Clinical Chemistry Link to Randox Laboratories Web Site
HOME HELP FEEDBACK SUBSCRIPTIONS ARCHIVE SEARCH TABLE OF CONTENTS
 QUICK SEARCH:   [advanced]


     


Clinical Chemistry 39: 1907-1910, 1993;
This Article
Right arrow Full Text (PDF)
Right arrow Submit an electronic Letter to
the Editor about this paper
Right arrow Alert me when this article is cited
Right arrow Alert me when eLetters are posted
Right arrow Alert me if a correction is posted
Services
Right arrow Email this article to a friend
Right arrow Similar articles in this journal
Right arrow Similar articles in PubMed
Right arrow Alert me to new issues of the journal
Right arrow Download to citation manager
Right arrow reprints & permissions
Citing Articles
Right arrow Citing Articles via HighWire
Right arrow Citing Articles via Google Scholar
Google Scholar
Right arrow Articles by Wang, S. T.
Right arrow Articles by Demshar, H. P.
Right arrow Search for Related Content
PubMed
Right arrow PubMed Citation
Right arrow Articles by Wang, S. T.
Right arrow Articles by Demshar, H. P.

Clinical Chemistry, Vol 39, 1907-1910, Copyright © 1993 by American Association for Clinical Chemistry

Rapid Zeeman atomic absorption determination of copper in serum and urine

ST Wang and HP Demshar
Chemistry Section, Ontario Ministry of Health, Etobicoke, Canada.

In this simple, quick procedure for determining copper in human serum and urine, the serum and urine specimens were analyzed directly after dilution with a solution of HNO3 and Triton X-100, 1 mL/L each. We calibrated with aqueous standards for quantitation in Zeeman background atomic absorption spectrometry. By modifying the drying and pyrolysis stages of the graphite furnace atomic absorption spectrometer, we reduced the analytical time to 30 s per determination. The within-run imprecision (CV) is 2.6% and 3.4% and the between-run imprecision is 0.9% and 2.5% for serum and urine copper at concentrations of 30.4 and 2.70 mumol/L, respectively. The accuracy of this fast method was verified by analyzing the National Institute of Standards and Technology Standard Reference Materials SRM 1598 bovine serum and SRM 2670 urine (agreement with certified values within 0.1 mumol/L for serum and within 0.02 mumol/L for urine), by analytical recovery studies (98% recovered in serum, 100% recovered in urine), and by comparison with our normal routine method. We also used the Quebec Interlaboratory Comparison Program to validate the analytical performance. From the precision and accuracy studies, we conclude that this fast-furnace program is a rapid, simple, and reliable method for determining copper in serum and urine.


The following articles in journals at HighWire Press have cited this article:


Home page
Anesth. Analg.Home page
D. Holst, M. Mollmann, B. Schymroszcyk, C. Ebel, and M. Wendt
No Risk of Metal Toxicity in Combined Spinal-Epidural Anesthesia
Anesth. Analg., February 1, 1999; 88(2): 393 - 393.
[Abstract] [Full Text] [PDF]




HOME HELP FEEDBACK SUBSCRIPTIONS ARCHIVE SEARCH TABLE OF CONTENTS
Copyright © 1993 by the American Association for Clinical Chemistry.