Clinical Chemistry 42: 1683-1688, 1996;
This Article
Right arrow Full Text (PDF)
Right arrow Alert me when this article is cited
Right arrow Alert me if a correction is posted
Services
Right arrow Email this article to a friend
Right arrow Similar articles in this journal
Right arrow Similar articles in PubMed
Right arrow Alert me to new issues of the journal
Right arrow Download to citation manager
Right arrow reprints & permissions
Citing Articles
Right arrow Citing Articles via HighWire
Right arrow Citing Articles via Google Scholar
Google Scholar
Right arrow Articles by Westgard, J. O.
Right arrow Articles by Boss, S.
Right arrow Search for Related Content
PubMed
Right arrow PubMed Citation
Right arrow Articles by Westgard, J. O.
Right arrow Articles by Boss, S.

Clinical Chemistry, Vol 42, 1683-1688, Copyright © 1996 by American Association for Clinical Chemistry

Design and assessment of average of normals (AON) patient data algorithms to maximize run lengths for automatic process control

JO Westgard, FA Smith, PJ Mountain and S Boss
Department of Pathology and Laboratory Medicine, University of Wisconsin Medical School, Madison 53792, USA.

Achieving high quality and high productivity with automated testing processes will require process control systems that are optimized for the necessary error detection, minimum false rejection, and maximum run length. This study investigates whether run length could be monitored by average of normals (AON) algorithms that truncate the patient test distribution and estimate the average of a suitable number of patient results. The design of AON algorithms for individual analytes is facilitated by computer-simulated power curves that consider the ratio of the population biological variation (Spop) to the test method variation (Smeas), represent a range of Spop/Smeas ratios from 2 to 15, and include numbers of patient test results from 10 to 600. The potential applications of AON algorithms are assessed for 38 tests whose quality requirements represent the total error criteria from the Ontario Medical Association Laboratory Proficiency Testing Program, Spop/Smeas ratios from 0 to 32, critical systematic shifts from 0.02 to 10.85 Smeas, and test workloads representative of a regional reference laboratory. Approximately half of these tests provide high potential for applying AON algorithms to monitor run length.


The following articles in journals at HighWire Press have cited this article:


Home page
Clin. Chem.Home page
A. Neubauer, C. Wolter, C. Falkner, and D. Neumeier
Optimizing frequency and number of controls for automatic multichannel analyzers
Clin. Chem., May 1, 1998; 44(5): 1014 - 1023.
[Abstract] [Full Text] [PDF]


Home page
Clin. Chem.Home page
G. S. Cembrowski
Thoughts on quality-control systems: a laboratorian's perspective
Clin. Chem., May 1, 1997; 43(5): 886 - 892.
[Abstract] [Full Text] [PDF]


Home page
Clin. Chem.Home page
J. O. Westgard and B. Stein
Automated Selection of Statistical Quality-Control Procedures to Assure Meeting Clinical or Analytical Quality Requirements
Clin. Chem., February 1, 1997; 43(2): 400 - 403.
[Full Text] [PDF]