Clinical Chemistry
HOME HELP FEEDBACK SUBSCRIPTIONS ARCHIVE SEARCH TABLE OF CONTENTS
 QUICK SEARCH:   [advanced]


     


Clinical Chemistry 43: 2175-2182, 1997;
This Article
Right arrow Full Text
Right arrow Full Text (PDF)
Right arrow Alert me when this article is cited
Right arrow Alert me if a correction is posted
Right arrow Citation Map
Services
Right arrow Email this article to a friend
Right arrow Similar articles in this journal
Right arrow Similar articles in Web of Science
Right arrow Similar articles in PubMed
Right arrow Alert me to new issues of the journal
Right arrow Download to citation manager
Right arrow reprints & permissions
Citing Articles
Right arrow Citing Articles via HighWire
Right arrow Citing Articles via Web of Science (8)
Right arrow Citing Articles via Google Scholar
Google Scholar
Right arrow Articles by Kjeldsen, J.
Right arrow Articles by Brandslund, I.
Right arrow Search for Related Content
PubMed
Right arrow PubMed Citation
Right arrow Articles by Kjeldsen, J.
Right arrow Articles by Brandslund, I.
Related Collections
Right arrow Laboratory Management
Right arrow Evidence Based Laboratory Medicine and Test Utilization
Right arrow Drug Monitoring and Toxicology
Right arrow Hematology
(Clinical Chemistry. 1997;43:2175-2182.)
© 1997 American Association for Clinical Chemistry, Inc.


Articles

Biological variation of International Normalized Ratio for prothrombin times, and consequences in monitoring oral anticoagulant therapy: computer simulation of serial measurements with goal-setting for analytical quality

Jens Kjeldsen1, Jens Flensted Lassen2,4,a, Per Hyltoft Petersen3 and Ivan Brandslund4

Departments of
1 Medical Gastroenterology S and
2 Clinical Chemistry, Odense University Hospital, Denmark.
3 Department of Cardiology A, Århus Amtssygehus, 8000 Århus C, Denmark.

4 Department of Clinical Chemistry, Vejle County Hospital, Denmark.
a Address correspondence to this author, at the Århus Amtssygehus. Fax +45 89 49 76 19.

Oral anticoagulant therapy (OAT) has a well-established efficacy in prophylaxis and treatment of thromboembolic disorders. Because complications are related to intensity of OAT, optimal control of treatment is mandatory. In studies of OAT, as many as 30% of International Normalized Ratio (INR) measurements for prothrombin times fall outside the therapeutic interval. Preanalytical, analytical, and biological variation all contribute to this. Computer simulations of serial INR measurements were performed for various assumed in-treatment setpoints within the therapeutic interval INR 2.0–3.0 and for an "in-treatment within-subject variation" (CV) of 10.1%. Results are presented in difference plots with therapeutic intervals and critical differences. If the in-treatment setpoint is mid-interval (INR = 2.5), only 5% of simulated INR values fall outside the therapeutic interval. Setpoints deviating from the mid-interval and increases in the in-treatment within-subject variation considerably increase the number of observations outside the therapeutic interval and the critical differences. In conclusion, random variation, biological or analytical, and setpoints (targets) deviating from mid-interval explain a substantial number of the INR values outside therapeutic intervals observed in clinical studies. Analytical imprecision should be kept <5% and analytical bias <±0.2 INR.




The following articles in journals at HighWire Press have cited this article:


Home page
Clin. Chem.Home page
J. Horsti, H. Uppa, and J. A Vilpo
Poor Agreement among Prothrombin Time International Normalized Ratio Methods: Comparison of Seven Commercial Reagents
Clin. Chem., March 1, 2005; 51(3): 553 - 560.
[Abstract] [Full Text] [PDF]




HOME HELP FEEDBACK SUBSCRIPTIONS ARCHIVE SEARCH TABLE OF CONTENTS
Copyright © 1997 by the American Association for Clinical Chemistry.