Clinical Chemistry
HOME HELP FEEDBACK SUBSCRIPTIONS ARCHIVE SEARCH TABLE OF CONTENTS
 QUICK SEARCH:   [advanced]


     


Clinical Chemistry 44: 78-85, 1998;
This Article
Right arrow Full Text
Right arrow Full Text (PDF)
Right arrow Alert me when this article is cited
Right arrow Alert me if a correction is posted
Right arrow Citation Map
Services
Right arrow Email this article to a friend
Right arrow Similar articles in this journal
Right arrow Similar articles in Web of Science
Right arrow Similar articles in PubMed
Right arrow Alert me to new issues of the journal
Right arrow Download to citation manager
Right arrow reprints & permissions
Citing Articles
Right arrow Citing Articles via HighWire
Right arrow Citing Articles via Web of Science (11)
Right arrow Citing Articles via Google Scholar
Google Scholar
Right arrow Articles by Kertesz, G.
Right arrow Articles by Jean, F.
Right arrow Search for Related Content
PubMed
Right arrow PubMed Citation
Right arrow Articles by Kertesz, G.
Right arrow Articles by Jean, F.
Related Collections
Right arrow Endocrinology and Metabolism
(Clinical Chemistry. 1998;44:78-85.)
© 1998 American Association for Clinical Chemistry, Inc.


Endocrinology and Metabolism

Immunoradiometric assay of succinylated corticotropin: an improved method for quantification of ACTH

Gilles Kertesza, Béatrice Bourcier, Hélène Cailla, and Frédéric Jean

a Author for correspondence. Fax 334 91 17 27 40.

In this paper we describe the development and the evaluation of a new type of immunoassay for human corticotropin (ACTH). We succeeded, by using an original approach based upon immunization with ACTH derivatized with succinic anhydride, in raising monoclonal antibodies against this poorly immunogenic peptide. Three of the antibodies were selected to develop an immunoassay for ACTH. The assay requires the prior succinylation of the plasma samples for optimal sensitivity and specificity. This acylation treatment is fast, reproducible, and, in addition, improves the stability of the ACTH molecule in plasma, thus facilitating sample handling. The assay is performed in only 3 h with a detection limit of 0.7 ng/L. Analytical evaluation showed excellent specificity, reproducibility, and reliability. A comparison with two commonly used but time-consuming ACTH IRMAs was carried out by assaying several plasma samples in parallel and gave in both cases very good correlation.




The following articles in journals at HighWire Press have cited this article:


Home page
Arch Intern MedHome page
M. Boscaro, L. Barzon, and N. Sonino
The Diagnosis of Cushing's Syndrome: Atypical Presentations and Laboratory Shortcomings
Arch Intern Med, November 13, 2000; 160(20): 3045 - 3053.
[Abstract] [Full Text] [PDF]




HOME HELP FEEDBACK SUBSCRIPTIONS ARCHIVE SEARCH TABLE OF CONTENTS
Copyright © 1998 by the American Association for Clinical Chemistry.