Clinical Chemistry
HOME HELP FEEDBACK SUBSCRIPTIONS ARCHIVE SEARCH TABLE OF CONTENTS
 QUICK SEARCH:   [advanced]


     


Clinical Chemistry 43: 1215-1222, 1997;
This Article
Right arrow Full Text
Right arrow Full Text (PDF)
Right arrow Alert me when this article is cited
Right arrow Alert me if a correction is posted
Right arrow Citation Map
Services
Right arrow Email this article to a friend
Right arrow Similar articles in this journal
Right arrow Similar articles in Web of Science
Right arrow Similar articles in PubMed
Right arrow Alert me to new issues of the journal
Right arrow Download to citation manager
Right arrow reprints & permissions
Citing Articles
Right arrow Citing Articles via HighWire
Right arrow Citing Articles via Web of Science (12)
Right arrow Citing Articles via Google Scholar
Google Scholar
Right arrow Articles by van den Besselaar, A. M. H. P.
Right arrow Articles by Bertina, R. M.
Right arrow Search for Related Content
PubMed
Right arrow PubMed Citation
Right arrow Articles by van den Besselaar, A. M. H. P.
Right arrow Articles by Bertina, R. M.
Related Collections
Right arrow Laboratory Management
Right arrow Hemostasis and Thrombosis
Right arrow Hematology
(Clinical Chemistry. 1997;43:1215-1222.)
© 1997 American Association for Clinical Chemistry, Inc.


Articles

Preparation of lyophilized partial thromboplastin time reagent composed of synthetic phospholipids: usefulness for monitoring heparin therapy

Anton M. H. P. van den Besselaara, Jacoline Neuteboom, Joyce Meeuwisse-Braun and Rogier M. Bertina

Hemostasis and Thrombosis Research Centre, Department of Hematology, Leiden University Hospital, Bldg. 1, C2-R, P.O. Box 9600, 2300 RC Leiden, The Netherlands.
a Author for correspondence. Fax +31 71 5266755.

To contribute to the development of a reference reagent for monitoring heparin therapy, a lyophilized partial thromboplastin time (PTT) reagent was prepared from synthetic dioleoylphosphatidylcholine, dioleoylphosphatidylserine, and dioleoylphosphatidylethanolamine, with colloidal silica as activator. The reagent, coded 91/558, was contained in sealed glass ampoules; it deteriorated in a heat degradation experiment, but its activity remained constant for at least 4 years when stored at -70 °C. Within- and between-run precision with this reagent complied with the requirements proposed by the International Committee for Standardization in Haematology (ICSH) Panel on PTT. The response of this reagent and of two other reagents to heparin added to pooled normal plasma was nonlinear. Citrated samples from 58 patients receiving intravenous heparin and from 24 apparently healthy volunteers were tested with reagent 91/558, with Automated APTT (Organon Teknika), with Manchester APTT reagent, with an anti-factor Xa assay, and with an anti-factor IIa assay. The correlation of APTT with anti-Xa and anti-IIa activity was poor. The best correlation was observed between reagent 91/558 and the Organon Teknika reagent. Correlations were improved when individual patients' samples were replaced by pooled plasmas from heparinized patients, in whom the effect of oral anticoagulation was minimal. These results suggest that preparation of a lyophilized synthetic phospholipid reagent is feasible for use in monitoring heparin therapy.


Key Words: indexing terms: anticoagulants • standardization




The following articles in journals at HighWire Press have cited this article:


Home page
Clin. Chem.Home page
C. Eby
Standardization of APTT Reagents for Heparin Therapy Monitoring: Urgent or Fading Priority?
Clin. Chem., July 1, 1997; 43(7): 1105 - 1107.
[Full Text] [PDF]




HOME HELP FEEDBACK SUBSCRIPTIONS ARCHIVE SEARCH TABLE OF CONTENTS
Copyright © 1997 by the American Association for Clinical Chemistry.