Clinical Chemistry AACC Online Job Center
HOME HELP FEEDBACK SUBSCRIPTIONS ARCHIVE SEARCH TABLE OF CONTENTS
 QUICK SEARCH:   [advanced]


     


Clinical Chemistry 42: 888-892, 1996;
This Article
Right arrow Full Text (PDF)
Right arrow Submit an electronic Letter to
the Editor about this paper
Right arrow Alert me when this article is cited
Right arrow Alert me when eLetters are posted
Right arrow Alert me if a correction is posted
Services
Right arrow Email this article to a friend
Right arrow Similar articles in this journal
Right arrow Similar articles in PubMed
Right arrow Alert me to new issues of the journal
Right arrow Download to citation manager
Right arrow reprints & permissions
Citing Articles
Right arrow Citing Articles via Google Scholar
Google Scholar
Right arrow Articles by Lott, J. A.
Right arrow Articles by Moeschberger, M. L.
Right arrow Search for Related Content
PubMed
Right arrow PubMed Citation
Right arrow Articles by Lott, J. A.
Right arrow Articles by Moeschberger, M. L.

Clinical Chemistry, Vol 42, 888-892, Copyright © 1996 by American Association for Clinical Chemistry

Use of medians and "average of normals" of patients' data for assessment of long-term analytical stability

JA Lott, DA Smith, LC Mitchell and ML Moeschberger
Department of Pathology, The Ohio State University, OSU Medical Center, Columbus, OH 43210, USA. jlott@magnus.acs.ohio-state.edu

Using results from patients, we studied several methods for long-term (years) monitoring of the analytical stability of various chemistry tests. For each test, we obtained on a bimonthly basis histograms of > or = 200 to approximately 2000 data points and determined the median, mean, and mean of those data points in the reference range ("average of normal" or AON). Examining approximately 4 years' data, we found that the medians and AON are extremely stable for most tests, and that all observed shifts in the medians or in the AON could be explained by expected or unexpected changes in the laboratory. The means and peak values of the Erlang (gamma) distribution were less useful, owing to shifts caused by extreme outliers, especially for enzymes in serum. We assumed that the underlying patient population and testing patterns were stable. We recommend the use of medians or the AON of patients' data under defined conditions for monitoring the long-term analytical stability of certain tests involving serum or whole blood.





HOME HELP FEEDBACK SUBSCRIPTIONS ARCHIVE SEARCH TABLE OF CONTENTS
Copyright © 1996 by the American Association for Clinical Chemistry.