Clinical Chemistry
HOME HELP FEEDBACK SUBSCRIPTIONS ARCHIVE SEARCH TABLE OF CONTENTS
 QUICK SEARCH:   [advanced]


     


Clinical Chemistry 44: 817-824, 1998;
This Article
Right arrow Full Text
Right arrow Full Text (PDF)
Right arrow Alert me when this article is cited
Right arrow Alert me if a correction is posted
Right arrow Citation Map
Services
Right arrow Email this article to a friend
Right arrow Similar articles in this journal
Right arrow Similar articles in Web of Science
Right arrow Similar articles in PubMed
Right arrow Alert me to new issues of the journal
Right arrow Download to citation manager
Right arrow reprints & permissions
Citing Articles
Right arrow Citing Articles via HighWire
Right arrow Citing Articles via Web of Science (35)
Right arrow Citing Articles via Google Scholar
Google Scholar
Right arrow Articles by Haldimann, M.
Right arrow Articles by Gerber, H.
Right arrow Search for Related Content
PubMed
Right arrow PubMed Citation
Right arrow Articles by Haldimann, M.
Right arrow Articles by Gerber, H.
Related Collections
Right arrow Nutrition
Right arrow Endocrinology and Metabolism
Right arrow Automation and Analytical Techniques
(Clinical Chemistry. 1998;44:817-824.)
© 1998 American Association for Clinical Chemistry, Inc.


Automation and Analytical Techniques

Direct determination of urinary iodine by inductively coupled plasma mass spectrometry using isotope dilution with iodine-129

Max Haldimann1,a, Bernhard Zimmerli1, Claudine Als2, and Hans Gerber3

1 Swiss Federal Office of Public Health, Division of Food Science, Section of Food Chemistry and Analysis, 3003 Bern, Switzerland.

2 University of Bern, Inselspital, Department of Pathology, 3010 Bern, Switzerland.

3 University Hospital, Inselspital, Department of Clinical Chemistry, 3010 Bern, Switzerland.
a Author for correspondence. Fax (41) 31 322 95 74; e-mail max.haldimann{at}bag.admin.ch.

An inductively coupled mass spectrometric method was developed for the direct determination of iodine in urine. The application of isotope dilution analysis with added 129I offers new possibilities for automatic and accurate determinations. The sample preparation consists of dilution with an ammonia solution containing 129I. The validation was made by comparison with the results obtained in another laboratory by a spectrophotometric method based on the Sandell–Kolthoff reaction. Different regression models, including maximum likelihood estimation, were used to compare the methods. None of the models revealed analytical bias between the two methods. The urine samples analyzed for validation were from three persons previously exposed to an iodine bath and covered a concentration range of 0.2 to 2.8 µmol/L. A detection limit of 0.02 µmol/L, a within-run CV of 2.5%, and a between-run CV of 11.9% were estimated for the proposed method.




The following articles in journals at HighWire Press have cited this article:


Home page
Am. J. Clin. Nutr.Home page
M. B Zimmermann, Y. Ito, S. Y Hess, K. Fujieda, and L. Molinari
High thyroid volume in children with excess dietary iodine intakes
Am. J. Clinical Nutrition, April 1, 2005; 81(4): 840 - 844.
[Abstract] [Full Text] [PDF]


Home page
J. Clin. Endocrinol. Metab.Home page
C. Als, A. Helbling, K. Peter, M. Haldimann, B. Zimmerli, and H. Gerber
Urinary Iodine Concentration follows a Circadian Rhythm: A Study with 3023 Spot Urine Samples in Adults and Children
J. Clin. Endocrinol. Metab., April 1, 2000; 85(4): 1367 - 1369.
[Abstract] [Full Text]


Home page
Clin. Chem.Home page
T. Ohashi, M. Yamaki, C. S. Pandav, M. G. Karmarkar, and M. Irie
Simple Microplate Method for Determination of Urinary Iodine
Clin. Chem., April 1, 2000; 46(4): 529 - 536.
[Abstract] [Full Text] [PDF]




HOME HELP FEEDBACK SUBSCRIPTIONS ARCHIVE SEARCH TABLE OF CONTENTS