Clinical Chemistry
HOME HELP FEEDBACK SUBSCRIPTIONS ARCHIVE SEARCH TABLE OF CONTENTS
 QUICK SEARCH:   [advanced]


     


Clinical Chemistry 41: 1649-1653, 1995;
This Article
Right arrow Full Text (PDF)
Right arrow Alert me when this article is cited
Right arrow Alert me if a correction is posted
Services
Right arrow Email this article to a friend
Right arrow Similar articles in this journal
Right arrow Similar articles in PubMed
Right arrow Alert me to new issues of the journal
Right arrow Download to citation manager
Right arrow reprints & permissions
Citing Articles
Right arrow Citing Articles via HighWire
Right arrow Citing Articles via Google Scholar
Google Scholar
Right arrow Articles by Hristova, E. N.
Right arrow Articles by Elin, R. J.
Right arrow Search for Related Content
PubMed
Right arrow PubMed Citation
Right arrow Articles by Hristova, E. N.
Right arrow Articles by Elin, R. J.

Clinical Chemistry, Vol 41, 1649-1653, Copyright © 1995 by American Association for Clinical Chemistry

Analyzer-dependent differences in results for ionized calcium, ionized magnesium, sodium, and pH

EN Hristova, S Cecco, JE Niemela, NN Rehak and RJ Elin
Clinical Pathology Department, Warren Grant Magnuson Clinical Center, National Institutes of Health, Bethesda, MD 20892, USA.

We compared two ion-selective analyzers (AVL 988-4 and NOVA CRT) for determining ionized calcium (iCa2+), ionized magnesium (iMg2+), sodium (Na+), and pH in serum specimens from healthy and diseased individuals. For assays of three levels of protein-based control materials, total imprecision (CV) was < 3% for all analytes except iMg2+ (< or = 6.5% on NOVA, and < or = 4.9% on AVL). We found a significant difference between the analyzers (P < 0.001) for the mean iMg2+ concentration in patients but no significant correlation (r = 0.253) between the analyzers for iMg2+ in specimens from healthy volunteers, even though the mean iMg2+ concentration did not differ significantly between these groups. The reference interval (central 95 percentiles) for iMg2+ with AVL (0.44-0.60 mmol/L) was contained within that of NOVA (0.39-0.64 mmol/L). The AVL gave higher values for iCa2+ (P < 0.001) and lower values for pH (P < 0.001) in specimens from normal volunteers and patients. The mean value for Na+ in patients' samples was significantly higher by the NOVA (P < 0.01) than by the AVL analyzer. Thus, we found significant differences between these two analyzers for all four analytes.


The following articles in journals at HighWire Press have cited this article:


Home page
Clin. Chem.Home page
F. Zoppi and C. Cristalli
Ionized Magnesium in Serum and Ultrafiltrate: pH and Bicarbonate Effect on Measurements with the AVL 988-4 Electrolyte Analyzer
Clin. Chem., March 1, 1998; 44(3): 668 - 671.
[Full Text] [PDF]


Home page
Clin. Chem.Home page
N. N. Rehak, S. A. Cecco, J. E. Niemela, and R. J. Elin
Thiocyanate in smokers interferes with the Nova magnesium ion-selective electrode
Clin. Chem., September 1, 1997; 43(9): 1595 - 1600.
[Abstract] [Full Text] [PDF]


Home page
Clin. Chem.Home page
E. N. Hristova, N. N. Rehak, S. Cecco, M. Ruddel, D. Herion, M. Eckardt, M. Linnoila, and R. J. Elin
Serum ionized magnesium in chronic alcoholism: is it really decreased?
Clin. Chem., February 1, 1997; 43(2): 394 - 399.
[Abstract] [Full Text] [PDF]




HOME HELP FEEDBACK SUBSCRIPTIONS ARCHIVE SEARCH TABLE OF CONTENTS
Copyright © 1995 by the American Association for Clinical Chemistry.