Clinical Chemistry Link to Randox Laboratories Web Site
HOME HELP FEEDBACK SUBSCRIPTIONS ARCHIVE SEARCH TABLE OF CONTENTS
 QUICK SEARCH:   [advanced]


     


Clinical Chemistry 43: 2039-2046, 1997;
This Article
Right arrow Full Text
Right arrow Full Text (PDF)
Right arrow Submit an electronic Letter to
the Editor about this paper
Right arrow Alert me when this article is cited
Right arrow Alert me when eLetters are posted
Right arrow Alert me if a correction is posted
Right arrow Citation Map
Services
Right arrow Email this article to a friend
Right arrow Similar articles in this journal
Right arrow Similar articles in ISI Web of Science
Right arrow Similar articles in PubMed
Right arrow Alert me to new issues of the journal
Right arrow Download to citation manager
Right arrow reprints & permissions
Citing Articles
Right arrow Citing Articles via HighWire
Right arrow Citing Articles via ISI Web of Science (45)
Right arrow Citing Articles via Google Scholar
Google Scholar
Right arrow Articles by Petersen, P. H.
Right arrow Articles by Kjeldsen, J.
Right arrow Search for Related Content
PubMed
Right arrow PubMed Citation
Right arrow Articles by Petersen, P. H.
Right arrow Articles by Kjeldsen, J.
Related Collections
Right arrow Laboratory Management
(Clinical Chemistry. 1997;43:2039-2046.)
© 1997 American Association for Clinical Chemistry, Inc.


Articles

Graphical interpretation of analytical data from comparison of a field method with a Reference Method by use of difference plots

Per Hyltoft Petersena, Dietmar Stöckl, Ole Blaabjerg, Bent Pedersen, Erling Birkemose, Linda Thienpont, Jens Flensted Lassen1 and Jens Kjeldsen

1 Department of Clinical Chemistry, Vejle Sygehus, DK-7100 Vejle, Denmark.
a Author for correspondence. Fax + 45 65 41 19 11; e-mail phy{at}imbmed ou.dk.

Various viewpoints have been offered regarding the appropriate use of scatter plots or difference plots (bias plots or residual plots) in comparing analytical methods. In many of these discussions it seems the basic concepts of identity (within inherent imprecision) and acceptability based on analytical goals (analytical quality specifications) have been forgotten. With the increasing number of Reference Methods in laboratory medicine, these basic concepts are becoming more important in validation of field methods. Here we describe a simple and effective graphical test of these hypotheses (identity and acceptability) by use of difference plots. These plots display the underlying hypothesis before the measured differences are plotted and allow interpretation of the results according to specific criteria. We further describe simple but effective interpretations of the data, when the hypothesis is not fulfilled, by using two data sets drawn from comparisons of field methods for S-creatinine with a Reference Method for this analyte. The difference plot is a graphical tool with related simple statistics for comparison of a field method with a Reference Method, focusing on (a) identity within the inherent analytical imprecision or (b) acceptability within analytical quality specifications. Calculation of the standard deviation of the differences is an indispensable tool for evaluation of aberrant-sample bias (matrix effects).




The following articles in journals at HighWire Press have cited this article:


Home page
J. Clin. Pathol.Home page
W S Waring, L E Evans, and C T Kirkpatrick
Glycolysis inhibitors negatively bias blood glucose measurements: potential impact on the reported prevalence of diabetes mellitus
J. Clin. Pathol., July 1, 2007; 60(7): 820 - 923.
[Abstract] [Full Text] [PDF]


Home page
Clin. Chem.Home page
A. Olsson, H. Vanderstichele, N. Andreasen, G. De Meyer, A. Wallin, B. Holmberg, L. Rosengren, E. Vanmechelen, and K. Blennow
Simultaneous Measurement of {beta}-Amyloid(1-42), Total Tau, and Phosphorylated Tau (Thr181) in Cerebrospinal Fluid by the xMAP Technology
Clin. Chem., February 1, 2005; 51(2): 336 - 345.
[Abstract] [Full Text] [PDF]


Home page
Clin. Chem.Home page
J. S. Krouwer
Setting Performance Goals and Evaluating Total Analytical Error for Diagnostic Assays
Clin. Chem., June 1, 2002; 48(6): 919 - 927.
[Abstract] [Full Text] [PDF]


Home page
Clin. Chem.Home page
K. Dewitte, C. Fierens, D. Stockl, and L. M. Thienpont
Application of the Bland-Altman Plot for Interpretation of Method-Comparison Studies: A Critical Investigation of Its Practice
Clin. Chem., May 1, 2002; 48(5): 799 - 801.
[Full Text] [PDF]


Home page
Clin. Chem.Home page
D. G. Altman and J. M. Bland
Commentary on Quantifying Agreement between Two Methods of Measurement
Clin. Chem., May 1, 2002; 48(5): 801 - 802.
[Full Text] [PDF]


Home page
Clin. Chem.Home page
T. Ohashi, M. Yamaki, C. S. Pandav, M. G. Karmarkar, and M. Irie
Simple Microplate Method for Determination of Urinary Iodine
Clin. Chem., April 1, 2000; 46(4): 529 - 536.
[Abstract] [Full Text] [PDF]


Home page
Clin. Chem.Home page
C. H. Flowers and J. D. Cook
Dried Plasma Spot Measurements of Ferritin and Transferrin Receptor for Assessing Iron Status
Clin. Chem., October 1, 1999; 45(10): 1826 - 1832.
[Abstract] [Full Text] [PDF]


Home page
Clin. Chem.Home page
K. Linnet
Necessary Sample Size for Method Comparison Studies Based on Regression Analysis
Clin. Chem., June 1, 1999; 45(6): 882 - 894.
[Abstract] [Full Text] [PDF]


Home page
Clin. Chem.Home page
T. Q. Wei, V. P. Chu, A. R. Craig, J. E. Duffy, D. M. Obzansky, D. Kilgore, I. S. Masulli, C. M. Sanders, and J. C. Thompson
Automated Homogeneous Immunoassay for Gentamicin on the Dimension Clinical Chemistry System
Clin. Chem., March 1, 1999; 45(3): 388 - 393.
[Abstract] [Full Text] [PDF]


Home page
Clin. Chem.Home page
K. Linnet
Limitations of the Paired t-Test for Evaluation of Method Comparison Data
Clin. Chem., February 1, 1999; 45(2): 314 - 315.
[Full Text] [PDF]


Home page
Clin. Chem.Home page
I. Millard, E. Degrave, M. Philippe, and J.-L. Gala
Detection of intracellular antigens by flow cytometry: comparison of two chemical methods and microwave heating
Clin. Chem., November 1, 1998; 44(11): 2320 - 2330.
[Abstract] [Full Text] [PDF]


Home page
Clin. Chem.Home page
D. Stockl, K. Dewitte, and L. M. Thienpont
Validity of linear regression in method comparison studies: is it limited by the statistical model or the quality of the analytical input data?
Clin. Chem., November 1, 1998; 44(11): 2340 - 2346.
[Abstract] [Full Text] [PDF]


Home page
Clin. Chem.Home page
M. Andersen, P. H. Petersen, O. Blaabjerg, J. Hangaard, and C. Hagen
Evaluation of growth hormone assays using ratio plots
Clin. Chem., May 1, 1998; 44(5): 1032 - 1038.
[Abstract] [Full Text] [PDF]


Home page
Clin. Chem.Home page
L. M. Thienpont, J. E. Van Nuwenborg, and D. Stockl
Intrinsic and routine quality of serum total potassium measurement as investigated by split-sample measurement with an ion chromatography candidate reference method
Clin. Chem., April 1, 1998; 44(4): 849 - 857.
[Abstract] [Full Text] [PDF]




HOME HELP FEEDBACK SUBSCRIPTIONS ARCHIVE SEARCH TABLE OF CONTENTS
Copyright © 1997 by the American Association for Clinical Chemistry.