Clinical Chemistry AACC Online Job Center
HOME HELP FEEDBACK SUBSCRIPTIONS ARCHIVE SEARCH TABLE OF CONTENTS
 QUICK SEARCH:   [advanced]


     


Clinical Chemistry 41: 1730-1737, 1995;
This Article
Right arrow Order Full text via Infotrieve
Right arrow Submit an electronic Letter to
the Editor about this paper
Right arrow Alert me when this article is cited
Right arrow Alert me when eLetters are posted
Right arrow Alert me if a correction is posted
Services
Right arrow Email this article to a friend
Right arrow Similar articles in this journal
Right arrow Similar articles in PubMed
Right arrow Alert me to new issues of the journal
Right arrow Download to citation manager
Right arrow reprints & permissions
Citing Articles
Right arrow Citing Articles via HighWire
Right arrow Citing Articles via Google Scholar
Google Scholar
Right arrow Articles by Wener, M. H.
Right arrow Articles by Brawer, M. K.
Right arrow Search for Related Content
PubMed
Right arrow PubMed Citation
Right arrow Articles by Wener, M. H.
Right arrow Articles by Brawer, M. K.

Clinical Chemistry, Vol 41, 1730-1737, Copyright © 1995 by American Association for Clinical Chemistry

Variation in measurement of prostate-specific antigen: importance of method and lot variability

MH Wener, PR Daum and MK Brawer
Department of Laboratory Medicine, University of Washington Medical Center, Seattle 98195, USA.

Equivalence between Hybritech Tandem and Abbott IMx PSA methods have been reported by some but not all previous investigators. To determine reasons for these differing conclusions, we measured serum PSA with three different lots each of IMx and Tandem-E kits. Overall, mean IMx results were significantly lower than Tandem-E results; however, for selected sera, the IMx results were consistently higher than the Tandem- E results. Lot-to-lot differences for the IMx method were significantly greater than those with the Tandem-E method. Most IMx/Tandem-E lot-to- lot comparisons had linear regression slopes that differed significantly from 1.0, but some did not. Conclusions concerning the equivalence of the IMx and the Tandem-E methods can be influenced both by variations in the proportions of free PSA in sera in tested populations and by lot-to-lot differences in the IMx method.


The following articles in journals at HighWire Press have cited this article:


Home page
Clin. Chem.Home page
A. W. Roddam, C. P. Price, N. E. Allen, and A. M. Ward
Assessing the Clinical Impact of Prostate-Specific Antigen Assay Variability and Nonequimolarity: A Simulation Study Based on the Population of the United Kingdom
Clin. Chem., June 1, 2004; 50(6): 1012 - 1016.
[Abstract] [Full Text] [PDF]


Home page
Clin. Chem.Home page
A. Semjonow, F. Oberpenning, C. Weining, M. Schon, B. Brandt, G. De Angelis, A. Heinecke, M. Hamm, P. Stieber, L. Hertle, et al.
Do Modifications of Nonequimolar Assays for Total Prostate-specific Antigen Improve Detection of Prostate Cancer?
Clin. Chem., August 1, 2001; 47(8): 1472 - 1475.
[Full Text] [PDF]


Home page
Clin. Chem.Home page
M. Gion, R. Mione, P. Barioli, M. Barichello, F. Zattoni, T. Prayer-Galetti, M. Plebani, G. Aimo, C. Terrone, F. Manferrari, et al.
Percent free prostate-specific antigen in assessing the probability of prostate cancer under optimal analytical conditions
Clin. Chem., December 1, 1998; 44(12): 2462 - 2470.
[Abstract] [Full Text] [PDF]


Home page
Clin. Chem.Home page
C. D. Cheli, M. Marcus, J. Levine, Z. Zhou, P. H. Anderson, D. D. Bankson, J. Bock, S. Bodin, C. Eisen, M. Senior, et al.
Variation in the Quantitation of Prostate-specific Antigen in Reference Material: Differences in Commercial Immunoassays,
Clin. Chem., July 1, 1998; 44(7): 1551 - 1553.
[Full Text] [PDF]




HOME HELP FEEDBACK SUBSCRIPTIONS ARCHIVE SEARCH TABLE OF CONTENTS
Copyright © 1995 by the American Association for Clinical Chemistry.