Clinical Chemistry
HOME HELP FEEDBACK SUBSCRIPTIONS ARCHIVE SEARCH TABLE OF CONTENTS
 QUICK SEARCH:   [advanced]


     


Clinical Chemistry 42: 1604-1608, 1996;
This Article
Right arrow Full Text (PDF)
Right arrow Alert me when this article is cited
Right arrow Alert me if a correction is posted
Services
Right arrow Email this article to a friend
Right arrow Similar articles in this journal
Right arrow Similar articles in PubMed
Right arrow Alert me to new issues of the journal
Right arrow Download to citation manager
Right arrow reprints & permissions
Citing Articles
Right arrow Citing Articles via HighWire
Right arrow Citing Articles via Google Scholar
Google Scholar
Right arrow Articles by Walker, G. T.
Right arrow Articles by Linn, C. P.
Right arrow Search for Related Content
PubMed
Right arrow PubMed Citation
Right arrow Articles by Walker, G. T.
Right arrow Articles by Linn, C. P.

Clinical Chemistry, Vol 42, 1604-1608, Copyright © 1996 by American Association for Clinical Chemistry

Detection of Mycobacterium tuberculosis DNA with thermophilic strand displacement amplification and fluorescence polarization

GT Walker and CP Linn
Becton Dickinson Research Center, Research Triangle Park, NC 27709- 2016, USA. walker@bdrc.bd.com

Strand displacement amplification (SDA) is an isothermal, in vitro method for diagnostics that amplifies a target DNA sequence by using a restriction enzyme and DNA polymerase. We have combined a new thermophilic form of SDA that involves restriction enzyme BsoBI and polymerase exo-Bca with fluorescence polarization for detection of Mycobacterium tuberculosis DNA by using the IS6110 insertion element as the target sequence. A 5'-fluorescein-labeled oligodeoxynucleotide detector probe hybridizes to the amplified product as it rises in concentration during SDA, and the single- to double-stranded conversion is monitored through an increase in fluorescence polarization. The associated change in polarization upon amplification of the target sequence is enhanced by specific polymerase binding to the double- stranded detector probe. Fewer than 10 M. tuberculosis genomes can be amplified and detected with an extremely simple protocol that takes only 20 min and uses relatively simple instrumentation and reagents, all of which can be purchased off-the-shelf.


The following articles in journals at HighWire Press have cited this article:


Home page
Nucleic Acids ResHome page
J. C. Samuelson, Z. Zhu, and S.-y. Xu
The isolation of strand-specific nicking endonucleases from a randomized SapI expression library
Nucleic Acids Res., July 9, 2004; 32(12): 3661 - 3671.
[Abstract] [Full Text] [PDF]


Home page
Genome ResHome page
X. Chen, L. Levine, and P.-Y. Kwok
Fluorescence Polarization in Homogeneous Nucleic Acid Analysis
Genome Res., May 1, 1999; 9(5): 492 - 498.
[Abstract] [Full Text]


Home page
Clin. Chem.Home page
L. J. Kricka
Nucleic Acid Detection Technologies — Labels, Strategies, and Formats
Clin. Chem., April 1, 1999; 45(4): 453 - 458.
[Abstract] [Full Text] [PDF]


Home page
Appl. Environ. Microbiol.Home page
R. Morgan, J.-p. Xiao, and S.-y. Xu
Characterization of an Extremely Thermostable Restriction Enzyme, PspGI, from a Pyrococcus Strain and Cloning of the PspGI Restriction-Modification System in Escherichia coli
Appl. Envir. Microbiol., October 1, 1998; 64(10): 3669 - 3673.
[Abstract] [Full Text]




HOME HELP FEEDBACK SUBSCRIPTIONS ARCHIVE SEARCH TABLE OF CONTENTS
Copyright © 1996 by the American Association for Clinical Chemistry.