Clinical Chemistry AACC Online Job Center
HOME HELP FEEDBACK SUBSCRIPTIONS ARCHIVE SEARCH TABLE OF CONTENTS
 QUICK SEARCH:   [advanced]


     


Clinical Chemistry 42: 551-557, 1996;
This Article
Right arrow Full Text (PDF)
Right arrow Submit an electronic Letter to
the Editor about this paper
Right arrow Alert me when this article is cited
Right arrow Alert me when eLetters are posted
Right arrow Alert me if a correction is posted
Right arrow Citation Map
Services
Right arrow Email this article to a friend
Right arrow Similar articles in this journal
Right arrow Similar articles in PubMed
Right arrow Alert me to new issues of the journal
Right arrow Download to citation manager
Right arrow reprints & permissions
Citing Articles
Right arrow Citing Articles via HighWire
Right arrow Citing Articles via Google Scholar
Google Scholar
Right arrow Articles by Schellenberg, F.
Right arrow Articles by Weill, J.
Right arrow Search for Related Content
PubMed
Right arrow PubMed Citation
Right arrow Articles by Schellenberg, F.
Right arrow Articles by Weill, J.

Clinical Chemistry, Vol 42, 551-557, Copyright © 1996 by American Association for Clinical Chemistry

Nephelometric determination of carbohydrate deficient transferrin

F Schellenberg, M Martin, E Caces, JY Benard and J Weill
Laboratory of Biochemistry, CHU Trousseau, Tours, France.

We describe a technique for measuring carbohydrate-deficient transferrin (CDT) in serum. Serum transferrin fractions are separated by anion-exchange chromatography on microcolumns. Sialic acid-deficient transferrin fractions are collected in the eluate, and transferrin is then quantified by a rate-nephelometric technique. Imprecision (CV) was 4-5% within-run and 7-9% between runs (n = 15). Comparison with an isoelectric focusing-immunofixation method for transferrin index (x) yielded y = 761x + 7, Sy/x = 39 mg/L. Assay of sera from 90 abstainers or moderate consumers of alcohol showed that 81 (90%) had CDT concentrations between 30 and 70 mg/L. Among 74 alcoholics admitted to an alcohol treatment center, 54 (73%) had CDT > 70 mg/L, i.e., the diagnostic sensitivity was 73% at a specificity of 90% (area under receiver-operator characteristic curve = 0.891).


The following articles in journals at HighWire Press have cited this article:


Home page
Alcohol AlcoholHome page
F. SCHELLENBERG, R. SCHWAN, L. MENNETREY, M.-N. LOISEAUX, J. C. PAGES, and M. REYNAUD
DOSE-EFFECT RELATION BETWEEN DAILY ETHANOL INTAKE IN THE RANGE 0-70 GRAMS AND %CDT VALUE: VALIDATION OF A CUT-OFF VALUE
Alcohol Alcohol., November 1, 2005; 40(6): 531 - 534.
[Abstract] [Full Text] [PDF]


Home page
Clin. Chem.Home page
B. Lumbreras-Lacarra, J. M. Ramos-Rincon, and I. Hernandez-Aguado
Methodology in Diagnostic Laboratory Test Research in Clinical Chemistry and Clinical Chemistry and Laboratory Medicine
Clin. Chem., March 1, 2004; 50(3): 530 - 536.
[Abstract] [Full Text] [PDF]


Home page
Am. J. PsychiatryHome page
M. Reynaud, R. Schwan, M.-N. Loiseaux-Meunier, E. Albuisson, and P. Deteix
Patients Admitted to Emergency Services for Drunkenness: Moderate Alcohol Users or Harmful Drinkers?
Am J Psychiatry, January 1, 2001; 158(1): 96 - 99.
[Abstract] [Full Text]


Home page
Clin. Chem.Home page
T. Arndt, R. Hackler, T. O. Kleine, and A. M. Gressner
Validation by isoelectric focusing of the anion-exchange isotransferrin fractionation step involved in determination of carbohydrate-deficient transferrin by the CDTect assay
Clin. Chem., January 1, 1998; 44(1): 27 - 34.
[Abstract] [Full Text] [PDF]


Home page
Clin. Chem.Home page
F. Renner and R.-D. Kanitz
Quantification of carbohydrate-deficient transferrin by ion-exchange chromatography with an enzymatically prepared calibrator
Clin. Chem., March 1, 1997; 43(3): 485 - 490.
[Abstract] [Full Text] [PDF]




HOME HELP FEEDBACK SUBSCRIPTIONS ARCHIVE SEARCH TABLE OF CONTENTS
Copyright © 1996 by the American Association for Clinical Chemistry.