Clinical Chemistry
HOME HELP FEEDBACK SUBSCRIPTIONS ARCHIVE SEARCH TABLE OF CONTENTS
 QUICK SEARCH:   [advanced]


     


Clinical Chemistry 40: 216-220, 1994;
This Article
Right arrow Full Text (PDF)
Right arrow Alert me when this article is cited
Right arrow Alert me if a correction is posted
Services
Right arrow Email this article to a friend
Right arrow Similar articles in this journal
Right arrow Similar articles in PubMed
Right arrow Alert me to new issues of the journal
Right arrow Download to citation manager
Right arrow reprints & permissions
Citing Articles
Right arrow Citing Articles via HighWire
Right arrow Citing Articles via Google Scholar
Google Scholar
Right arrow Articles by Wu, A. H.
Right arrow Articles by Hill, D.
Right arrow Search for Related Content
PubMed
Right arrow PubMed Citation
Right arrow Articles by Wu, A. H.
Right arrow Articles by Hill, D.

Clinical Chemistry, Vol 40, 216-220, Copyright © 1994 by American Association for Clinical Chemistry

Characterization of drug interferences caused by coelution of substances in gas chromatography/mass spectrometry confirmation of targeted drugs in full-scan and selected-ion monitoring modes

AH Wu, D Ostheimer, M Cremese, E Forte and D Hill
Forensic Toxicology Laboratory, Hartford Hospital, CT 06102.

Interference by substances coeluting with targeted drugs is a general problem for gas chromatographic/mass spectrometric analysis of urine. To characterize these interferences, we examined human urine samples containing benzoylecgonine and fluconazole, and other drug combinations including deuterated internal standards that coelute (ISd,c) with target drugs, by selected-ion monitoring (SIM) and full-scan mass spectrometry. We show that, by SIM analysis, detecting the presence of an interferent is dependent on the specific IS used for the assay. When an ISd,c is used, the presence of another coeluting substance (interferent) suggests that the intensity of IS ions is substantially diminished, because the interferent affects both the ISd,c and target drug. When a noncoeluting IS (ISnc) is used, the interferent cannot be discerned unless it coincidently contains one or more of the ions monitored for either the target drug or ISnc. Under full-scan analysis, a coeluting interferent is directly discernable by examining the total ion gas chromatogram.


The following articles in journals at HighWire Press have cited this article:


Home page
Annals of Clinical & Laboratory ScienceHome page
G. M. Reisfield, E. Salazar, and R. L. Bertholf
Rational Use and Interpretation of Urine Drug Testing in Chronic Opioid Therapy
Ann. Clin. Lab. Sci., January 1, 2007; 37(4): 301 - 314.
[Abstract] [Full Text] [PDF]


Home page
Clin. Chem.Home page
R. L. Fitzgerald, D. A. Herold, and A. L. Yergey
Trade-offs in Mass Spectrometry
Clin. Chem., June 1, 1997; 43(6): 915 - 915.
[Full Text] [PDF]