Clinical Chemistry
HOME HELP FEEDBACK SUBSCRIPTIONS ARCHIVE SEARCH TABLE OF CONTENTS
 QUICK SEARCH:   [advanced]


     


Clinical Chemistry 40: 781-784, 1994;
This Article
Right arrow Full Text (PDF)
Right arrow Alert me when this article is cited
Right arrow Alert me if a correction is posted
Services
Right arrow Email this article to a friend
Right arrow Similar articles in this journal
Right arrow Similar articles in PubMed
Right arrow Alert me to new issues of the journal
Right arrow Download to citation manager
Right arrow reprints & permissions
Citing Articles
Right arrow Citing Articles via HighWire
Right arrow Citing Articles via Google Scholar
Google Scholar
Right arrow Articles by Kayamori, Y.
Right arrow Articles by Katayama, Y.
Right arrow Search for Related Content
PubMed
Right arrow PubMed Citation
Right arrow Articles by Kayamori, Y.
Right arrow Articles by Katayama, Y.

Clinical Chemistry, Vol 40, 781-784, Copyright © 1994 by American Association for Clinical Chemistry

Enzymatic method for assaying calcium in serum and urine with porcine pancreatic alpha-amylase

Y Kayamori and Y Katayama
Department of Clinical Chemistry, National Cardiovascular Center, Osaka, Japan.

We developed a kinetic assay for calcium in serum and urine, based on the activation of porcine pancreatic alpha-amylase (EC 3.2.1.1) with 2- chloro-4-nitrophenyl-alpha-maltotrioside as substrate. The kinetic generation of 2-chloro-4-nitrophenol, monitored at 405 nm, was proportional to the concentration of calcium in serum and urine. The assay was developed and evaluated with the Cobas Bio centrifugal analyzer. The average within-run and between-day imprecision (CV) was 0.96/1.26% and 1.07/1.63%, respectively, for serum calcium and 1.50/2.54% and 1.70/2.64%, respectively, for urine calcium. Results of the proposed method (y) correlated well with those determined by atomic absorption spectrophotometry (x): y(serum) = 1.005x + 0.028 mmol/L (Sy/x = 0.058, r = 0.974, n = 50), and y(urine) = 1.017x-0.115 mmol/L Sy/x = 0.30, r = 0.981, n = 25). We also present data showing that the method is highly sensitive, rapid, relatively free of interference, and amenable to automation.


The following articles in journals at HighWire Press have cited this article:


Home page
Ann Clin BiochemHome page
E. Hokazono, S. Osawa, T. Nakano, Y. Kawamoto, Y. Oguchi, T. Hotta, Y. Kayamori, D. Kang, Y. Cho, K. Shiba, et al.
Development of a new measurement method for serum calcium with chlorophosphonazo-III
Ann Clin Biochem, July 1, 2009; 46(4): 296 - 301.
[Abstract] [Full Text] [PDF]


Home page
Clin. Chem.Home page
M. Sugano, K. Yamauchi, K. Sugano, K. Kawasaki, M. Tozuka, T. Katsuyama, H. Soya, T. Tanaka, S. Imamura, and S. Nomoto
New Enzymatic Assay Using Phospholipase D to Measure Total Calcium in Serum
Clin. Chem., June 1, 2005; 51(6): 1021 - 1024.
[Full Text] [PDF]


Home page
Clin. Chem.Home page
Y. Morishita, Y. Iinuma, N. Nakashima, A. Kadota, A. Miike, and T. Tadano
Enzymatic Assay of Calcium in Serum with Phospholipase D
Clin. Chem., December 1, 1999; 45(12): 2280 - 2283.
[Full Text] [PDF]