Clinical Chemistry
HOME HELP FEEDBACK SUBSCRIPTIONS ARCHIVE SEARCH TABLE OF CONTENTS
 QUICK SEARCH:   [advanced]


     


Clinical Chemistry 40: 1956-1961, 1994;
This Article
Right arrow Full Text (PDF)
Right arrow Alert me when this article is cited
Right arrow Alert me if a correction is posted
Services
Right arrow Email this article to a friend
Right arrow Similar articles in this journal
Right arrow Similar articles in PubMed
Right arrow Alert me to new issues of the journal
Right arrow Download to citation manager
Right arrow reprints & permissions
Citing Articles
Right arrow Citing Articles via Google Scholar
Google Scholar
Right arrow Articles by Zucchelli, G. C.
Right arrow Articles by Masini, S.
Right arrow Search for Related Content
PubMed
Right arrow PubMed Citation
Right arrow Articles by Zucchelli, G. C.
Right arrow Articles by Masini, S.

Clinical Chemistry, Vol 40, 1956-1961, Copyright © 1994 by American Association for Clinical Chemistry

Systematic differences between commercial immunoassays for free thyroxine and free triiodothyronine in an external quality assessment program

GC Zucchelli, A Pilo, MR Chiesa and S Masini
CNR-Institute of Clinical Physiology, Pisa, Italy.

Data collected in a national external quality assessment program for free thyroxine (fT4) and free triiodothyronine (fT3) were analyzed to evaluate the performance of 10 method/kits with 26 control samples distributed to approximately 170 laboratories. The control materials were normal serum pools, pooled sera supplemented with thyroid hormones, a pregnancy serum pool, serum pooled from patients with familial dysalbuminemic hyperthyroxinemia (FDH), and a normal serum pool progressively diluted. The between-laboratory variability (CV) was approximately constant in normal and supplemented pools for fT4 (15.3%) and fT3 (24.0%) but markedly increased in diluted, pregnancy, and FDH pools (21.9-35.2% for fT4 and 28.6-66.5% for fT3) because of increases in systematic between-kit differences in control samples with altered binding-protein capacity. Moreover, free hormone concentrations measured in progressively diluted sera averaged lower than in undiluted samples. This decrease of concentration was less for back-titration or labeled-antibody techniques and greater for labeled-analog methods; only the method involving adsorption to cross-linked dextran (Sephadex) was unaffected by dilution. Evaluation of the reproducibility of the method/kits showed between-assay, between-laboratory precision ranging from 7.8% to 17.0% for fT4 and from 9.8% to 20.3% for fT3.





HOME HELP FEEDBACK SUBSCRIPTIONS ARCHIVE SEARCH TABLE OF CONTENTS
Copyright © 1994 by the American Association for Clinical Chemistry.