Clinical Chemistry
HOME HELP FEEDBACK SUBSCRIPTIONS ARCHIVE SEARCH TABLE OF CONTENTS
 QUICK SEARCH:   [advanced]


     


Clinical Chemistry 40: 625-629, 1994;
This Article
Right arrow Full Text (PDF)
Right arrow Alert me when this article is cited
Right arrow Alert me if a correction is posted
Right arrow Citation Map
Services
Right arrow Email this article to a friend
Right arrow Similar articles in this journal
Right arrow Similar articles in PubMed
Right arrow Alert me to new issues of the journal
Right arrow Download to citation manager
Right arrow reprints & permissions
Citing Articles
Right arrow Citing Articles via HighWire
Right arrow Citing Articles via Google Scholar
Google Scholar
Right arrow Articles by Simo, J. M.
Right arrow Articles by Sans, T.
Right arrow Search for Related Content
PubMed
Right arrow PubMed Citation
Right arrow Articles by Simo, J. M.
Right arrow Articles by Sans, T.

Clinical Chemistry, Vol 40, 625-629, Copyright © 1994 by American Association for Clinical Chemistry

Automated latex agglutination immunoassay of serum ferritin with a centrifugal analyzer

JM Simo, J Joven, X Cliville and T Sans
Centre de Recerca Biomedica, Hospital de Sant Joan de Reus, Spain.

A considerable demand for convenient, rapid, inexpensive assays of ferritin in serum has been generated in recent years in hospital laboratories and blood banks. We describe a simple and rapid particle- enhanced turbidimetric immunoassay suitable for routine application in a Monarch 2000 centrifugal analyzer with commercially available reagents. This fully automated assay (y) requires no pretreatment of sample, and correlation with a two-step sandwich ELISA (x) is excellent (y = 1.018x + 0.397, Sy/x = 0.027). The analytical range extends from 5 to 900 micrograms/L. Intraassay imprecision (CV) ranged from 1.1% to 5% for various specimen concentrations. Interassay imprecision ranged from 2.2% for above-normal concentrations (755 micrograms/L) to 9.5% for low concentrations (39 micrograms/L). No specimen-related carryover was detected. The method has been useful in our predeposit autologous blood transfusion program for rapid assessment of iron status in patients undergoing repeated phlebotomies.


The following articles in journals at HighWire Press have cited this article:


Home page
Clin. Chem.Home page
H. Wang, Y. Zhang, B. Yan, L. Liu, S. Wang, G. Shen, and R. Yu
Rapid, Simple, and Sensitive Immunoagglutination Assay with SiO2 Particles and Quartz Crystal Microbalance for Quantifying Schistosoma japonicum Antibodies
Clin. Chem., November 1, 2006; 52(11): 2065 - 2071.
[Abstract] [Full Text] [PDF]


Home page
Clin. Chem.Home page
P. Englebienne, A. Van Hoonacker, and J. Valsamis
Rapid Homogeneous Immunoassay for Human Ferritin in the Cobas Mira Using Colloidal Gold as the Reporter Reagent
Clin. Chem., December 1, 2000; 46(12): 2000 - 2003.
[Full Text] [PDF]


Home page
Clin. Chem.Home page
S. Guaita, J. M. Simo, N. Ferre, J. Joven, and J. Camps
Evaluation of a Particle-enhanced Turbidimetric Immunoassay for the Measurement of Immunoglobulin E in an ILab 900 Analyzer
Clin. Chem., September 1, 1999; 45(9): 1557 - 1561.
[Abstract] [Full Text] [PDF]


Home page
Clin. Chem.Home page
J. M a Simo, I. Castellano, N. Ferre, J. Joven, and J. Camps
Evaluation of a homogeneous assay for high-density lipoprotein cholesterol: limitations in patients with cardiovascular, renal, and hepatic disorders
Clin. Chem., June 1, 1998; 44(6): 1233 - 1241.
[Abstract] [Full Text] [PDF]


Home page
Clin. Chem.Home page
J. Joven, X. Cliville, J. Camps, E. Espinel, J. Simo, E. Vilella, and A. Oliver
Plasma protein abnormalities in nephrotic syndrome: effect on plasma colloid osmotic pressure and viscosity
Clin. Chem., July 1, 1997; 43(7): 1223 - 1231.
[Abstract] [Full Text] [PDF]




HOME HELP FEEDBACK SUBSCRIPTIONS ARCHIVE SEARCH TABLE OF CONTENTS
Copyright © 1994 by the American Association for Clinical Chemistry.