Clinical Chemistry AACC Online Job Center
HOME HELP FEEDBACK SUBSCRIPTIONS ARCHIVE SEARCH TABLE OF CONTENTS
 QUICK SEARCH:   [advanced]


     


Clinical Chemistry 42: 1445-1449, 1996;
This Article
Right arrow Full Text (PDF)
Right arrow Submit an electronic Letter to
the Editor about this paper
Right arrow Alert me when this article is cited
Right arrow Alert me when eLetters are posted
Right arrow Alert me if a correction is posted
Right arrow Citation Map
Services
Right arrow Email this article to a friend
Right arrow Similar articles in this journal
Right arrow Similar articles in PubMed
Right arrow Alert me to new issues of the journal
Right arrow Download to citation manager
Right arrow reprints & permissions
Citing Articles
Right arrow Citing Articles via HighWire
Right arrow Citing Articles via Google Scholar
Google Scholar
Right arrow Articles by Wheeler, M. J.
Right arrow Articles by Croos, P.
Right arrow Search for Related Content
PubMed
Right arrow PubMed Citation
Right arrow Articles by Wheeler, M. J.
Right arrow Articles by Croos, P.

Clinical Chemistry, Vol 42, 1445-1449, Copyright © 1996 by American Association for Clinical Chemistry

Ciba Corning ACS:180 testosterone assay evaluated

MJ Wheeler, A D'Souza, J Matadeen and P Croos
Department of Chemical Pathology, St. Thomas' Hospital, London, UK.

A fully automated direct assay of testosterone has been developed for the Ciba Corning ACS:180 immunoassay system. We have evaluated this method and compared specimen results with those from the Diagnostic Products Corp. (DPC) and Medgenix direct assays and an in-house extraction assay. Accuracy of the method was assessed by measuring GC- MS-targeted serum pools. Within-assay im- precision was <6% and between- assay imprecision <9% over the concentration range examined. High concentrations of lipid caused an increase in the measured testosterone but other potential interferents were without effect. Recovery was quantitative but was affected by sex-hormone-binding globulin. The method was positively biased with respect to the DPC and Medgenix assays but negatively biased with the extraction assay. Measurement of the GC-MS-targeted serum pools showed the assay to overestimate recovery by approximately 13%. The ACS:180 assay is particularly attractive as a routine assay because it is fully automated, obtains the first result in only 15 min, and shows good assay performance.


The following articles in journals at HighWire Press have cited this article:


Home page
Clin. Chem.Home page
M. M. Kushnir, A. L. Rockwood, W. L. Roberts, E. G. Pattison, A. M. Bunker, R. L. Fitzgerald, and A. W. Meikle
Performance Characteristics of a Novel Tandem Mass Spectrometry Assay For Serum Testosterone
Clin. Chem., January 1, 2006; 52(1): 120 - 128.
[Abstract] [Full Text] [PDF]


Home page
Clin. Chem.Home page
J. Taieb, B. Mathian, F. Millot, M.-C. Patricot, E. Mathieu, N. Queyrel, I. Lacroix, C. Somma-Delpero, and P. Boudou
Testosterone Measured by 10 Immunoassays and by Isotope-Dilution Gas Chromatography-Mass Spectrometry in Sera from 116 Men, Women, and Children
Clin. Chem., August 1, 2003; 49(8): 1381 - 1395.
[Abstract] [Full Text] [PDF]


Home page
J. Clin. Endocrinol. Metab.Home page
C. Regnier, A. Bennet, D. Malet, T. Guez, M. Plantavid, P. Rochaix, X. Monrozies, J.-P. Louvet, and P. Caron
Intraoperative Testosterone Assay for Virilizing Ovarian Tumor Topographic Assessment: Report of a Leydig Cell Tumor of the Ovary in a Premenopausal Woman with an Adrenal Incidentaloma
J. Clin. Endocrinol. Metab., July 1, 2002; 87(7): 3074 - 3077.
[Abstract] [Full Text] [PDF]


Home page
Cancer Epidemiol. Biomarkers Prev.Home page
S. Rinaldi, H. Dechaud, C. Biessy, V. Morin-Raverot, P. Toniolo, A. Zeleniuch-Jacquotte, A. Akhmedkhanov, R. E. Shore, G. Secreto, A. Ciampi, et al.
Reliability and Validity of Commercially Available, Direct Radioimmunoassays for Measurement of Blood Androgens and Estrogens in Postmenopausal Women
Cancer Epidemiol. Biomarkers Prev., July 1, 2001; 10(7): 757 - 765.
[Abstract] [Full Text] [PDF]


Home page
Biol. Reprod.Home page
J. D. Wilson, F. W. George, G. Shaw, and M. B. Renfree
Virilization of the Male Pouch Young of the Tammar Wallaby Does Not Appear to be Mediated by Plasma Testosterone or Dihydrotestosterone
Biol Reprod, August 1, 1999; 61(2): 471 - 475.
[Abstract] [Full Text]


Home page
Clin. Chem.Home page
M. Sanchez-Carbayo, M. Mauri, R. Alfayate, C. Miralles, and F. Soria
Elecsys Testosterone Assay Evaluated
Clin. Chem., August 1, 1998; 44(8): 1744 - 1746.
[Full Text] [PDF]


Home page
Clin. Chem.Home page
P. Luppa, C. Bruckner, I. Schwab, S. Hauck, S. Schmidmayr, C. Birkmayer, B. Paulus, and H. Hauptmann
7{alpha}-Biotinylated testosterone derivatives as tracers for a competitive chemiluminescence immunoassay of testosterone in serum
Clin. Chem., December 1, 1997; 43(12): 2345 - 2352.
[Abstract] [Full Text] [PDF]


Home page
Clin. Chem.Home page
D. J. O'Kane, T. A. Ebert, B. J. Hallaway, S. G. Roberts, A. K. M. J. Bhuiyan, and K. S. Tenner
A laboratorian's perspective on evaluation and implementation of new laboratory tests
Clin. Chem., September 1, 1997; 43(9): 1771 - 1780.
[Abstract] [Full Text] [PDF]


Home page
Clin. Chem.Home page
F. H. Wians Jr., J. Stuart, R. L. Fitzgerald, and D. A. Herold
Ciba Corning ACS:180 Direct Total Testosterone Assay Can Be Used on Female Sera • The authors of the report referred to reply:
Clin. Chem., August 1, 1997; 43(8): 1466 - 1468.
[Full Text]


Home page
Clin. Chem.Home page
Y.-S. Leung, K. Dees, R. Cyr, I. Schloegel, and P. C. Kao
Falsely Increased Serum Estradiol Results Reported in Direct Estradiol Assays
Clin. Chem., July 1, 1997; 43(7): 1250 - 1251.
[Full Text]




HOME HELP FEEDBACK SUBSCRIPTIONS ARCHIVE SEARCH TABLE OF CONTENTS
Copyright © 1996 by the American Association for Clinical Chemistry.