Clinical Chemistry Link to Randox Laboratories Web Site
HOME HELP FEEDBACK SUBSCRIPTIONS ARCHIVE SEARCH TABLE OF CONTENTS
 QUICK SEARCH:   [advanced]


     


Clinical Chemistry 44: 1680-1684, 1998;
This Article
Right arrow Full Text
Right arrow Full Text (PDF)
Right arrow Submit an electronic Letter to
the Editor about this paper
Right arrow Alert me when this article is cited
Right arrow Alert me when eLetters are posted
Right arrow Alert me if a correction is posted
Right arrow Citation Map
Services
Right arrow Email this article to a friend
Right arrow Similar articles in this journal
Right arrow Similar articles in ISI Web of Science
Right arrow Similar articles in PubMed
Right arrow Alert me to new issues of the journal
Right arrow Download to citation manager
Right arrow reprints & permissions
Citing Articles
Right arrow Citing Articles via HighWire
Right arrow Citing Articles via ISI Web of Science (8)
Right arrow Citing Articles via Google Scholar
Google Scholar
Right arrow Articles by Dalaman, G.
Right arrow Articles by Yalçin, A. S.
Right arrow Search for Related Content
PubMed
Right arrow PubMed Citation
Right arrow Articles by Dalaman, G.
Right arrow Articles by Yalçin, A. S.
Related Collections
Right arrow General Clinical Chemistry
Right arrow Evidence Based Laboratory Medicine and Test Utilization
(Clinical Chemistry. 1998;44:1680-1684.)
© 1998 American Association for Clinical Chemistry, Inc.


General Clinical Chemistry

Early detection of peritonitis in continuous ambulatory peritoneal dialysis patients by use of chemiluminescence: evaluation of diagnostic accuracy by receiver-operating characteristic curve analysis

Gönül Dalaman1, Goncagül Haklar1, Armand Sipahiu2, Çetin Özener2, Emel Akoglu2, and A. Süha Yalçin1,a

Departments of
1 Biochemistry and
2 Nephrology, School of Medicine, Marmara University Istanbul, 81326 HaydarpaIsa-Istanbul, Turkey.
a Author for correspondence. Fax 90-216-418-1047; e-mail ayalcin{at}marun.edu.tr.

Continuous ambulatory peritoneal dialysis (CAPD) is now a widely accepted treatment for end-stage renal disease. However, the high incidence of peritonitis is a major complication of CAPD. Polymorphonuclear leukocytes (PMNs) play a major role in antimicrobial response of the host. During phagocytosis, the PMNs undergo a striking increase in oxidative metabolism, known as the respiratory burst, and emit light as chemiluminescence (CL). CL is thus a sensitive measure of PMN oxidative potential and correlates well with antimicrobial activity. In view of the observation of increased susceptibility to infection in CAPD patients, we have studied lucigenin- and luminol-enhanced CL in peritoneal fluids of these patients and assessed the diagnostic accuracy of these tests by ROC curve analysis. ROC curves showed diagnostic accuracies for both tests that were superior to counts of PMNs in the dialysis fluid (P <0.001). At selected cutoff values of 150 000 cpm/vial for lucigenin CL and 600 000 cpm/vial for luminol CL, sensitivities were 100%. Specificities for lucigenin and luminol CL were 89% and 80%, respectively. Our results suggest that CL measurements can be used as an early marker for the presence of infection in CAPD patients.




The following articles in journals at HighWire Press have cited this article:


Home page
Nephrol Dial TransplantHome page
J. Penders, T. Fiers, A. M. Dhondt, G. Claeys, and J. R. Delanghe
Automated flow cytometry analysis of peritoneal dialysis fluid
Nephrol. Dial. Transplant., February 1, 2004; 19(2): 463 - 468.
[Abstract] [Full Text] [PDF]




HOME HELP FEEDBACK SUBSCRIPTIONS ARCHIVE SEARCH TABLE OF CONTENTS
Copyright © 1998 by the American Association for Clinical Chemistry.