Clinical Chemistry
HOME HELP FEEDBACK SUBSCRIPTIONS ARCHIVE SEARCH TABLE OF CONTENTS
 QUICK SEARCH:   [advanced]


     


Clinical Chemistry 43: 608-614, 1997;
This Article
Right arrow Full Text
Right arrow Full Text (PDF)
Right arrow Alert me when this article is cited
Right arrow Alert me if a correction is posted
Right arrow Citation Map
Services
Right arrow Email this article to a friend
Right arrow Similar articles in this journal
Right arrow Similar articles in Web of Science
Right arrow Similar articles in PubMed
Right arrow Alert me to new issues of the journal
Right arrow Download to citation manager
Right arrow reprints & permissions
Citing Articles
Right arrow Citing Articles via Web of Science (4)
Right arrow Citing Articles via Google Scholar
Google Scholar
Right arrow Articles by Sadler, W. A.
Right arrow Articles by Turner, J. G.
Right arrow Search for Related Content
PubMed
Right arrow PubMed Citation
Right arrow Articles by Sadler, W. A.
Right arrow Articles by Turner, J. G.
Related Collections
Right arrow Laboratory Management
Right arrow Clinical Immunology
Right arrow Drug Monitoring and Toxicology
Right arrow Endocrinology and Metabolism
(Clinical Chemistry. 1997;43:608-614.)
© 1997 American Association for Clinical Chemistry, Inc.


Articles

A pragmatic approach to estimating total analytical error of immunoassays

William A. Sadlera, Murray H. Smith1, Lynda M. Murray and John G. Turner

Department of Nuclear Medicine, Christchurch Hospital, Private Bag, Christchurch, New Zealand.
1 Department of Mathematics & Statistics, University of Canterbury, Christchurch, New Zealand.
a Author for correspondence. Fax 64 3 364 0869.

Several groups have recently commented on the need for more realistic information on analytical performance of laboratory tests. The term "total analytical error" is sometimes used in this context. However, differing opinions have been expressed on how best to obtain estimates of clinical assay error, as it would be perceived by clinicians. We suggest a pragmatic definition of total analytical error for immunoassays and describe our attempts to estimate it by simple designs in the internal quality-control process. We use results over 29 months from a total serum thyroxine RIA. The most important error sources were those related to calibration materials and operator effects, errors not usually captured by short-term or snapshot experiments.


Key Words: indexing terms: quality control • thyroxine RIA







HOME HELP FEEDBACK SUBSCRIPTIONS ARCHIVE SEARCH TABLE OF CONTENTS
Copyright © 1997 by the American Association for Clinical Chemistry.