Clinical Chemistry Link to Randox Laboratories Web Site
HOME HELP FEEDBACK SUBSCRIPTIONS ARCHIVE SEARCH TABLE OF CONTENTS
 QUICK SEARCH:   [advanced]


     


Clinical Chemistry 41: 397-404, 1995;
This Article
Right arrow Full Text (PDF)
Right arrow Submit an electronic Letter to
the Editor about this paper
Right arrow Alert me when this article is cited
Right arrow Alert me when eLetters are posted
Right arrow Alert me if a correction is posted
Services
Right arrow Email this article to a friend
Right arrow Similar articles in this journal
Right arrow Similar articles in PubMed
Right arrow Alert me to new issues of the journal
Right arrow Download to citation manager
Right arrow reprints & permissions
Citing Articles
Right arrow Citing Articles via HighWire
Right arrow Citing Articles via Google Scholar
Google Scholar
Right arrow Articles by Ellerbe, P.
Right arrow Articles by Welch, M. J.
Right arrow Search for Related Content
PubMed
Right arrow PubMed Citation
Right arrow Articles by Ellerbe, P.
Right arrow Articles by Welch, M. J.

Clinical Chemistry, Vol 41, 397-404, Copyright © 1995 by American Association for Clinical Chemistry

Isotope dilution mass spectrometry as a candidate definitive method for determining total glycerides and triglycerides in serum

P Ellerbe, LT Sniegoski and MJ Welch
National Institute of Standards and Technology, Gaithersburg, MD 20899.

A new isotope dilution mass spectrometric method for total glycerides and triglycerides in human serum is described. Total glycerides are defined as the sum of tri-, di-, and monoglycerides plus free glycerol; triglycerides are defined as the pure triglyceride species. In both determinations, serum samples are supplemented by addition of [13C3]tripalmitin, processed, derivatized, and the abundance ratios of selected ions are determined. Bias is investigated by quantifying the analyte in the same samples under different chromatographic and ionization conditions. The analytes were determined in two human serum pools. The CV for a single measurement ranged from 0.35% to 0.72%, and the relative SEM ranged from 0.10% to 0.34%; there was no significant bias in the measurements. The combination of high precision and absence of significant bias in the results qualify this method for consideration as a Definitive Method as defined by the National Committee for Clinical Laboratory Standards.


The following articles in journals at HighWire Press have cited this article:


Home page
J. Lipid Res.Home page
H. Li, J. Dong, W. Chen, S. Wang, H. Guo, Y. Man, P. Mo, and J. Li
Measurement of serum total glycerides and free glycerol by high-performance liquid chromatography
J. Lipid Res., September 1, 2006; 47(9): 2089 - 2096.
[Abstract] [Full Text] [PDF]


Home page
Clin. Chem.Home page
A. M. Gotto and G. R. Cooper
Citation Classics in Lipid Measurement and Applications
Clin. Chem., November 1, 1998; 44(11): 2234 - 2237.
[Full Text] [PDF]


Home page
Clin. Chem.Home page
J. R. McNamara, E. T. Leary, F. Ceriotti, C. M. Boersma-Cobbaert, T. G. Cole, D. J. Hassemer, M. Nakamura, C. J. Packard, D. W. Seccombe, M. M. Kimberly, et al.
Point Status of lipid and lipoprotein standardization
Clin. Chem., August 1, 1997; 43(8): 1306 - 1310.
[Abstract] [Full Text] [PDF]




HOME HELP FEEDBACK SUBSCRIPTIONS ARCHIVE SEARCH TABLE OF CONTENTS
Copyright © 1995 by the American Association for Clinical Chemistry.