|
|
||||||||
Clinical Chemistry, Vol 42, 1445-1449, Copyright © 1996 by American Association for Clinical Chemistry
MJ Wheeler, A D'Souza, J Matadeen and P Croos
Department of Chemical Pathology, St. Thomas' Hospital, London, UK.
A fully automated direct assay of testosterone has been developed for the Ciba Corning ACS:180 immunoassay system. We have evaluated this method and compared specimen results with those from the Diagnostic Products Corp. (DPC) and Medgenix direct assays and an in-house extraction assay. Accuracy of the method was assessed by measuring GC- MS-targeted serum pools. Within-assay im- precision was <6% and between- assay imprecision <9% over the concentration range examined. High concentrations of lipid caused an increase in the measured testosterone but other potential interferents were without effect. Recovery was quantitative but was affected by sex-hormone-binding globulin. The method was positively biased with respect to the DPC and Medgenix assays but negatively biased with the extraction assay. Measurement of the GC-MS-targeted serum pools showed the assay to overestimate recovery by approximately 13%. The ACS:180 assay is particularly attractive as a routine assay because it is fully automated, obtains the first result in only 15 min, and shows good assay performance.
The following articles in journals at HighWire Press have cited this article:
![]() |
M. M. Kushnir, A. L. Rockwood, W. L. Roberts, E. G. Pattison, A. M. Bunker, R. L. Fitzgerald, and A. W. Meikle Performance Characteristics of a Novel Tandem Mass Spectrometry Assay For Serum Testosterone Clin. Chem., January 1, 2006; 52(1): 120 - 128. [Abstract] [Full Text] [PDF] |
||||
![]() |
J. Taieb, B. Mathian, F. Millot, M.-C. Patricot, E. Mathieu, N. Queyrel, I. Lacroix, C. Somma-Delpero, and P. Boudou Testosterone Measured by 10 Immunoassays and by Isotope-Dilution Gas Chromatography-Mass Spectrometry in Sera from 116 Men, Women, and Children Clin. Chem., August 1, 2003; 49(8): 1381 - 1395. [Abstract] [Full Text] [PDF] |
||||
![]() |
C. Regnier, A. Bennet, D. Malet, T. Guez, M. Plantavid, P. Rochaix, X. Monrozies, J.-P. Louvet, and P. Caron Intraoperative Testosterone Assay for Virilizing Ovarian Tumor Topographic Assessment: Report of a Leydig Cell Tumor of the Ovary in a Premenopausal Woman with an Adrenal Incidentaloma J. Clin. Endocrinol. Metab., July 1, 2002; 87(7): 3074 - 3077. [Abstract] [Full Text] [PDF] |
||||
![]() |
S. Rinaldi, H. Dechaud, C. Biessy, V. Morin-Raverot, P. Toniolo, A. Zeleniuch-Jacquotte, A. Akhmedkhanov, R. E. Shore, G. Secreto, A. Ciampi, et al. Reliability and Validity of Commercially Available, Direct Radioimmunoassays for Measurement of Blood Androgens and Estrogens in Postmenopausal Women Cancer Epidemiol. Biomarkers Prev., July 1, 2001; 10(7): 757 - 765. [Abstract] [Full Text] [PDF] |
||||
![]() |
J. D. Wilson, F. W. George, G. Shaw, and M. B. Renfree Virilization of the Male Pouch Young of the Tammar Wallaby Does Not Appear to be Mediated by Plasma Testosterone or Dihydrotestosterone Biol Reprod, August 1, 1999; 61(2): 471 - 475. [Abstract] [Full Text] |
||||
![]() |
M. Sanchez-Carbayo, M. Mauri, R. Alfayate, C. Miralles, and F. Soria Elecsys Testosterone Assay Evaluated Clin. Chem., August 1, 1998; 44(8): 1744 - 1746. [Full Text] [PDF] |
||||
![]() |
P. Luppa, C. Bruckner, I. Schwab, S. Hauck, S. Schmidmayr, C. Birkmayer, B. Paulus, and H. Hauptmann 7{alpha}-Biotinylated testosterone derivatives as tracers for a competitive chemiluminescence immunoassay of testosterone in serum Clin. Chem., December 1, 1997; 43(12): 2345 - 2352. [Abstract] [Full Text] [PDF] |
||||
![]() |
D. J. O'Kane, T. A. Ebert, B. J. Hallaway, S. G. Roberts, A. K. M. J. Bhuiyan, and K. S. Tenner A laboratorian's perspective on evaluation and implementation of new laboratory tests Clin. Chem., September 1, 1997; 43(9): 1771 - 1780. [Abstract] [Full Text] [PDF] |
||||
![]() |
F. H. Wians Jr., J. Stuart, R. L. Fitzgerald, and D. A. Herold Ciba Corning ACS:180 Direct Total Testosterone Assay Can Be Used on Female Sera • The authors of the report referred to reply: Clin. Chem., August 1, 1997; 43(8): 1466 - 1468. [Full Text] |
||||
![]() |
Y.-S. Leung, K. Dees, R. Cyr, I. Schloegel, and P. C. Kao Falsely Increased Serum Estradiol Results Reported in Direct Estradiol Assays Clin. Chem., July 1, 1997; 43(7): 1250 - 1251. [Full Text] |
||||
| HOME | HELP | FEEDBACK | SUBSCRIPTIONS | ARCHIVE | SEARCH | TABLE OF CONTENTS |