Clinical Chemistry AACC Online Job Center
HOME HELP FEEDBACK SUBSCRIPTIONS ARCHIVE SEARCH TABLE OF CONTENTS
 QUICK SEARCH:   [advanced]


     


Clinical Chemistry 39: 1725-1728, 1993;
This Article
Right arrow Full Text (PDF)
Right arrow Submit an electronic Letter to
the Editor about this paper
Right arrow Alert me when this article is cited
Right arrow Alert me when eLetters are posted
Right arrow Alert me if a correction is posted
Services
Right arrow Email this article to a friend
Right arrow Similar articles in this journal
Right arrow Similar articles in PubMed
Right arrow Alert me to new issues of the journal
Right arrow Download to citation manager
Right arrow reprints & permissions
Citing Articles
Right arrow Citing Articles via Google Scholar
Google Scholar
Right arrow Articles by Collins, D. R.
Right arrow Articles by Raftery, E. B.
Right arrow Search for Related Content
PubMed
Right arrow PubMed Citation
Right arrow Articles by Collins, D. R.
Right arrow Articles by Raftery, E. B.

Clinical Chemistry, Vol 39, 1725-1728, Copyright © 1993 by American Association for Clinical Chemistry

Early diagnosis of acute myocardial infarction with use of a rapid immunochemical assay of creatine kinase MB isoenzyme

DR Collins, DJ Wright, MG Rinsler, P Thomas, S Bhattacharya and EB Raftery
Department of Clinical Chemistry, Northwick Park Hospital, Harrow, Middlesex, UK.

In 195 patients presenting with chest pain and referred acutely for cardiological assessment, blood was taken immediately for assay of creatine kinase (CK; EC 2.7.3.2) MB isoenzyme by an immunochemical method and results [mass units of enzyme per liter of plasma (microgram/L)] were obtained within 30 min of sampling. Diagnosis of acute myocardial infarction in the patients was made independently, based on electrocardiograms and conventional cardiac enzyme profiles. The administration of any thrombolytic therapy in response to the CK-MB concentration result was also noted, allowing assessment of the assay's potential influence on patient management in addition to the diagnostic efficiency evaluation. The study demonstrated that, when blood samples were collected on admission to hospital and the decision level suggested by the manufacturers was utilized, the assay had an immediate sensitivity of 52% and a specificity of 97%. Of the 81 patients who were shown by conventional means to have had acute myocardial infarction, 8 (10%) had equivocal electrocardiograms but positive CK-MB concentration results. In four of these patients (5%), thrombolytic therapy was given on the basis of the clinical features and a positive CK-MB concentration result alone.





HOME HELP FEEDBACK SUBSCRIPTIONS ARCHIVE SEARCH TABLE OF CONTENTS
Copyright © 1993 by the American Association for Clinical Chemistry.