Clinical Chemistry AACC Online Job Center
HOME HELP FEEDBACK SUBSCRIPTIONS ARCHIVE SEARCH TABLE OF CONTENTS
 QUICK SEARCH:   [advanced]


     


Clinical Chemistry 44: 1974-1979, 1998;
This Article
Right arrow Full Text
Right arrow Full Text (PDF)
Right arrow Submit an electronic Letter to
the Editor about this paper
Right arrow Alert me when this article is cited
Right arrow Alert me when eLetters are posted
Right arrow Alert me if a correction is posted
Services
Right arrow Email this article to a friend
Right arrow Similar articles in this journal
Right arrow Similar articles in ISI Web of Science
Right arrow Similar articles in PubMed
Right arrow Alert me to new issues of the journal
Right arrow Download to citation manager
Right arrow reprints & permissions
Citing Articles
Right arrow Citing Articles via HighWire
Right arrow Citing Articles via ISI Web of Science (14)
Right arrow Citing Articles via Google Scholar
Google Scholar
Right arrow Articles by Plebani, M.
Right arrow Articles by Faggian, D.
Right arrow Search for Related Content
PubMed
Right arrow PubMed Citation
Right arrow Articles by Plebani, M.
Right arrow Articles by Faggian, D.
Related Collections
Right arrow Laboratory Management
Right arrow Clinical Immunology
(Clinical Chemistry. 1998;44:1974-1979.)
© 1998 American Association for Clinical Chemistry, Inc.


Clinical Immunology

Measurement of specific immunoglobulin E: intermethod comparison and standardization

Mario Plebania, Daniela Bernardi, Daniela Basso, Franco Borghesan, and Diego Faggian

Department of Laboratory Medicine, Azienda Ospedaliera di Padova, 35128 Padua, Italy.
a Address correspondence to this author at: Servizio di Medicina di Laboratorio, Azienda Ospedaliera di Padova, Via Giustiniani, 2, 35128 Padua, Italy. Fax 39-49-663240; e-mail mariopl{at}ux1.unipd.it.

Recently introduced "second-generation" techniques for specific IgE measurement have produced some analytical improvement, offering better clinical sensitivity than previous techniques. The aims of our study were to compare the analytical and clinical performances of four second-generation techniques for allergen-specific IgE measurement in serum and to ascertain whether the new system for reporting quantitative results contributes to greater clinical agreement between findings using the techniques considered. Allergen-specific IgE was measured using the CAP® System, CARLA®, ENEA®, and AlaSTAT®, and the findings were compared. A significant disagreement was found between CAP and ENEA for all allergens and between CAP and CARLA for D1 and G5. However, the clinical discrepancies were reduced by selecting method-specific thresholds using ROC analysis. Second-generation techniques enable us to obtain better standardization of results; however, the identification of a specific threshold appears to be a prerequisite for the appropriate clinical interpretation of the test findings.


Key Words: RAST, radio allergo sorbent test • kUa/L, kilounits of allergen-specific IgE per liter • AUC, area under the curve • CI, confidence interval.




The following articles in journals at HighWire Press have cited this article:


Home page
Clin. Chem.Home page
M. Ollert, S. Weissenbacher, J. Rakoski, and J. Ring
Allergen-Specific IgE Measured by a Continuous Random-Access Immunoanalyzer: Interassay Comparison and Agreement with Skin Testing
Clin. Chem., July 1, 2005; 51(7): 1241 - 1249.
[Abstract] [Full Text] [PDF]


Home page
Annals of Clinical & Laboratory ScienceHome page
T. M. Li, T. Chuang, S. Tse, D. Hovanec-Burns, and A. S. El Shami