Clinical Chemistry Link to Randox Laboratories Web Site
HOME HELP FEEDBACK SUBSCRIPTIONS ARCHIVE SEARCH TABLE OF CONTENTS
 QUICK SEARCH:   [advanced]


     


Clinical Chemistry 43: 1033-1039, 1997;
This Article
Right arrow Full Text
Right arrow Full Text (PDF)
Right arrow Submit an electronic Letter to
the Editor about this paper
Right arrow Alert me when this article is cited
Right arrow Alert me when eLetters are posted
Right arrow Alert me if a correction is posted
Services
Right arrow Email this article to a friend
Right arrow Similar articles in this journal
Right arrow Similar articles in ISI Web of Science
Right arrow Similar articles in PubMed
Right arrow Alert me to new issues of the journal
Right arrow Download to citation manager
Right arrow reprints & permissions
Citing Articles
Right arrow Citing Articles via HighWire
Right arrow Citing Articles via ISI Web of Science (13)
Right arrow Citing Articles via Google Scholar
Google Scholar
Right arrow Articles by Bowers, L. D.
Right arrow Articles by Borts, D. J.
Right arrow Search for Related Content
PubMed
Right arrow PubMed Citation
Right arrow Articles by Bowers, L. D.
Right arrow Articles by Borts, D. J.
Related Collections
Right arrow Drug Monitoring and Toxicology
Right arrow Automation and Analytical Techniques
(Clinical Chemistry. 1997;43:1033-1039.)
© 1997 American Association for Clinical Chemistry, Inc.


Articles

Evaluation of selected-ion storage ion-trap mass spectrometry for detecting urinary anabolic agents

Larry D. Bowersa and David J. Borts

Athletic Drug Testing and Toxicology Laboratory, Indiana University Medical Center, Medical Science Bldg. A-128, 635 Barnhill Dr., Indianapolis, IN 46202-5120.
a Author for correspondence. Fax 317-274-3223; e-mail lbowers{at}iupui.edu

Limits of detection are important issues for GC/MS screening for anabolic agents and for confirmation of various drugs of abuse. We compared a quadrupole ion trap (QIT) operated in two different selected-ion storage modes and a quadrupole mass filter (QMF) operated in the selected-ion monitoring mode. Results with the model compound tetrachlorobenzene indicate that, for simultaneous monitoring of more than four ions, the QIT operated in a frequency-modulated selected-ion storage mode has better limits of detection than the QMF. Use of a single-ion storage technique gave results similar to those of the QMF. We also evaluated both QIT selected-ion storage approaches for the limits of detection of the trimethylsilyl derivatives of four anabolic steroid metabolites and the ß-agonist clenbuterol. We found no improvement in detection limits over that of a similar method with selected-ion monitoring and a QMF when four anabolic steroid metabolites and clenbuterol were extracted from a urine matrix. The lack of improvement in the limit of detection resulted from matrix background signals at masses similar to those of the steroids.


Key Words: indexing terms: quadrupole ion trap • quadrupole mass filter • GC-MS • abused drugs • clenbuterol




The following articles in journals at HighWire Press have cited this article:


Home page
Clin. Chem.Home page
L. D. Bowers
Analytical advances in detection of performance-enhancing compounds
Clin. Chem., July 1, 1997; 43(7): 1299 - 1304.
[Abstract] [Full Text] [PDF]


Home page
Clin. Chem.Home page
R. L. Fitzgerald, D. A. Herold, and A. L. Yergey
Trade-offs in Mass Spectrometry
Clin. Chem., June 1, 1997; 43(6): 915 - 915.
[Full Text] [PDF]




HOME HELP FEEDBACK SUBSCRIPTIONS ARCHIVE SEARCH TABLE OF CONTENTS