Clinical Chemistry AACC Online Job Center
HOME HELP FEEDBACK SUBSCRIPTIONS ARCHIVE SEARCH TABLE OF CONTENTS
 QUICK SEARCH:   [advanced]


     


Clinical Chemistry 39: 1693-1700, 1993;
This Article
Right arrow Full Text (PDF)
Right arrow Submit an electronic Letter to
the Editor about this paper
Right arrow Alert me when this article is cited
Right arrow Alert me when eLetters are posted
Right arrow Alert me if a correction is posted
Right arrow Citation Map
Services
Right arrow Email this article to a friend
Right arrow Similar articles in this journal
Right arrow Similar articles in PubMed
Right arrow Alert me to new issues of the journal
Right arrow Download to citation manager
Right arrow reprints & permissions
Citing Articles
Right arrow Citing Articles via HighWire
Right arrow Citing Articles via Google Scholar
Google Scholar
Right arrow Articles by Mahoney, J. J.
Right arrow Articles by Van Kessel, A. L.
Right arrow Search for Related Content
PubMed
Right arrow PubMed Citation
Right arrow Articles by Mahoney, J. J.
Right arrow Articles by Van Kessel, A. L.

Clinical Chemistry, Vol 39, 1693-1700, Copyright © 1993 by American Association for Clinical Chemistry

Measurement of carboxyhemoglobin and total hemoglobin by five specialized spectrophotometers (CO-oximeters) in comparison with reference methods

JJ Mahoney, HJ Vreman, DK Stevenson and AL Van Kessel
Department of Pulmonary Physiology, Stanford University Hospital, CA 94305.

We measured total hemoglobin (CtHb) and carboxyhemoglobin (COHb) in 100 patients' blood samples by using five specialized spectrophotometers (CO-oximeters)--IL 482 CO-Oximeter, Corning 2500 CO-oximeter, Radiometer OSM 3 Hemoximeter, Corning 270 CO-oximeter, and the AVL 912 CO-Oxylite--and compared the results with those obtained with the manual cyanmethemoglobin method and a gas-chromatographic (GC) method, respectively. For the CtHb measurements, the differences between the cyanmethemoglobin method and the CO-oximeters were not clinically important for any model. For the blood COHb measurements, the direction of the bias relative to GC was dependent on COHb concentration. In general, the CO-oximeters underestimated COHb concentration for COHb > 2.5% of total hemoglobin but overestimated COHb concentration for COHb < or = 2.5%. We conclude that all five CO-oximeters compared favorably with the reference methods for CtHb and for high concentrations of COHb. However, the inaccuracy of CO-oximeters for low-concentration (< or = 2.5%) COHb measurements may make these instruments unsuitable for some applications.


The following articles in journals at HighWire Press have cited this article:


Home page
Clin. Chem.Home page
R. F. Labbe, H. J. Vreman, and D. K. Stevenson
Zinc Protoporphyrin: A Metabolite with a Mission
Clin. Chem., December 1, 1999; 45(12): 2060 - 2072.
[Abstract] [Full Text] [PDF]


Home page
Arch. Dis. Child. Fetal Neonatal Ed.Home page
M. Kaplan, H. J Vreman, C. Hammerman, and D. K Stevenson
Neonatal bilirubin production, reflected by carboxyhaemoglobin concentrations, in Down's syndrome
Arch. Dis. Child. Fetal Neonatal Ed., July 1, 1999; 81(1): 56F - 60.
[Abstract] [Full Text]


Home page
Clin. Chem.Home page
B. H. A. Maas, A. Buursma, R. A. J. Ernst, A. H. J. Maas, and W. G. Zijlstra
Lyophilized bovine hemoglobin as a possible reference material for the determination of hemoglobin derivatives in human blood
Clin. Chem., November 1, 1998; 44(11): 2331 - 2339.
[Abstract] [Full Text] [PDF]


Home page
Arch Pediatr Adolesc MedHome page
H. C. Lu, R. D. Shih, S. Marcus, B. Ruck, and T. Jennis
Pseudomethemoglobinemia: A Case Report and Review of Sulfhemoglobinemia
Arch Pediatr Adolesc Med, August 1, 1998; 152(8): 803 - 805.
[Abstract] [Full Text] [PDF]


Home page
Clin. Chem.Home page
N. Yukawa, T. Suzuoka, T. Saito, A. R. W. Forrest, M. Osawa, S. Takeichi, J. A. Brunelle, and R. F. Moran
Data Processing in CO-Oximeters That Use Overdetermined Systems • A manufacturer replies:
Clin. Chem., January 1, 1997; 43(1): 189 - 191.
[Full Text] [PDF]




HOME HELP FEEDBACK SUBSCRIPTIONS ARCHIVE SEARCH TABLE OF CONTENTS
Copyright © 1993 by the American Association for Clinical Chemistry.