Clinical Chemistry
HOME HELP FEEDBACK SUBSCRIPTIONS ARCHIVE SEARCH TABLE OF CONTENTS
 QUICK SEARCH:   [advanced]


     


Clinical Chemistry 41: 300-305, 1995;
This Article
Right arrow Full Text (PDF)
Right arrow Alert me when this article is cited
Right arrow Alert me if a correction is posted
Services
Right arrow Email this article to a friend
Right arrow Similar articles in this journal
Right arrow Similar articles in PubMed
Right arrow Alert me to new issues of the journal
Right arrow Download to citation manager
Right arrow reprints & permissions
Citing Articles
Right arrow Citing Articles via HighWire
Right arrow Citing Articles via Google Scholar
Google Scholar
Right arrow Articles by Livesey, J. F.
Right arrow Articles by Maddock, M. J.
Right arrow Search for Related Content
PubMed
Right arrow PubMed Citation
Right arrow Articles by Livesey, J. F.
Right arrow Articles by Maddock, M. J.

Clinical Chemistry, Vol 41, 300-305, Copyright © 1995 by American Association for Clinical Chemistry

Simultaneous determination of alcohols and ethylene glycol in serum by packed- or capillary-column gas chromatography

JF Livesey, SL Perkins, NE Tokessy and MJ Maddock
Department of Laboratory Medicine, Ottawa Civic Hospital, Ontario, Canada.

We developed a packed-column chromatographic procedure capable of simultaneous quantitation of methanol, ethanol, isopropanol, acetone, and ethylene glycol. This method was then updated to a rapid, sensitive, wide-bore capillary method. The packed-column system uses direct injection of 1 microL of Na2WO4/H2SO4-deproteinized serum onto a 1.8 m x 2 mm (i.d.) column packed with 80/100 HayeSep R. A linear temperature gradient from 90 to 205 degrees C allows complete elution of all components within 20 min; minimum detection limits are 2 mmol/L. The wide-bore capillary method uses 0.1 microL of sample deproteinized by ultrafiltration, injected onto a 30 m x 0.53 mm (i.d.) 3-microns Rtx- 200 (Restek) column. Baseline resolution to a minimum detection limit of 0.1 mmol/L of all compounds is achieved in 5 min with a linear temperature gradient from 40 to 250 degrees C and dual internal standards of n-propanol and 1,2-butanediol.


The following articles in journals at HighWire Press have cited this article:


Home page
Appl. Environ. Microbiol.Home page
J. Xue, C. M. Murrieta, D. C. Rule, and K. W. Miller
Exogenous or L-Rhamnose-Derived 1,2-Propanediol Is Metabolized via a pduD-Dependent Pathway in Listeria innocua
Appl. Envir. Microbiol., November 15, 2008; 74(22): 7073 - 7079.
[Abstract] [Full Text] [PDF]


Home page
Clin. Chem.Home page
A. F. Eder, C. M. McGrath, Y. G. Dowdy, J. E. Tomaszewski, F. M. Rosenberg, R. B. Wilson, B. A. Wolf, and L. M. Shaw
Ethylene glycol poisoning: toxicokinetic and analytical factors affecting laboratory diagnosis
Clin. Chem., January 1, 1998; 44(1): 168 - 177.
[Abstract] [Full Text] [PDF]


Home page
Clin. Chem.Home page
A. Tangerman
Highly sensitive gas chromatographic analysis of ethanol in whole blood, serum, urine, and fecal supernatants by the direct injection method
Clin. Chem., June 1, 1997; 43(6): 1003 - 1009.
[Abstract] [Full Text] [PDF]




HOME HELP FEEDBACK SUBSCRIPTIONS ARCHIVE SEARCH TABLE OF CONTENTS
Copyright © 1995 by the American Association for Clinical Chemistry.