Clinical Chemistry
HOME HELP FEEDBACK SUBSCRIPTIONS ARCHIVE SEARCH TABLE OF CONTENTS
 QUICK SEARCH:   [advanced]


     


Clinical Chemistry 42: 545-550, 1996;
This Article
Right arrow Full Text (PDF)
Right arrow Alert me when this article is cited
Right arrow Alert me if a correction is posted
Right arrow Citation Map
Services
Right arrow Email this article to a friend
Right arrow Similar articles in this journal
Right arrow Similar articles in PubMed
Right arrow Alert me to new issues of the journal
Right arrow Download to citation manager
Right arrow reprints & permissions
Citing Articles
Right arrow Citing Articles via HighWire
Right arrow Citing Articles via Google Scholar
Google Scholar
Right arrow Articles by Espana, F.
Right arrow Articles by Heeb, M. J.
Right arrow Search for Related Content
PubMed
Right arrow PubMed Citation
Right arrow Articles by Espana, F.
Right arrow Articles by Heeb, M. J.

Clinical Chemistry, Vol 42, 545-550, Copyright © 1996 by American Association for Clinical Chemistry

Quantitative immunoassay for complexes of prostate-specific antigen with alpha2-macroglobulin

F Espana, J Sanchez-Cuenca, A Estelles, J Gilabert, JH Griffin and MJ Heeb
Research Center, La Fe Univesity Hospital, Valencia, Spain.

We have developed two ELISAs for quantifying complexes of prostate- specific antigen (PSA) with alpha2-macroglobulin (alpha2M), using partially purified PSA:alpha2M complex as the calibrator. One ELISA was designed to evaluate )SA:alpha2M complex in fluids containing a huge excess of PSA over the amount of complex (semen-derived fluids), the other for use in fluids containing an excess of alpha2M over PSA (blood plasma). The range of the assays was 2-1000 micrograms/L for PSA complexed to alpha2M; the detection limit was 3 micrograms/: Intra- and interassay CVs were 7-13% and 11-17%, respectively, at complexed PSA concentrations of 6-500 micrograms/L. Seminal fluid from healthy men (n = 60) contained 5.2 +/- 2.6 micrograms/L PSA complexed with alpha2M. Prostatic and seminal vesicle fluids contained 6.5 +/- 2.9 ad 0.3 +/- 0.2 mg/L PSA complexed to alpha2M, respectively. When purified PSA was incubated with citrated plasma, between 45% and 65% of the added PSA was recovered as free PSA, whereas approximately 25% formed complexes with alpha2M, 10% complexed with alpha1-antichymotrypsin, and only 0.1- 6% was complexed with protein C inhibitor. Of 30 patients with prostate disease, 20 showed detectable plasma PSA:alpha2M complexes; however, the potential diagnostic significance of this complex requires further investigation.


The following articles in journals at HighWire Press have cited this article:


Home page
Clin. Chem.Home page
M. Martinez, F. Espana, M. Royo, J. M. Alapont, S. Navarro, A. Estelles, J. Aznar, C. D. Vera, and J. F. Jimenez-Cruz
The Proportion of Prostate-specific Antigen (PSA) Complexed to {alpha}1-Antichymotrypsin Improves the Discrimination between Prostate Cancer and Benign Prostatic Hyperplasia in Men with a Total PSA of 10 to 30 {micro}g/L
Clin. Chem., August 1, 2002; 48(8): 1251 - 1256.
[Abstract] [Full Text] [PDF]


Home page
Cancer Epidemiol. Biomarkers Prev.Home page
C. Stephan, K. Jung, M. Lein, P. Sinha, D. Schnorr, and S. A. Loening
Molecular Forms of Prostate-specific Antigen and Human Kallikrein 2 as Promising Tools for Early Diagnosis of Prostate Cancer
Cancer Epidemiol. Biomarkers Prev., November 1, 2000; 9(11): 1133 - 1147.
[Abstract] [Full Text]


Home page
Clin. Chem.Home page
D. W. Chan and L. J. Sokoll
Prostate-specific Antigen: Advances and Challenges
Clin. Chem., June 1, 1999; 45(6): 755 - 756.
[Full Text] [PDF]


Home page
Clin. Chem.Home page
S. Michel, G. Deleage, J.-P. Charrier, J. Passagot, N. Battail-Poirot, G. Sibai, M. Jolivet, and C. Jolivet-Reynaud
Anti-Free Prostate-specific Antigen Monoclonal Antibody Epitopes Defined by Mimotopes and Molecular Modeling
Clin. Chem., May 1, 1999; 45(5): 638 - 650.
[Abstract] [Full Text] [PDF]


Home page
Clin. Chem.Home page
W.-M. Zhang, P. Finne, J. Leinonen, S. Vesalainen, S. Nordling, S. Rannikko, and U.-H. Stenman
Characterization and immunological determination of the complex between prostate-specific antigen and {alpha}2-macroglobulin
Clin. Chem., December 1, 1998; 44(12): 2471 - 2479.
[Abstract] [Full Text] [PDF]


Home page
Clin. Chem.Home page
C. Y. Cheung, D. J. Green, G. J. Litt, and J. A. Laugharn Jr.
High-pressure-mediated dissociation of immune complexes demonstrated in model systems
Clin. Chem., February 1, 1998; 44(2): 299 - 303.
[Abstract] [Full Text] [PDF]


Home page
Clin. Chem.Home page
Y. Qian, J. A. Sensibar, D. J. Zelner, A. J. Schaeffer, J. A. Finlay, H. G. Rittenhouse, and C. Lee
Two-dimensional gel electrophoresis detects prostate-specific antigen–{alpha}1-antichymotrypsin complex in serum but not in prostatic fluid
Clin. Chem., February 1, 1997; 43(2): 352 - 359.
[Abstract] [Full Text] [PDF]




HOME HELP FEEDBACK SUBSCRIPTIONS ARCHIVE SEARCH TABLE OF CONTENTS
Copyright © 1996 by the American Association for Clinical Chemistry.