Clinical Chemistry Link to Randox Laboratories Web Site
HOME HELP FEEDBACK SUBSCRIPTIONS ARCHIVE SEARCH TABLE OF CONTENTS
 QUICK SEARCH:   [advanced]


     


Clinical Chemistry 43: 801-807, 1997;
This Article
Right arrow Full Text
Right arrow Full Text (PDF)
Right arrow Submit an electronic Letter to
the Editor about this paper
Right arrow Alert me when this article is cited
Right arrow Alert me when eLetters are posted
Right arrow Alert me if a correction is posted
Right arrow Citation Map
Services
Right arrow Email this article to a friend
Right arrow Similar articles in this journal
Right arrow Similar articles in ISI Web of Science
Right arrow Similar articles in PubMed
Right arrow Alert me to new issues of the journal
Right arrow Download to citation manager
Right arrow reprints & permissions
Citing Articles
Right arrow Citing Articles via HighWire
Right arrow Citing Articles via ISI Web of Science (9)
Right arrow Citing Articles via Google Scholar
Google Scholar
Right arrow Articles by Ferrara, F.
Right arrow Articles by Banfi, G.
Right arrow Search for Related Content
PubMed
Right arrow PubMed Citation
Right arrow Articles by Ferrara, F.
Right arrow Articles by Banfi, G.
Related Collections
Right arrow Endocrinology and Metabolism
Right arrow Automation and Analytical Techniques
(Clinical Chemistry. 1997;43:801-807.)
© 1997 American Association for Clinical Chemistry, Inc.


Articles

Automation of human sperm cell analysis by flow cytometry

Fulvio Ferrara1, Rita Daverio1, Giuliano Mazzini2, Pierangelo Bonini1 and Giuseppe Banfi1,a

1 Department of Laboratory Medicine, Scientific Institute H.S. Raffaele, via Olgettina no. 60, 20132, Milan, Italy.

2 Department of Histochemistry, National Research Council, Pavia, Italy.
a Author for correspondence. Fax 39-2-26432640.

Semen sample analysis is routinely performed by microscopical evaluation and manual techniques by laboratory operators; the analysis is affected by a wide imprecision related to variability among observers, influencing its clinical validity. Our aim was to automate sperm analysis with the use of flow cytometry for evaluation of cell counts and typing and with the use of a new membrane-permeant nucleic acid stain for evaluation of sperm viability. Statistical analysis of the comparison between manual and automated methods for sperm counts was performed by the Bland and Altman method; the mean difference was 0.243 x 106 sperms/mL. The precision of the flow cytometric analysis was evaluated with whole sperm; the between-run CV was 7.5% and the within-run CV was 2.5%. Data observed suggest that flow cytometric sperm analysis, with high precision and accuracy and low costs, can be proposed for routine use in clinical laboratories.


Key Words: indexing terms: vital staining • semen analysis




The following articles in journals at HighWire Press have cited this article:


Home page
Hum ReprodHome page
S. Perticarari, G. Ricci, M. Granzotto, R. Boscolo, C. Pozzobon, S. Guarnieri, A. Sartore, and G. Presani
A new multiparameter flow cytometric method for human semen analysis
Hum. Reprod., February 1, 2007; 22(2): 485 - 494.
[Abstract] [Full Text] [PDF]


Home page
Hum ReprodHome page
G. Ricci, G. Presani, S. Guaschino, R. Simeone, and S. Perticarari
Leukocyte detection in human semen using flow cytometry
Hum. Reprod., June 1, 2000; 15(6): 1329 - 1337.
[Abstract] [Full Text] [PDF]




HOME HELP FEEDBACK SUBSCRIPTIONS ARCHIVE SEARCH TABLE OF CONTENTS
Copyright © 1997 by the American Association for Clinical Chemistry.