by Klee, G. G.

Clinical Chemistry, Vol 39, 1514-1518, Copyright © 1993 by American Association for Clinical Chemistry

Tolerance limits for short-term analytical bias and analytical imprecision derived from clinical assay specificity

GG Klee
Department of Laboratory Medicine and Pathology, Mayo Clinic, Rochester, MN 55905.

I propose a method for defining tolerance limits for assay bias and assay imprecision, based on the effects of these tolerance limits on the clinical specificity of the assay. An analytical "error budget" is defined as the squared sums of the imprecision and bias errors. The maximum limit for this error budget is set at a value corresponding to a 50% increase in the false-positive rate for classifying healthy subjects. For gaussian distributions with +/- 2 SD used as decision limits, this error budget equates to 0.45 SD of combined within-person and between-person biological variation (SDBiol). To provide reasonable power for bias detection in an assay, I recommend that the SD of the assay be kept at less than half the bias limit. Then, for the gaussian distribution, the maximum bias limit should be < 0.36 SDBiol and the SD of the assay should be < 0.18 SDBiol. Procedures are provided for using the same principles to define tolerance limits for decision limits other than +/- 2 SD and for nongaussian distributions.


The following articles in journals at HighWire Press have cited this article:


Home page
Clin. Chem.Home page
R. Gambino
Glucose: A Simple Molecule That Is Not Simple to Quantify
Clin. Chem., December 1, 2007; 53(12): 2040 - 2041.
[Full Text] [PDF]


Home page
Clin. Chem.Home page
C. G. Fraser and P. Hyltoft Petersen
Analytical Performance Characteristics Should Be Judged against Objective Quality Specifications
Clin. Chem., March 1, 1999; 45(3): 321 - 323.
[Full Text] [PDF]


Home page
Clin. Chem.Home page
D. L. Witte, S. A. VanNess, D. S. Angstadt, and B. J. Pennell
Errors, mistakes, blunders, outliers, or unacceptable results: how many?
Clin. Chem., August 1, 1997; 43(8): 1352 - 1356.
[Abstract] [Full Text] [PDF]




HOME HELP FEEDBACK SUBSCRIPTIONS ARCHIVE SEARCH TABLE OF CONTENTS
Copyright © 1993 by the American Association for Clinical Chemistry.