|
|
||||||||
Point/Counterpoint |
Department of Molecular Endocrinology, University College London Medical School, University College London, London W1 N 8AA, UK.
a Author for correspondence. Fax +44 171 580 2737; e-mail r.ekins{at}ucl.ac.uk
Abstract
The term "sensitivity" (as applied to an analytical method's performance) has again become a subject of controversy. Certain authorities (e.g., IUPAC) define a system's sensitivity as the response curve slope (or response/dose), others (e.g., IFCC) in terms of the detection limit. Many investigators have failed to perceive the contradiction between these concepts, wrongly assuming that maximizing "sensitivity" in the first sense maximizes it in the second (i.e., that they are inversely related). The existence of different meanings for this term (when used in the present context) is a source of confusion that has, among other things, led to erroneous ideas relating to immunoassay design. Such confusion should be terminated by adoption of one or the other of the definitions. However, the definitions are not of equal merit. We advance arguments against retention of the "slope" definition, which conflicts with the word's common meaning and is meaningless as an indicator of the performance of a measuring system.
The following articles in journals at HighWire Press have cited this article:
![]() |
K. Skogstrand, P. Thorsen, B. Norgaard-Pedersen, D. E. Schendel, L. C. Sorensen, and D. M. Hougaard Simultaneous Measurement of 25 Inflammatory Markers and Neurotrophins in Neonatal Dried Blood Spots by Immunoassay with xMAP Technology Clin. Chem., October 1, 2005; 51(10): 1854 - 1866. [Abstract] [Full Text] [PDF] |
||||
![]() |
L. Kokko, N. Johansson, T. Lovgren, and T. Soukka Enzyme Inhibitor Screening Using a Homogeneous Proximity-Based Immunoassay for Estradiol J Biomol Screen, June 1, 2005; 10(4): 348 - 354. [Abstract] [PDF] |
||||
![]() |
A. Halperin, A. Buhot, and E.B. Zhulina Sensitivity, Specificity, and the Hybridization Isotherms of DNA Chips Biophys. J., February 1, 2004; 86(2): 718 - 730. [Abstract] [Full Text] [PDF] |
||||
![]() |
R. P. Ekins Ligand assays: from electrophoresis to miniaturized microarrays Clin. Chem., September 1, 1998; 44(9): 2015 - 2030. [Abstract] [Full Text] [PDF] |
||||
![]() |
H. L. Pardue Dr. Pardue responds: Clin. Chem., August 1, 1998; 44(8): 1776 - 1778. [Full Text] |
||||
![]() |
R. Ekins and P. Edwards On the Meaning of ""Sensitivity"": A Rejoinder Clin. Chem., August 1, 1998; 44(8): 1773 - 1776. [Full Text] |
||||
![]() |
H. L. Pardue Counterpoint The inseparable triad: analytical sensitivity, measurement uncertainty, and quantitative resolution Clin. Chem., October 1, 1997; 43(10): 1831 - 1837. [Abstract] [Full Text] |
||||
| HOME | HELP | FEEDBACK | SUBSCRIPTIONS | ARCHIVE | SEARCH | TABLE OF CONTENTS |