Clinical Chemistry
HOME HELP FEEDBACK SUBSCRIPTIONS ARCHIVE SEARCH TABLE OF CONTENTS
 QUICK SEARCH:   [advanced]


     


Clinical Chemistry 40: 472-477, 1994;
This Article
Right arrow Full Text (PDF)
Right arrow Alert me when this article is cited
Right arrow Alert me if a correction is posted
Right arrow Citation Map
Services
Right arrow Email this article to a friend
Right arrow Similar articles in this journal
Right arrow Similar articles in PubMed
Right arrow Alert me to new issues of the journal
Right arrow Download to citation manager
Right arrow reprints & permissions
Citing Articles
Right arrow Citing Articles via HighWire
Right arrow Citing Articles via Google Scholar
Google Scholar
Right arrow Articles by Ricos, C.
Right arrow Articles by Macia, M.
Right arrow Search for Related Content
PubMed
Right arrow PubMed Citation
Right arrow Articles by Ricos, C.
Right arrow Articles by Macia, M.

Clinical Chemistry, Vol 40, 472-477, Copyright © 1994 by American Association for Clinical Chemistry

Biological variation in urine samples used for analyte measurements

C Ricos, CV Jimenez, A Hernandez, M Simon, C Perich, V Alvarez, J Minchinela and M Macia
General Hospital Vall d'Hebron, Barcelona, Spain.

To determine the influence of biological variation on the reliability of data from different types of urine specimens, we measured nine analytes in first-morning, randomly collected, and 24-h samples of urine from 53 healthy individuals (14 men and 39 women). The urines were collected once a week for 10 weeks. The data obtained were used as a basis for specimen collection and to gain insight into the influence of urine quantities in the diagnosis, screening, and monitoring of patients. We found that 24-h urine expressed in output rather than concentration units is the most reliable specimen for diagnosis and monitoring for most of the analytes studied. On the basis of the ratio between estimated within- and between-subject variation, the tests with greatest medical usefulness for diagnosis and screening of specific pathologies are those measuring protein and sodium. Moreover, the results indicate that urine creatinine may be a poor test for diagnosis, monitoring, and screening.


The following articles in journals at HighWire Press have cited this article:


Home page
CJASNHome page
V. E. Torres, L. Bankir, and J. J. Grantham
A Case for Water in the Treatment of Polycystic Kidney Disease
Clin. J. Am. Soc. Nephrol., June 1, 2009; 4(6): 1140 - 1150.
[Abstract] [Full Text] [PDF]


Home page
Clin. Chem.Home page
O. T.M. Chan and D. A. Herold
Chip Electrophoresis as a Method for Quantifying Total Microalbuminuria
Clin. Chem., November 1, 2006; 52(11): 2141 - 2146.
[Abstract] [Full Text] [PDF]


Home page
Rheumatology (Oxford)Home page
K.-H. Yu, S.-F. Luo, W.-P. Tsai, and Y.-Y. Huang
Intermittent elevation of serum urate and 24-hour urinary uric acid excretion
Rheumatology, December 1, 2004; 43(12): 1541 - 1545.
[Abstract] [Full Text] [PDF]


Home page
ANN OCCUP HYGHome page
A. H. GARDE, A. M. HANSEN, J. KRISTIANSEN, and L. E. KNUDSEN
Comparison of Uncertainties Related to Standardization of Urine Samples with Volume and Creatinine Concentration
Ann. Hyg., March 1, 2004; 48(2): 171 - 179.
[Abstract] [Full Text] [PDF]


Home page
Clin. Chem.Home page
H. W. Vesper, L. M. Demers, R. Eastell, P. Garnero, M. Kleerekoper, S. P. Robins, A. K. Srivastava, G. R. Warnick, N. B. Watts, and G. L. Myers
Assessment and Recommendations on Factors Contributing to Preanalytical Variability of Urinary Pyridinoline and Deoxypyridinoline
Clin. Chem., February 1, 2002; 48(2): 220 - 235.
[Abstract] [Full Text] [PDF]




HOME HELP FEEDBACK SUBSCRIPTIONS ARCHIVE SEARCH TABLE OF CONTENTS
Copyright © 1994 by the American Association for Clinical Chemistry.