Clinical Chemistry Link to Randox Laboratories Web Site
HOME HELP FEEDBACK SUBSCRIPTIONS ARCHIVE SEARCH TABLE OF CONTENTS
 QUICK SEARCH:   [advanced]


     


Clinical Chemistry 43: 644-648, 1997;
This Article
Right arrow Full Text
Right arrow Full Text (PDF)
Right arrow Submit an electronic Letter to
the Editor about this paper
Right arrow Alert me when this article is cited
Right arrow Alert me when eLetters are posted
Right arrow Alert me if a correction is posted
Right arrow Citation Map
Services
Right arrow Email this article to a friend
Right arrow Similar articles in this journal
Right arrow Similar articles in ISI Web of Science
Right arrow Similar articles in PubMed
Right arrow Alert me to new issues of the journal
Right arrow Download to citation manager
Right arrow reprints & permissions
Citing Articles
Right arrow Citing Articles via HighWire
Right arrow Citing Articles via ISI Web of Science (23)
Right arrow Citing Articles via Google Scholar
Google Scholar
Right arrow Articles by Doelman, C. J. A.
Right arrow Articles by Penders, T. J.
Right arrow Search for Related Content
PubMed
Right arrow PubMed Citation
Right arrow Articles by Doelman, C. J. A.
Right arrow Articles by Penders, T. J.
Related Collections
Right arrow Hematology
Right arrow Endocrinology and Metabolism
Right arrow Automation and Analytical Techniques
(Clinical Chemistry. 1997;43:644-648.)
© 1997 American Association for Clinical Chemistry, Inc.


Articles

Capillary electrophoresis system for hemoglobin A1c determinations evaluated

Cees J. A. Doelman1,a, Carla W. M. Siebelder1, Wim A. Nijhof1, Cas W. Weykamp1, Jacques Janssens2 and Theo J. Penders1

1 Department of Clinical Chemistry and Hematology, Queen Beatrix Hospital, Beatrixpark 1, 7101 BN Winterswijk, The Netherlands.

2 Analis S.A., 14 Rue Dewez, B 5000 Namur, Belgium.
a Author for correspondence. Fax +31543524265.

Hb A1c is the analyte of choice for monitoring metabolic control in patients with diabetes mellitus. Here we present a new analytical technique for measuring Hb A1c, capillary electrophoresis. The Hb A1c determination is not influenced by the labile Hb A1c fraction or by carbamylated or acetylated hemoglobin derivatives. Also, hemoglobin variants (Hb F, Hb S, and Hb C) do not interfere. This new application of capillary electrophoresis seems to be a valuable analytical tool for measuring Hb A1c in the clinical laboratory.


Key Words: indexing terms: diabetes mellitus • glycohemoglobin • hemoglobin variants




The following articles in journals at HighWire Press have cited this article:


Home page
Clin. Chem.Home page
C. Gay-Bellile, D. Bengoufa, P. Houze, D. Le Carrer, M. Benlakehal, B. Bousquet, B. Gourmel, and T. Le Bricon
Automated Multicapillary Electrophoresis for Analysis of Human Serum Proteins
Clin. Chem., November 1, 2003; 49(11): 1909 - 1915.
[Abstract] [Full Text] [PDF]


Home page
Clin. Chem.Home page
C. W. Weykamp, K. Miedema, T. de Haan, and C. J.A. Doelman
Carbamylated Hemoglobin Interference in Glycohemoglobin Assays
Clin. Chem., March 1, 1999; 45(3): 438 - 440.
[Full Text] [PDF]


Home page
Clin. Chem.Home page
F. Cotton, C. Lin, B. Fontaine, B. Gulbis, J. Janssens, and F. Vertongen
Evaluation of a Capillary Electrophoresis Method for Routine Determination of Hemoglobins A2 and F
Clin. Chem., February 1, 1999; 45(2): 237 - 243.
[Abstract] [Full Text] [PDF]


Home page
Clin. Chem.Home page
N. Mario, B. Baudin, A. Bruneel, J. Janssens, and M. Vaubourdolle
Capillary Zone Electrophoresis for the Diagnosis of Congenital Hemoglobinopathies
Clin. Chem., February 1, 1999; 45(2): 285 - 288.
[Full Text] [PDF]


Home page
Clin. Chem.Home page
S. Blincko and R. Edwards
Non-separation assay for glycohemoglobin
Clin. Chem., June 1, 1998; 44(6): 1302 - 1308.
[Abstract] [Full Text] [PDF]




HOME HELP FEEDBACK SUBSCRIPTIONS ARCHIVE SEARCH TABLE OF CONTENTS
Copyright © 1997 by the American Association for Clinical Chemistry.