Clinical Chemistry Siemens Point of Care - Urinalysis
HOME HELP FEEDBACK SUBSCRIPTIONS ARCHIVE SEARCH TABLE OF CONTENTS
 QUICK SEARCH:   [advanced]


     


Clinical Chemistry 45: 123-126, 1999;
This Article
Right arrow Full Text
Right arrow Full Text (PDF)
Right arrow Alert me when this article is cited
Right arrow Alert me if a correction is posted
Right arrow Citation Map
Services
Right arrow Email this article to a friend
Right arrow Similar articles in this journal
Right arrow Similar articles in Web of Science
Right arrow Similar articles in PubMed
Right arrow Alert me to new issues of the journal
Right arrow Download to citation manager
Right arrow reprints & permissions
Citing Articles
Right arrow Citing Articles via HighWire
Right arrow Citing Articles via Web of Science (15)
Right arrow Citing Articles via Google Scholar
Google Scholar
Right arrow Articles by Sinatra, M. A.
Right arrow Articles by Young, G. P.
Right arrow Search for Related Content
PubMed
Right arrow PubMed Citation
Right arrow Articles by Sinatra, M. A.
Right arrow Articles by Young, G. P.
Related Collections
Right arrow General Clinical Chemistry
(Clinical Chemistry. 1999;45:123-126.)
© 1999 American Association for Clinical Chemistry, Inc.


Articles

Interference of Plant Peroxidases with Guaiac-based Fecal Occult Blood Tests Is Avoidable

Marc A. Sinatra, D. James B. St. Johna and Graeme P. Young2

Department of Gastroenterology and University of Melbourne Department of Medicine, The Royal Melbourne Hospital, C/O Post Office, Victoria 3050, Australia.
a Author for correspondence. Fax 61 3 9342 7848; e-mail james.stjohn{at}nwhcn.org.au.

Peroxidase-rich fruits and vegetables are reputed to interfere with guaiac-based fecal occult blood tests. We added horseradish peroxidase to fecal samples and tested them with Hemoccult®, Hemoccult SENSA®, and hydrated Hemoccult. Positivity rates with Hemoccult and Hemoccult SENSA decreased rapidly as the time between smearing (preparation) and development increased, whereas they remained high with hydrated Hemoccult. For samples with added blood, positivity rates did not decrease with time. When 61 volunteers were tested on a standard restriction and on a challenge diet high in plant peroxidase, no positive results occurred during standard restriction. During the challenge diet, one volunteer was positive with Hemoccult and Hemoccult SENSA when development was delayed 24 h, and no volunteers were positive when it was delayed 48 h and 72 h. However, with hydrated Hemoccult, positives occurred in 13 of 61 volunteers at 24 h, 8 of 61 at 48 h, and 5 of 61 at 72 h. Thus, peroxidase-rich plant foods do not need to be excluded from the diet with Hemoccult and Hemoccult SENSA if development is delayed for at least 48 h after smearing. A delay of this duration will not solve the problem of plant peroxidase interference with hydrated Hemoccult.




The following articles in journals at HighWire Press have cited this article:


Home page
GutHome page
R J C Steele, P L McClements, G Libby, R Black, C Morton, J Birrell, N A G Mowat, J A Wilson, M Kenicer, F A Carey, et al.
Results from the first three rounds of the Scottish demonstration pilot of FOBT screening for colorectal cancer
Gut, April 1, 2009; 58(4): 530 - 535.
[Abstract] [Full Text] [PDF]


Home page
Ann Clin BiochemHome page
C. G Fraser
Faecal occult blood tests - eliminate, enhance or update?
Ann Clin Biochem, March 1, 2008; 45(2): 117 - 121.
[Abstract] [Full Text] [PDF]




HOME HELP FEEDBACK SUBSCRIPTIONS ARCHIVE SEARCH TABLE OF CONTENTS
Copyright © 1999 by the American Association for Clinical Chemistry.