Clinical Chemistry
HOME HELP FEEDBACK SUBSCRIPTIONS ARCHIVE SEARCH TABLE OF CONTENTS
 QUICK SEARCH:   [advanced]


     


Clinical Chemistry 43: 663-668, 1997;
This Article
Right arrow Full Text
Right arrow Full Text (PDF)
Right arrow Alert me when this article is cited
Right arrow Alert me if a correction is posted
Right arrow Citation Map
Services
Right arrow Email this article to a friend
Right arrow Similar articles in this journal
Right arrow Similar articles in Web of Science
Right arrow Similar articles in PubMed
Right arrow Alert me to new issues of the journal
Right arrow Download to citation manager
Right arrow reprints & permissions
Citing Articles
Right arrow Citing Articles via HighWire
Right arrow Citing Articles via Web of Science (28)
Right arrow Citing Articles via Google Scholar
Google Scholar
Right arrow Articles by Demacker, P. N. M.
Right arrow Articles by Baadenhuijsen, H.
Right arrow Search for Related Content
PubMed
Right arrow PubMed Citation
Right arrow Articles by Demacker, P. N. M.
Right arrow Articles by Baadenhuijsen, H.
Related Collections
Right arrow Lipids, Lipoproteins, and Cardiovascular Risk Factors
(Clinical Chemistry. 1997;43:663-668.)
© 1997 American Association for Clinical Chemistry, Inc.


Articles

Precipitation methods for high-density lipoprotein cholesterol measurement compared, and final evaluation under routine operating conditions of a method with a low sample-to-reagent ratio

Pierre N. M. Demacker1,a, Marja Hessels2, Helga Toenhake-Dijkstra2 and Henk Baadenhuijsen2

1 Department of Medicine, Division of General Internal Medicine, and
2 Department of Clinical Chemistry, University Hospital Nijmegen, 6500 HB Nijmegen, The Netherlands.
a Author for correspondence. Fax 0031-24-3541346.

We evaluated six precipitation methods for high-density lipoprotein cholesterol (HDL-chol) determination: the heparin/Mn2+precipitation reagent method (Hep), two variants of the phosphotungstic acid/Mg2+ method (Tung-L and Tung-B), the dextran sulfate 50 000/Mg2+ method (Dex), the PEG 6000 method (PEG), and the PEG 6000/dextran sulfate 15 000 (PEG/Dex) method. The Tung-B and PEG/Dex precipitation methods have a low sample/precipitation reagent volume ratio (<0.4). The Tung-B, Dex, PEG, and PEG/Dex methods gave similar values, averaging within 0.1 mmol/L of each other, showing that the precipitation selectivity of these methods is comparable. The precipitation efficiency of Tung-B and Peg/Dex, however, was superior. Ultrafiltration of the supernatants was needed only at triglyceride concentrations >16.4 mmol/L (undiluted sample) or >28.0 mmol/L (sample diluted twofold); however, ultrafiltration without dilution was the most accurate method. Results of Tung-B under routine conditions (33 technicians) agreed well with those of the PEG method for 406 normo- and hyperlipidemic plasma samples. By comparison with the HDL-chol method from the Centers for Disease Control and Prevention, the Tung-B method showed a total error of 10.6%, which fulfills the criteria of the National Cholesterol Education Program for HDL-chol analysis. In conclusion, with motivated personnel, Tung-B is a reliable, cost-effective method for routine HDL-chol analysis.


Key Words: indexing terms: lipoproteins • method comparison • laboratory management




The following articles in journals at HighWire Press have cited this article:


Home page
CirculationHome page
C. G. Magnussen, O. T. Raitakari, R. Thomson, M. Juonala, D. A. Patel, J. S.A. Viikari, J. Marniemi, S. R. Srinivasan, G. S. Berenson, T. Dwyer, et al.
Utility of Currently Recommended Pediatric Dyslipidemia Classifications in Predicting Dyslipidemia in Adulthood: Evidence From the Childhood Determinants of Adult Health (CDAH) Study, Cardiovascular Risk in Young Finns Study, and Bogalusa Heart Study
Circulation, January 1, 2008; 117(1): 32 - 42.
[Abstract] [Full Text] [PDF]


Home page
Ann Rheum DisHome page
C Popa, M G Netea, T Radstake, J W M Van der Meer, A F H Stalenhoef, P L C M van Riel, and P Barerra
Influence of anti-tumour necrosis factor therapy on cardiovascular risk factors in patients with active rheumatoid arthritis
Ann Rheum Dis, February 1, 2005; 64(2): 303 - 305.
[Abstract] [Full Text] [PDF]


Home page
Innate ImmunityHome page
K. Kaneko, R. Ueda, T. Kawata, S. Ishizaka, and T. Yoshimura
LPS binding protein does not participate in the pharmacokinetics of E5564
Innate Immunity, June 1, 2004; 10(3): 185 - 194.
[Abstract] [PDF]


Home page
Am. J. Clin. Nutr.Home page
B. de Roos, M. J Caslake, A. F. Stalenhoef, D. Bedford, P. N. Demacker, M. B Katan, and C. J Packard
The coffee diterpene cafestol increases plasma triacylglycerol by increasing the production rate of large VLDL apolipoprotein B in healthy normolipidemic subjects
Am. J. Clinical Nutrition, January 1, 2001; 73(1): 45 - 52.
[Abstract] [Full Text] [PDF]


Home page
BloodHome page
D. M. W. M. te Loo, L. A. H. Monnens, T. J. A. M. van der Velden, M. A. Vermeer, F. Preyers, P. N. M. Demacker, L. P. W. J. van den Heuvel, and V. W. M. van Hinsbergh
Binding and transfer of verocytotoxin by polymorphonuclear leukocytes in hemolytic uremic syndrome
Blood, June 1, 2000; 95(11): 3396 - 3402.
[Abstract] [Full Text] [PDF]


Home page
Am. J. Clin. Nutr.Home page
L. J van Tits, P. N Demacker, J. de Graaf, H. L Hak-Lemmers, and A. F Stalenhoef
{alpha}-Tocopherol supplementation decreases production of superoxide and cytokines by leukocytes ex vivo in both normolipidemic and hypertriglyceridemic individuals1
Am. J. Clinical Nutrition, February 1, 2000; 71(2): 458 - 464.
[Abstract] [Full Text] [PDF]


Home page
Clin. Chem.Home page
C. Cobbaert, P. G.H. Mulder, H. Baadenhuijsen, L. Zwang, C. W. Weykamp, and P. N.M. Demacker
Survey of Total Error of Precipitation and Homogeneous HDL-Cholesterol Methods and Simultaneous Evaluation of Lyophilized Saccharose-containing Candidate Reference Materials for HDL-Cholesterol
Clin. Chem., March 1, 1999; 45(3): 360 - 370.
[Abstract] [Full Text] [PDF]


Home page
Clin. Chem.Home page
M. Nauck, W. Marz, and H. Wieland
New immunoseparation-based homogeneous assay for HDL-cholesterol compared with three homogeneous and two heterogeneous methods for HDL-cholesterol
Clin. Chem., July 1, 1998; 44(7): 1443 - 1451.
[Abstract] [Full Text] [PDF]




HOME HELP FEEDBACK SUBSCRIPTIONS ARCHIVE SEARCH TABLE OF CONTENTS
Copyright © 1997 by the American Association for Clinical Chemistry.