Clinical Chemistry AACC Online Job Center
HOME HELP FEEDBACK SUBSCRIPTIONS ARCHIVE SEARCH TABLE OF CONTENTS
 QUICK SEARCH:   [advanced]


     


Clinical Chemistry 42: 258-262, 1996;
This Article
Right arrow Full Text (PDF)
Right arrow Submit an electronic Letter to
the Editor about this paper
Right arrow Alert me when this article is cited
Right arrow Alert me when eLetters are posted
Right arrow Alert me if a correction is posted
Services
Right arrow Email this article to a friend
Right arrow Similar articles in this journal
Right arrow Similar articles in PubMed
Right arrow Alert me to new issues of the journal
Right arrow Download to citation manager
Right arrow reprints & permissions
Citing Articles
Right arrow Citing Articles via HighWire
Right arrow Citing Articles via Google Scholar
Google Scholar
Right arrow Articles by Marquet, P. Y.
Right arrow Articles by Pau, B.
Right arrow Search for Related Content
PubMed
Right arrow PubMed Citation
Right arrow Articles by Marquet, P. Y.
Right arrow Articles by Pau, B.

Clinical Chemistry, Vol 42, 258-262, Copyright © 1996 by American Association for Clinical Chemistry

Highly sensitive immunoradiometric assay for serum thyroglobulin with minimal interference from autoantibodies

PY Marquet, A Daver, R Sapin, B Bridgi, JP Muratet, DJ Hartmann, F Paolucci and B Pau
ERIA Diagnostics Pasteur, Marnes la Coquette, France.

Five monoclonal antibodies (MAbs) directed against antigenic domains on thyroglobulin (Tg) not recognized by most anti-Tg human autoantibodies (aAbs) have been used to develop an improved IRMA for serum Tg with a limit of detection of 0.2 micrograms/L. Samples are incubated for 3 h in tubes coated with four anti-Tg MAbs. After washing, the tubes are incubated with the tracer MAb for 20 h at room temperature. Dilution and reproducibility tests demonstrated assay reliability. Tests performed on samples with (n = 361) or without (n = 283) aAbs showed that the TG IRMA Pasteur is largely independent of the marked interference generally caused by aAbs. These results were confirmed with an extended population of 2759 samples. For a cutoff of 1 micrograms/L, sensitivity and specificity were 0.97 and 1, respectively, in a follow-up of differentiated thyroid carcinoma in patients treated by total thyroidectomy.


The following articles in journals at HighWire Press have cited this article:


Home page
Clin. Chem.Home page
B. Lumbreras-Lacarra, J. M. Ramos-Rincon, and I. Hernandez-Aguado
Methodology in Diagnostic Laboratory Test Research in Clinical Chemistry and Clinical Chemistry and Laboratory Medicine
Clin. Chem., March 1, 2004; 50(3): 530 - 536.
[Abstract] [Full Text] [PDF]


Home page
Clin. Chem.Home page
N. G. Morgenthaler, J. Froehlich, J. Rendl, M. Willnich, C. Alonso, A. Bergmann, and C. Reiners
Technical Evaluation of a New Immunoradiometric and a New Immunoluminometric Assay for Thyroglobulin
Clin. Chem., July 1, 2002; 48(7): 1077 - 1083.
[Abstract] [Full Text] [PDF]


Home page
Clin. Chem.Home page
C. Calzolari, P.-Y. Marquet, B. Pau, C. A. Spencer, and M. Takeuchi
Thyroglobulin IRMA Pasteur Immunoassay: Sensitivity of the Assay and Interference from Thyroglobulin Autoantibodies • The authors of the above-mentioned article and editorial reply:
Clin. Chem., February 1, 1997; 43(2): 413 - 415.
[Full Text]




HOME HELP FEEDBACK SUBSCRIPTIONS ARCHIVE SEARCH TABLE OF CONTENTS
Copyright © 1996 by the American Association for Clinical Chemistry.