Clinical Chemistry Link to Randox Laboratories Web Site
HOME HELP FEEDBACK SUBSCRIPTIONS ARCHIVE SEARCH TABLE OF CONTENTS
 QUICK SEARCH:   [advanced]


     


Clinical Chemistry 41: 986-990, 1995;
This Article
Right arrow Full Text (PDF)
Right arrow Submit an electronic Letter to
the Editor about this paper
Right arrow Alert me when this article is cited
Right arrow Alert me when eLetters are posted
Right arrow Alert me if a correction is posted
Services
Right arrow Email this article to a friend
Right arrow Similar articles in this journal
Right arrow Similar articles in PubMed
Right arrow Alert me to new issues of the journal
Right arrow Download to citation manager
Right arrow reprints & permissions
Citing Articles
Right arrow Citing Articles via Google Scholar
Google Scholar
Right arrow Articles by Piran, U.
Right arrow Articles by Livshin, L. A.
Right arrow Search for Related Content
PubMed
Right arrow PubMed Citation
Right arrow Articles by Piran, U.
Right arrow Articles by Livshin, L. A.

Clinical Chemistry, Vol 41, 986-990, Copyright © 1995 by American Association for Clinical Chemistry

New noncompetitive immunoassays of small analytes

U Piran, WJ Riordan and LA Livshin
Ciba Corning Diagnostic Corp., Walpole, MA 02032, USA.

We developed a novel noncompetitive immunoassay format for monoepitopic analytes and describe here a model assay for triiodothyronine (T3), performed on Ciba Corning's ACS:180 analyzer. Acridinium ester (AE)- labeled bivalent anti-T3 was incubated with the sample, producing AE- anti-T3/T3 complexes and unreacted AE-anti-T3. Controlled-pore glass particles (CPG) with immobilized diiodothyronine (T2) were then added in excess, to bind AE-anti-T3 possessing two unoccupied binding sites but not AE-anti-T3 bound to one or two T3 molecules. Paramagnetic particles (PMP) with immobilized anti-AE were then added to the same cuvette to capture AE-anti-T3/T3 complexes; AE-anti-T3 bound to the surface of CPG, however, was not captured, because of steric hindrance. After the incubation, the PMP was magnetically separated to remove the liquid phase and the suspended CPG from the cuvette. The chemiluminescence associate with the PMP remaining in the cuvette was then measured. This noncompetitive T3 assay exhibited a 10-fold lower detection limit than the equivalent competitive T3 assay, i.e., 0.3 vs pg/test. Imprecision (CV) in the clinically significant range was 6% or less. The assay also displayed two- to sevenfold lower cross- reactivities and a wider dynamic range.