Clinical Chemistry Link to Randox Laboratories Web Site
HOME HELP FEEDBACK SUBSCRIPTIONS ARCHIVE SEARCH TABLE OF CONTENTS
 QUICK SEARCH:   [advanced]


     


Clinical Chemistry 44: 226-231, 1998;
This Article
Right arrow Full Text
Right arrow Full Text (PDF)
Right arrow Submit an electronic Letter to
the Editor about this paper
Right arrow Alert me when this article is cited
Right arrow Alert me when eLetters are posted
Right arrow Alert me if a correction is posted
Right arrow Citation Map
Services
Right arrow Email this article to a friend
Right arrow Similar articles in this journal
Right arrow Similar articles in ISI Web of Science
Right arrow Similar articles in PubMed
Right arrow Alert me to new issues of the journal
Right arrow Download to citation manager
Right arrow reprints & permissions
Citing Articles
Right arrow Citing Articles via ISI Web of Science (17)
Right arrow Citing Articles via Google Scholar
Google Scholar
Right arrow Articles by Pérez, L. F.
Right arrow Articles by Tutor, J. C.
Right arrow Search for Related Content
PubMed
Right arrow PubMed Citation
Right arrow Articles by Pérez, L. F.
Right arrow Articles by Tutor, J. C.
Related Collections
Right arrow Proteomics and Protein Markers
Right arrow Automation and Analytical Techniques
(Clinical Chemistry. 1998;44:226-231.)
© 1998 American Association for Clinical Chemistry, Inc.


Enzymes and Protein Markers

Assay of ß-N-acetylhexosaminidase isoenzymes in different biological specimens by means of determination of their activation energies

Luis F. Pérez, and J. Carlos Tutora

a Author for correspondence. Fax Int + 34-81-57 01 02.

The activation energy (Ea) of ß-N-acetylhexosaminidase (Hex, EC 3.2.1.52) was determined with 3,3'-dichlorophenylsulfonphthaleinyl-N-acetyl-ß-D-glucosaminide as substrate, with a much higher value being found for the Hex B isoenzyme (Ea = 75.1 kJ/mol) than for the Hex A isoenzyme (Ea = 41.8 kJ/mol). This fact allowed for the development of a fast and reliable thermodynamic method to determine the isoenzyme composition of Hex in different biological specimens (serum/plasma, saliva, cerebrospinal fluid, seminal plasma, urine, and leukocyte lysates). The results in serum given by the proposed method may be superimposed upon those obtained by the heat inactivation assay of O'Brien et al. (N Engl J Med 1970;273:15–20), and the catalytic activity calculated for Hex A offers a good correlation with that obtained by using the specific substrate 4-methylumbelliferyl-N-acetyl-ß-D-glucosaminide-6 sulfate (n = 25, r = 0.953).







HOME HELP FEEDBACK SUBSCRIPTIONS ARCHIVE SEARCH TABLE OF CONTENTS
Copyright © 1998 by the American Association for Clinical Chemistry.