Clinical Chemistry
HOME HELP FEEDBACK SUBSCRIPTIONS ARCHIVE SEARCH TABLE OF CONTENTS
 QUICK SEARCH:   [advanced]


     


Clinical Chemistry 43: 619-626, 1997;
This Article
Right arrow Full Text
Right arrow Full Text (PDF)
Right arrow Alert me when this article is cited
Right arrow Alert me if a correction is posted
Services
Right arrow Email this article to a friend
Right arrow Similar articles in this journal
Right arrow Similar articles in Web of Science
Right arrow Similar articles in PubMed
Right arrow Alert me to new issues of the journal
Right arrow Download to citation manager
Right arrow reprints & permissions
Citing Articles
Right arrow Citing Articles via Web of Science (9)
Right arrow Citing Articles via Google Scholar
Google Scholar
Right arrow Articles by Siek, T. J.
Right arrow Articles by Mehary, T. C.
Right arrow Search for Related Content
PubMed
Right arrow PubMed Citation
Right arrow Articles by Siek, T. J.
Right arrow Articles by Mehary, T. C.
Related Collections
Right arrow Laboratory Management
Right arrow Drug Monitoring and Toxicology
(Clinical Chemistry. 1997;43:619-626.)
© 1997 American Association for Clinical Chemistry, Inc.


Articles

Computer-aided identifications of thin-layer chromatographic patterns in broad-spectrum drug screening

Theodore J. Sieka, Corey W. Stradling, Marc W. McCain and Timothy C. Mehary

a Author for correspondence. Fax 215-322-4226.

We have developed a systematic thin-layer chromatographic (TLC) technique for detecting and identifying drugs and drug metabolites on 10-cm-long silica-gel plates with organic binder (fluorescent indicator); a computer program (SPOT CHEK) assists in matching the data from a particular chromatogram with those obtained for known drugs recovered from serum, urine, or other specimens. The plates are developed in a single mobile phase. Visualization and detection reagents used to characterize unknowns include fluorescamine, ferric chloride/perchloric acid/nitric acid, Dragendorff, Marquis, Mandelin, and iodinated Dragendorff solutions, 254 nm ultraviolet light, and vapor from chlorine or hydrochloric acid. Detection limits of 5–200 ng per sample spot were obtained for drugs in the database. The computer program database is based on nine reaction responses plus the plate zone locations for 243 drug substances but requires entry of only one TLC property to generate a matching list. We ran the program with an IBM-compatible 386/486 PC using an MS-DOS operating system (version 6.2).