Clinical Chemistry
HOME HELP FEEDBACK SUBSCRIPTIONS ARCHIVE SEARCH TABLE OF CONTENTS
 QUICK SEARCH:   [advanced]


     


Clinical Chemistry 41: 435-438, 1995;
This Article
Right arrow Full Text (PDF)
Right arrow Alert me when this article is cited
Right arrow Alert me if a correction is posted
Services
Right arrow Email this article to a friend
Right arrow Similar articles in this journal
Right arrow Similar articles in PubMed
Right arrow Alert me to new issues of the journal
Right arrow Download to citation manager
Right arrow reprints & permissions
Citing Articles
Right arrow Citing Articles via HighWire
Right arrow Citing Articles via Google Scholar
Google Scholar
Right arrow Articles by Gubern, G.
Right arrow Articles by Gella, F. J.
Right arrow Search for Related Content
PubMed
Right arrow PubMed Citation
Right arrow Articles by Gubern, G.
Right arrow Articles by Gella, F. J.

Clinical Chemistry, Vol 41, 435-438, Copyright © 1995 by American Association for Clinical Chemistry

Determination of alpha-amylase activity: methods comparison and commutability study of several control materials

G Gubern, F Canalias and FJ Gella
Departament de Bioquimica i Biologia Molecular, Universitat Autonoma de Barcelona, Spain.

Six different methods for alpha-amylase determination were compared by assaying human serum samples covering a wide range of alpha-amylase values. All the methods studied use as substrate a maltooligosaccharide with a chromophore group at the reducing end; some are chemically blocked at the nonreducing end. Intermethod comparison by regression and correspondence analyses showed significant differences for two methods. The commutability of 12 commercial control materials containing alpha-amylase was also assessed by the different methods in comparison with human serum specimens containing the pancreatic and salivary isoenzymes. We also studied the behavior of pancreatic and salivary materials prepared in our laboratory. Control materials with alpha-amylase of non-human origin were not commutable with the enzyme in human sera and should not be used for intermethod calibration.


The following articles in journals at HighWire Press have cited this article:


Home page
Clin. Chem.Home page
A. Mosca, R. Paleari, A. Made, C. Ferrero, M. Locatelli, and F. Ceriotti
Commutability of control materials in glycohemoglobin determinations
Clin. Chem., March 1, 1998; 44(3): 632 - 638.
[Abstract] [Full Text] [PDF]




HOME HELP FEEDBACK SUBSCRIPTIONS ARCHIVE SEARCH TABLE OF CONTENTS
Copyright © 1995 by the American Association for Clinical Chemistry.