Clinical Chemistry AACC Online Job Center
HOME HELP FEEDBACK SUBSCRIPTIONS ARCHIVE SEARCH TABLE OF CONTENTS
 QUICK SEARCH:   [advanced]


     


Clinical Chemistry 43: 1129-1141, 1997;
This Article
Right arrow Full Text
Right arrow Full Text (PDF)
Right arrow Submit an electronic Letter to
the Editor about this paper
Right arrow Alert me when this article is cited
Right arrow Alert me when eLetters are posted
Right arrow Alert me if a correction is posted
Right arrow Citation Map
Services
Right arrow Email this article to a friend
Right arrow Similar articles in this journal
Right arrow Similar articles in PubMed
Right arrow Alert me to new issues of the journal
Right arrow Download to citation manager
Right arrow reprints & permissions
Citing Articles
Right arrow Citing Articles via HighWire
Right arrow Citing Articles via ISI Web of Science (115)
Right arrow Citing Articles via Google Scholar
Google Scholar
Right arrow Articles by Rashed, M. S.
Right arrow Articles by Ozand, P. T.
Right arrow Search for Related Content
PubMed
Right arrow PubMed Citation
Right arrow Articles by Rashed, M. S.
Right arrow Articles by Ozand, P. T.
Related Collections
Right arrow Pediatric Clinical Chemistry
Right arrow Molecular Diagnostics and Genetics
Right arrow Automation and Analytical Techniques
(Clinical Chemistry. 1997;43:1129-1141.)
© 1997 American Association for Clinical Chemistry, Inc.


Articles

Screening blood spots for inborn errors of metabolism by electrospray tandem mass spectrometry with a microplate batch process and a computer algorithm for automated flagging of abnormal profiles

Mohamed S. Rashed1,a, Martin P. Bucknall1, Douglas Little1, Amin Awad1, Minnie Jacob1, Mohamed Alamoudi1, Mona Alwattar1 and Pinar T. Ozand1,2

1 Departments of Biological and Medical Research and
2 Pediatrics, King Faisal Specialist Hospital and Research Centre, PO Box 3354, Riyadh 11211, Saudi Arabia.
a Author for correspondence. Fax 966-1-442-7858; e-mail rashed{at}kfshrc.edu.sa

Metabolic profiling of amino acids and acylcarnitines from blood spots by automated electrospray tandem mass spectrometry (ESI-MS/MS) is a powerful diagnostic tool for inborn errors of metabolism. New approaches to sample preparation and data interpretation have helped establish the methodology as a robust, high-throughput neonatal screening method. We introduce an efficient 96-well-microplate batch process for blood-spot sample preparation, with which we can obtain high-quality profiles from 500-1000 samples per day per instrument. A computer-assisted metabolic profiling algorithm automatically flags abnormal profiles. We selected diagnostic parameters for the algorithm by comparing profiles from patients with known metabolic disorders and those from normal newborns. Reference range and cutoff values for the diagnostic parameters were established by measuring either metabolite concentrations or peak ratios of certain metabolite pairs. Rigorous testing of the algorithm demonstrates its outstanding clinical sensitivity in flagging abnormal profiles and its high cumulative specificity.


Key Words: indexing terms: amino acids • organic acidemia • defects of fatty acid oxidation • inherited disorders • neonatal screening




The following articles in journals at HighWire Press have cited this article:


Home page
Clin. Chem.Home page
K. A. Strnadova, M. Holub, A. Muhl, G. Heinze, R. Ratschmann, H. Mascher, S. Stockler-Ipsiroglu, F. Waldhauser, F. Votava, J. Lebl, et al.
Long-Term Stability of Amino Acids and Acylcarnitines in Dried Blood Spots
Clin. Chem., April 1, 2007; 53(4): 717 - 722.
[Abstract] [Full Text] [PDF]


Home page
Clin. Chem.Home page
D. S. Millington
Newborn Screening for Lysosomal Storage Disorders
Clin. Chem., May 1, 2005; 51(5): 808 - 809.
[Full Text] [PDF]


Home page
Clin. Chem.Home page
C. T. Cavedon, P. Bourdoux, K. Mertens, H. V. Van Thi, N. Herremans, C. de Laet, and P. Goyens
Age-Related Variations in Acylcarnitine and Free Carnitine Concentrations Measured by Tandem Mass Spectrometry
Clin. Chem., April 1, 2005; 51(4): 745 - 752.
[Abstract] [Full Text] [PDF]


Home page
Clin. Chem.Home page
S. H. Korman, B. S. Andresen, A. Zeharia, A. Gutman, A. Boneh, and J. J. Pitt
2-Ethylhydracrylic Aciduria in Short/Branched-Chain Acyl-CoA Dehydrogenase Deficiency: Application to Diagnosis and Implications for the R-Pathway of Isoleucine Oxidation
Clin. Chem., March 1, 2005; 51(3): 610 - 617.
[Abstract] [Full Text] [PDF]


Home page
J. Biol. Chem.Home page
W. Yu, X. Liang, R. E. Ensenauer, J. Vockley, L. Sweetman, and H. Schulz
Leaky {beta}-Oxidation of a trans-Fatty Acid: INCOMPLETE {beta}-OXIDATION OF ELAIDIC ACID IS DUE TO THE ACCUMULATION OF 5-TRANS-TETRADECENOYL-CoA AND ITS HYDROLYSIS AND CONVERSION TO 5-TRANS-TETRADECENOYLCARNITINE IN THE MATRIX OF RAT MITOCHONDRIA
J. Biol. Chem., December 10, 2004; 279(50): 52160 - 52167.
[Abstract] [Full Text] [PDF]


Home page
J. Biol. Chem.Home page
T. Dai, G. A. Abou-Rjaily, Q. Y. Al-Share', Y. Yang, M. A. Fernstrom, A. M. DeAngelis, A. D. Lee, L. Sweetman, A. Amato, M. Pasquali, et al.
Interaction between Altered Insulin and Lipid Metabolism in CEACAM1-inactive Transgenic Mice
J. Biol. Chem., October 22, 2004; 279(43): 45155 - 45161.
[Abstract] [Full Text] [PDF]


Home page
NeurologyHome page
Y. Ohashi, Y. Hasegawa, K. Murayama, M. Ogawa, T. Hasegawa, M. Kawai, N. Sakata, K. Yoshida, H. Yarita, K. Imai, et al.
A new diagnostic test for VLCAD deficiency using immunohistochemistry
Neurology, June 22, 2004; 62(12): 2209 - 2213.
[Abstract] [Full Text] [PDF]


Home page
J. Biol. Chem.Home page
H. Peters, M. Nefedov, J. Sarsero, J. Pitt, K. J. Fowler, S. Gazeas, S. G. Kahler, and P. A. Ioannou
A Knock-out Mouse Model for Methylmalonic Aciduria Resulting in Neonatal Lethality
J. Biol. Chem., December 26, 2003; 278(52): 52909 - 52913.
[Abstract] [Full Text] [PDF]


Home page
Clin. Chem.Home page
D. H. Chace, T. A. Kalas, and E. W. Naylor
Use of Tandem Mass Spectrometry for Multianalyte Screening of Dried Blood Specimens from Newborns
Clin. Chem., November 1, 2003; 49(11): 1797 - 1817.
[Abstract] [Full Text] [PDF]


Home page
Clin. Chem.Home page
J. J. Pitt, M. Eggington, and S. G. Kahler
Comprehensive Screening of Urine Samples for Inborn Errors of Metabolism by Electrospray Tandem Mass Spectrometry
Clin. Chem., November 1, 2002; 48(11): 1970 - 1980.
[Abstract] [Full Text] [PDF]


Home page
Clin. Chem.Home page
B. G. Keevil, D. P. Tierney, D. P. Cooper, and M. R. Morris
Rapid Liquid Chromatography-Tandem Mass Spectrometry Method for Routine Analysis of Cyclosporin A Over an Extended Concentration Range
Clin. Chem., January 1, 2002; 48(1): 69 - 76.
[Abstract] [Full Text] [PDF]


Home page
Clin. Chem.Home page
L. Sweetman
Newborn Screening by Tandem Mass Spectrometry: Gaining Experience
Clin. Chem., November 1, 2001; 47(11): 1937 - 1938.
[Full Text] [PDF]


Home page
Clin. Chem.Home page
T. H. Zytkovicz, E. F. Fitzgerald, D. Marsden, C. A. Larson, V. E. Shih, D. M. Johnson, A. W. Strauss, A. M. Comeau, R. B. Eaton, and G. F. Grady
Tandem Mass Spectrometric Analysis for Amino, Organic, and Fatty Acid Disorders in Newborn Dried Blood Spots: A Two-Year Summary from the New England Newborn Screening Program
Clin. Chem., November 1, 2001; 47(11): 1945 - 1955.
[Abstract] [Full Text] [PDF]


Home page
Am. J. Clin. Nutr.Home page
S. M Watkins, B. D Hammock, J. W Newman, and J B. German
Individual metabolism should guide agriculture toward foods for improved health and nutrition
Am. J. Clinical Nutrition, September 1, 2001; 74(3): 283 - 286.
[Abstract] [Full Text]


Home page
Clin. Chem.Home page
U. G. Jensen, N. J. Brandt, E. Christensen, F. Skovby, B. Norgaard-Pedersen, and H. Simonsen
Neonatal Screening for Galactosemia by Quantitative Analysis of Hexose Monophosphates Using Tandem Mass Spectrometry: A Retrospective Study
Clin. Chem., August 1, 2001; 47(8): 1364 - 1372.
[Abstract] [Full Text] [PDF]


Home page
Clin. Chem.Home page
N. B. Roberts, A. B. Amara, M. Morris, and B. N. Green
Long-Term Evaluation of Electrospray Ionization Mass Spectrometric Analysis of Glycated Hemoglobin
Clin. Chem., February 1, 2001; 47(2): 316 - 321.
[Abstract] [Full Text] [PDF]


Home page
Clin. Chem.Home page
T. Ito, A. B.P. van Kuilenburg, A. H. Bootsma, A. J. Haasnoot, A. van Cruchten, Y. Wada, and A. H. van Gennip
Rapid Screening of High-Risk Patients for Disorders of Purine and Pyrimidine Metabolism Using HPLC-Electrospray Tandem Mass Spectrometry of Liquid Urine or Urine-soaked Filter Paper Strips
Clin. Chem., April 1, 2000; 46(4): 445 - 452.
[Abstract] [Full Text] [PDF]


Home page
BMJHome page
I. Mushtaq, S. Logan, M. Morris, A. W Johnson, A. M Wade, D. Kelly, and P. T Clayton
Screening of newborn infants for cholestatic hepatobiliary disease with tandem mass spectrometry • Commentary: What is tandem mass spectrometry?
BMJ, August 21, 1999; 319(7208): 471 - 477.
[Abstract] [Full Text]


Home page
J Child NeurolHome page
M. Al Essa, N. A. Sakati, O. Dabbagh, S. Joshi, E. A. Al Jishi, M. S. Rashed, J. E. Powe, and P. T. Ozand
Inborn Error of Vitamin B12 Metabolism: A Treatable Cause of Childhood Dementia/Paralysis
J Child Neurol, May 1, 1998; 13(5): 239 - 243.
[PDF]


Home page
Clin. Chem.Home page
M. Tuchman
Molecular Diagnosis of Medium-Chain Acyl-CoA Dehydrogenase Deficiency by Oligonucleotide Ligation Assay
Clin. Chem., January 1, 1998; 44(1): 10 - 11.
[Full Text] [PDF]




HOME HELP FEEDBACK SUBSCRIPTIONS ARCHIVE SEARCH TABLE OF CONTENTS
Copyright © 1997 by the American Association for Clinical Chemistry.