Clinical Chemistry, Vol 40, 625-629, Copyright © 1994 by American Association for Clinical Chemistry
JM Simo, J Joven, X Cliville and T Sans
Centre de Recerca Biomedica, Hospital de Sant Joan de Reus, Spain.
A considerable demand for convenient, rapid, inexpensive assays of ferritin in serum has been generated in recent years in hospital laboratories and blood banks. We describe a simple and rapid particle- enhanced turbidimetric immunoassay suitable for routine application in a Monarch 2000 centrifugal analyzer with commercially available reagents. This fully automated assay (y) requires no pretreatment of sample, and correlation with a two-step sandwich ELISA (x) is excellent (y = 1.018x + 0.397, Sy/x = 0.027). The analytical range extends from 5 to 900 micrograms/L. Intraassay imprecision (CV) ranged from 1.1% to 5% for various specimen concentrations. Interassay imprecision ranged from 2.2% for above-normal concentrations (755 micrograms/L) to 9.5% for low concentrations (39 micrograms/L). No specimen-related carryover was detected. The method has been useful in our predeposit autologous blood transfusion program for rapid assessment of iron status in patients undergoing repeated phlebotomies.
The following articles in journals at HighWire Press have cited this article:
![]() |
H. Wang, Y. Zhang, B. Yan, L. Liu, S. Wang, G. Shen, and R. Yu Rapid, Simple, and Sensitive Immunoagglutination Assay with SiO2 Particles and Quartz Crystal Microbalance for Quantifying Schistosoma japonicum Antibodies Clin. Chem., November 1, 2006; 52(11): 2065 - 2071. [Abstract] [Full Text] [PDF] |
||||
![]() |
P. Englebienne, A. Van Hoonacker, and J. Valsamis Rapid Homogeneous Immunoassay for Human Ferritin in the Cobas Mira Using Colloidal Gold as the Reporter Reagent Clin. Chem., December 1, 2000; 46(12): 2000 - 2003. [Full Text] [PDF] |
||||
![]() |
S. Guaita, J. M. Simo, N. Ferre, J. Joven, and J. Camps Evaluation of a Particle-enhanced Turbidimetric Immunoassay for the Measurement of Immunoglobulin E in an ILab 900 Analyzer Clin. Chem., September 1, 1999; 45(9): 1557 - 1561. [Abstract] [Full Text] [PDF] |
||||
![]() |
J. M a Simo, I. Castellano, N. Ferre, J. Joven, and J. Camps Evaluation of a homogeneous assay for high-density lipoprotein cholesterol: limitations in patients with cardiovascular, renal, and hepatic disorders Clin. Chem., June 1, 1998; 44(6): 1233 - 1241. [Abstract] [Full Text] [PDF] |
||||
![]() |
J. Joven, X. Cliville, J. Camps, E. Espinel, J. Simo, E. Vilella, and A. Oliver Plasma protein abnormalities in nephrotic syndrome: effect on plasma colloid osmotic pressure and viscosity Clin. Chem., July 1, 1997; 43(7): 1223 - 1231. [Abstract] [Full Text] [PDF] |
||||
| HOME | HELP | FEEDBACK | SUBSCRIPTIONS | ARCHIVE | SEARCH | TABLE OF CONTENTS |