Clinical Chemistry
HOME HELP FEEDBACK SUBSCRIPTIONS ARCHIVE SEARCH TABLE OF CONTENTS
 QUICK SEARCH:   [advanced]


     


Clinical Chemistry 42: 1654-1658, 1996;
This Article
Right arrow Full Text (PDF)
Right arrow Alert me when this article is cited
Right arrow Alert me if a correction is posted
Services
Right arrow Email this article to a friend
Right arrow Similar articles in this journal
Right arrow Similar articles in PubMed
Right arrow Alert me to new issues of the journal
Right arrow Download to citation manager
Right arrow reprints & permissions
Citing Articles
Right arrow Citing Articles via HighWire
Right arrow Citing Articles via Google Scholar
Google Scholar
Right arrow Articles by Jortani, S. A.
Right arrow Articles by Valdes, R.
Right arrow Search for Related Content
PubMed
Right arrow PubMed Citation
Right arrow Articles by Jortani, S. A.
Right arrow Articles by Valdes, R., Jr

Clinical Chemistry, Vol 42, 1654-1658, Copyright © 1996 by American Association for Clinical Chemistry

Inhibition of Na,K-ATPase by oleandrin and oleandrigenin, and their detection by digoxin immunoassays

SA Jortani, RA Helm and R Valdes Jr
Department of Pathology, University of Louisville School of Medicine, KY 40292, USA.

Ingestion of oleander plant, containing the cardiac glycoside oleandrin, has been reported to induce fatal poisonings. Derivatives of oleandrin are structurally similar to digoxin. We investigated the cross-reactivities of oleandrin and its aglycone metabolite, oleandrigenin, in several commercially available digoxin immunoassays; assessed their ability to inhibit Na,K-ATPase catalytic activity; and measured their binding to proteins in serum. As assayed with ACS:180, Stratus, RIA, On-Line, and TDx digoxin assays, oleandrin at 100 micromol/L in digoxin-free serum gave apparent digoxin values of 0, 0.83, 2.24, 2.37, and 5.34 nmol/L, respectively, whereas oleandrigenin at that concentration gave results of 0, 0.52, 0.77, 4.94, and 1.40 nmol/L. Study of Na,K-ATPase inhibition showed IC50 values (micromol/L) of 0.22 for ouabain, 0.62 for oleandrin, 1.23 for oleandrigenin, and 2.69 for digoxin. At 25 degrees C, 96% of oleandrin and 48% of oleandrigenin were bound to serum proteins. Because detection of oleandrin and oleandrigenin by digoxin immunoassays is variable between assays as well as between congeners, assessment of cross-reactivity is warranted for each assay. The inhibition of Na,K-ATPase by oleandrin and oleandrigenin confirms that they likely exert their toxic effects through inhibition of sodium pump activity. In cases of digitalis-like poisoning with suspicion of oleander ingestion, a combination of digoxin immunoassays may be useful to effectively rule out the presence of oleander.


The following articles in journals at HighWire Press have cited this article:


Home page
Cancer Res.Home page
S. K. Manna, N. K. Sah, R. A. Newman, A. Cisneros, and B. B. Aggarwal
Oleandrin Suppresses Activation of Nuclear Transcription Factor-{{kappa}}B, Activator Protein-1, and c-Jun NH2-Terminal Kinase
Cancer Res., July 1, 2000; 60(14): 3838 - 3847.
[Abstract] [Full Text]


Home page
Clin. Chem.Home page
R. Valdes Jr., S. A. Jortani, and M. Gheorghiade
Standards of laboratory practice: cardiac drug monitoring
Clin. Chem., May 1, 1998; 44(5): 1096 - 1109.
[Abstract] [Full Text] [PDF]




HOME HELP FEEDBACK SUBSCRIPTIONS ARCHIVE SEARCH TABLE OF CONTENTS
Copyright © 1996 by the American Association for Clinical Chemistry.