|
|
||||||||
Articles |
1
Human Safety Department, 500 Miami Valley Laboratories, The Procter and Gamble Co., P.O. Box 538707, Cincinnati, OH 45253.
2
Division of Laboratory Medicine, Department of
Pathology, Washington University School of Medicine, St. Louis, MO
63110.
To identify a blood test that can differentiate cardiac from skeletal muscle injury in animals, we compared tissue reactivities for various species with the use of an immunoassay for human cardiac troponin I (cTnI). Tissue reactivity varied as a function of the homology of tissue troponin with human cTnI. Cardiac reactivity in large mammals was equivalent to cTnI, 9.8 ± 0.6 mg/g, and was 2-fold, 10-fold, and 100-fold greater than in small mammals, birds, and fish, respectively. Skeletal muscle reactivity was equivalent to cTnI, 5.1 ± 0.6 µg/g, in all species except fish, in which it was 50% lower. The ratio of reactivities of cardiac and skeletal muscle was: 1800 in large mammals, 1100 in small mammals, 230 in birds, and 43 in fish. We conclude that cTnI is a powerful candidate in mammals, a possible candidate in birds, but unlikely to be of use in fish as a sensitive and tissue-selective diagnostic test for cardiac injury.
The following articles in journals at HighWire Press have cited this article:
![]() |
V. Gunes, G. Atalan, M. Citil, and H. M. Erdogan Use of cardiac troponin kits for the qualitative determination of myocardial cell damage due to traumatic reticuloperitonitis in cattle Vet Rec., April 19, 2008; 162(16): 514 - 517. [Abstract] [Full Text] [PDF] |
||||
![]() |
S. Wang, J. Radhakrishnan, I. M. Ayoub, J. D. Kolarova, D. M. Taglieri, and R. J. Gazmuri Limiting sarcolemmal Na+ entry during resuscitation from ventricular fibrillation prevents excess mitochondrial Ca2+ accumulation and attenuates myocardial injury J Appl Physiol, July 1, 2007; 103(1): 55 - 65. [Abstract] [Full Text] [PDF] |
||||
![]() |
M. S. Willis, J. A. Snyder, R. H. Poppenga, and D. G. Grenache Bovine cardiac troponin T is not accurately quantified with a common human clinical immunoassay J Vet Diagn Invest, January 1, 2007; 19(1): 106 - 108. [Abstract] [Full Text] [PDF] |
||||
![]() |
D. B. Walker Serum Chemical Biomarkers of Cardiac Injury for Nonclinical Safety Testing Toxicol Pathol, January 1, 2006; 34(1): 94 - 104. [Abstract] [PDF] |
||||
![]() |
J. M. Crandell and W. A. Ware Cardiac Toxicity From Phenylpropanolamine Overdose in a Dog J. Am. Anim. Hosp. Assoc., November 1, 2005; 41(6): 413 - 420. [Abstract] [Full Text] [PDF] |
||||
![]() |
K. B. Wallace, E. Hausner, E. Herman, G. D. Holt, J. T. Macgregor, A. L. Metz, E. Murphy, I.Y. Rosenblum, F. D. Sistare, and M. J. York Serum Troponins as Biomarkers of Drug-Induced Cardiac Toxicity Toxicol Pathol, January 1, 2004; 32(1): 106 - 121. [PDF] |
||||
| HOME | HELP | FEEDBACK | SUBSCRIPTIONS | ARCHIVE | SEARCH | TABLE OF CONTENTS |