|
|
||||||||
Clinical Chemistry, Vol 42, 551-557, Copyright © 1996 by American Association for Clinical Chemistry
F Schellenberg, M Martin, E Caces, JY Benard and J Weill
Laboratory of Biochemistry, CHU Trousseau, Tours, France.
We describe a technique for measuring carbohydrate-deficient transferrin (CDT) in serum. Serum transferrin fractions are separated by anion-exchange chromatography on microcolumns. Sialic acid-deficient transferrin fractions are collected in the eluate, and transferrin is then quantified by a rate-nephelometric technique. Imprecision (CV) was 4-5% within-run and 7-9% between runs (n = 15). Comparison with an isoelectric focusing-immunofixation method for transferrin index (x) yielded y = 761x + 7, Sy/x = 39 mg/L. Assay of sera from 90 abstainers or moderate consumers of alcohol showed that 81 (90%) had CDT concentrations between 30 and 70 mg/L. Among 74 alcoholics admitted to an alcohol treatment center, 54 (73%) had CDT > 70 mg/L, i.e., the diagnostic sensitivity was 73% at a specificity of 90% (area under receiver-operator characteristic curve = 0.891).
The following articles in journals at HighWire Press have cited this article:
![]() |
F. SCHELLENBERG, R. SCHWAN, L. MENNETREY, M.-N. LOISEAUX, J. C. PAGES, and M. REYNAUD DOSE-EFFECT RELATION BETWEEN DAILY ETHANOL INTAKE IN THE RANGE 0-70 GRAMS AND %CDT VALUE: VALIDATION OF A CUT-OFF VALUE Alcohol Alcohol., November 1, 2005; 40(6): 531 - 534. [Abstract] [Full Text] [PDF] |
||||
![]() |
B. Lumbreras-Lacarra, J. M. Ramos-Rincon, and I. Hernandez-Aguado Methodology in Diagnostic Laboratory Test Research in Clinical Chemistry and Clinical Chemistry and Laboratory Medicine Clin. Chem., March 1, 2004; 50(3): 530 - 536. [Abstract] [Full Text] [PDF] |
||||
![]() |
M. Reynaud, R. Schwan, M.-N. Loiseaux-Meunier, E. Albuisson, and P. Deteix Patients Admitted to Emergency Services for Drunkenness: Moderate Alcohol Users or Harmful Drinkers? Am J Psychiatry, January 1, 2001; 158(1): 96 - 99. [Abstract] [Full Text] |
||||
![]() |
T. Arndt, R. Hackler, T. O. Kleine, and A. M. Gressner Validation by isoelectric focusing of the anion-exchange isotransferrin fractionation step involved in determination of carbohydrate-deficient transferrin by the CDTect assay Clin. Chem., January 1, 1998; 44(1): 27 - 34. [Abstract] [Full Text] [PDF] |
||||
![]() |
F. Renner and R.-D. Kanitz Quantification of carbohydrate-deficient transferrin by ion-exchange chromatography with an enzymatically prepared calibrator Clin. Chem., March 1, 1997; 43(3): 485 - 490. [Abstract] [Full Text] [PDF] |
||||
| HOME | HELP | FEEDBACK | SUBSCRIPTIONS | ARCHIVE | SEARCH | TABLE OF CONTENTS |