|
|
||||||||
Clinical Chemistry, Vol 40, 472-477, Copyright © 1994 by American Association for Clinical Chemistry
C Ricos, CV Jimenez, A Hernandez, M Simon, C Perich, V Alvarez, J Minchinela and M Macia
General Hospital Vall d'Hebron, Barcelona, Spain.
To determine the influence of biological variation on the reliability of data from different types of urine specimens, we measured nine analytes in first-morning, randomly collected, and 24-h samples of urine from 53 healthy individuals (14 men and 39 women). The urines were collected once a week for 10 weeks. The data obtained were used as a basis for specimen collection and to gain insight into the influence of urine quantities in the diagnosis, screening, and monitoring of patients. We found that 24-h urine expressed in output rather than concentration units is the most reliable specimen for diagnosis and monitoring for most of the analytes studied. On the basis of the ratio between estimated within- and between-subject variation, the tests with greatest medical usefulness for diagnosis and screening of specific pathologies are those measuring protein and sodium. Moreover, the results indicate that urine creatinine may be a poor test for diagnosis, monitoring, and screening.
The following articles in journals at HighWire Press have cited this article:
![]() |
V. E. Torres, L. Bankir, and J. J. Grantham A Case for Water in the Treatment of Polycystic Kidney Disease Clin. J. Am. Soc. Nephrol., June 1, 2009; 4(6): 1140 - 1150. [Abstract] [Full Text] [PDF] |
||||
![]() |
O. T.M. Chan and D. A. Herold Chip Electrophoresis as a Method for Quantifying Total Microalbuminuria Clin. Chem., November 1, 2006; 52(11): 2141 - 2146. [Abstract] [Full Text] [PDF] |
||||
![]() |
K.-H. Yu, S.-F. Luo, W.-P. Tsai, and Y.-Y. Huang Intermittent elevation of serum urate and 24-hour urinary uric acid excretion Rheumatology, December 1, 2004; 43(12): 1541 - 1545. [Abstract] [Full Text] [PDF] |
||||
![]() |
A. H. GARDE, A. M. HANSEN, J. KRISTIANSEN, and L. E. KNUDSEN Comparison of Uncertainties Related to Standardization of Urine Samples with Volume and Creatinine Concentration Ann. Hyg., March 1, 2004; 48(2): 171 - 179. [Abstract] [Full Text] [PDF] |
||||
![]() |
H. W. Vesper, L. M. Demers, R. Eastell, P. Garnero, M. Kleerekoper, S. P. Robins, A. K. Srivastava, G. R. Warnick, N. B. Watts, and G. L. Myers Assessment and Recommendations on Factors Contributing to Preanalytical Variability of Urinary Pyridinoline and Deoxypyridinoline Clin. Chem., February 1, 2002; 48(2): 220 - 235. [Abstract] [Full Text] [PDF] |
||||
| HOME | HELP | FEEDBACK | SUBSCRIPTIONS | ARCHIVE | SEARCH | TABLE OF CONTENTS |