Clinical Chemistry
HOME HELP FEEDBACK SUBSCRIPTIONS ARCHIVE SEARCH TABLE OF CONTENTS
 QUICK SEARCH:   [advanced]


     


Clinical Chemistry 41: 591-598, 1995;
This Article
Right arrow Full Text (PDF)
Right arrow Alert me when this article is cited
Right arrow Alert me if a correction is posted
Services
Right arrow Email this article to a friend
Right arrow Similar articles in this journal
Right arrow Similar articles in PubMed
Right arrow Alert me to new issues of the journal
Right arrow Download to citation manager
Right arrow reprints & permissions
Citing Articles
Right arrow Citing Articles via HighWire
Right arrow Citing Articles via Google Scholar
Google Scholar
Right arrow Articles by Yao, H.
Right arrow Articles by Jenkins, S. H.
Right arrow Search for Related Content
PubMed
Right arrow PubMed Citation
Right arrow Articles by Yao, H.
Right arrow Articles by Jenkins, S. H.

Clinical Chemistry, Vol 41, 591-598, Copyright © 1995 by American Association for Clinical Chemistry

Electrochemical dehydrogenase-based homogeneous assays in whole blood

H Yao, HB Halsall, WR Heineman and SH Jenkins
Biomedical Chemistry Research Center, University of Cincinnati, OH 45221-0172, USA.

An electrochemical method has been developed for determining NADH in whole blood for dehydrogenase-based assays by flow-injection analysis. NADH generated by dehydrogenase is oxidized by an electron-transfer coupling reagent, 2,6-dichloroindophenol (DCIP). The reduced form of DCIP (DCIPH2) is measured amperometrically by flow-injection analysis. Endogenous interferents were inhibited by p-hydroxymercuribenzoate. Electrode fouling by proteins was not observed under assay conditions. The Emit theophylline enzyme immunoassay and the hexokinase glucose assay were used as models. For the glucose assay, the intraassay CVs were 15% at 0.31 g/L and 3.5% at 1.82 g/L. Recoveries of glucose from whole blood (compared with that for aqueous standards) were 109%, 97.9%, and 101% at 0.050, 2.00, and 5.00 g/L glucose, respectively, and 104%, 101%, and 102% for theophylline at concentrations of 5.0 (low), 16.4 (medium), and 30.2 (high) mg/L, respectively, with corresponding precisions of 12%, 9.5%, and 8.8%. Both assays correlated well with results by reference methods. These studies demonstrate that this method can measure NADH in whole blood without prior separation and that it is potentially applicable to other dehydrogenase-based assays in whole blood.


The following articles in journals at HighWire Press have cited this article:


Home page
Clin. Chem.Home page
J. Wu, F. Yan, J. Tang, C. Zhai, and H. Ju
A Disposable Multianalyte Electrochemical Immunosensor Array for Automated Simultaneous Determination of Tumor Markers
Clin. Chem., August 1, 2007; 53(8): 1495 - 1502.
[Abstract] [Full Text] [PDF]




HOME HELP FEEDBACK SUBSCRIPTIONS ARCHIVE SEARCH TABLE OF CONTENTS
Copyright © 1995 by the American Association for Clinical Chemistry.