Clinical Chemistry
HOME HELP FEEDBACK SUBSCRIPTIONS ARCHIVE SEARCH TABLE OF CONTENTS
 QUICK SEARCH:   [advanced]


     


Clinical Chemistry 45: 92-97, 1999;
This Article
Right arrow Full Text
Right arrow Full Text (PDF)
Right arrow Alert me when this article is cited
Right arrow Alert me if a correction is posted
Right arrow Citation Map
Services
Right arrow Email this article to a friend
Right arrow Similar articles in this journal
Right arrow Similar articles in Web of Science
Right arrow Similar articles in PubMed
Right arrow Alert me to new issues of the journal
Right arrow Download to citation manager
Right arrow reprints & permissions
Citing Articles
Right arrow Citing Articles via HighWire
Right arrow Citing Articles via Web of Science (11)
Right arrow Citing Articles via Google Scholar
Google Scholar
Right arrow Articles by Carrière, D.
Right arrow Articles by Pau, B.
Right arrow Search for Related Content
PubMed
Right arrow PubMed Citation
Right arrow Articles by Carrière, D.
Right arrow Articles by Pau, B.
Related Collections
Right arrow Clinical Immunology
Right arrow Hematology
Right arrow Automation and Analytical Techniques
(Clinical Chemistry. 1999;45:92-97.)
© 1999 American Association for Clinical Chemistry, Inc.


Articles

Whole Blood Capcellia CD4/CD8 Immunoassay for Enumeration of CD4+ and CD8+ Peripheral T Lymphocytes

Dominique Carrière1,a, Jean Pierre Vendrell2, Claude Fontaine1, Aline Jansen1, Jacques Reynes3, Isabelle Pagès2, Catherine Holzmann4, Michel Laprade1 and Bernard Pau5

1 Ligne de Recherche en Immunologie, Sanofi Recherche, 371 rue du professeur Joseph Blayac, 34184 Montpellier Cedex 04, France.

2 Laboratoire d'Immunologie des Infections Rétrovirales, Hôpital Lapeyronie, 34295 Montpellier, France.

3 Département des Maladies Infectieuses et Tropicales, Hôpital Gui de Chauliac, 34295 Montpellier, France.

4 Sanofi Diagnostics Pasteur, 92430 Marnes la Coquette, France.

5 Unité Mixte de Recherche 9921, Faculté de Pharmacie, 34060 Montpellier, France.
a Author for correspondence. Fax 33 4 67 10 60 00; e-mail dominique. carriere{at}sanofi.com.

We evaluated the Whole Blood Capcellia® CD4/CD8, an immunoenzymatic method that provides absolute counts of CD4+ and CD8+ T cells in peripheral blood. The assay is based on the separation of T cells by use of an anti-CD2 magnetic bead suspension, followed by reaction of the CD4 or CD8 molecules with the corresponding monoclonal antibody coupled to peroxidase. CD4-positive monocytes were excluded from the assay. Freeze-dried magnetic bead-T-cell complexes were used as calibrators. Capcellia counts from HIV-1-infected patients were compared with those obtained by flow cytometry as the comparison method. The results by Capcellia correlated well with those by flow cytometric analysis: r2 = 0.95; P <0.001; (y = 0.96x - 22.1); Sy|x = 64 for CD4; r2 = 0.81; P <0.001; (y = 1.26x - 76.4); Sy|x = 139 for CD8; n = 76. The correlation between CD4+ T-cell counts determined by two trained experimenters was significant (r2 = 0.96). Our results indicate that this new ELISA technique for lymphocyte immunophenotyping is an efficient alternative to flow cytometry.




The following articles in journals at HighWire Press have cited this article:


Home page
CVIHome page
P. Nouanthong, S. Pata, T. Sirisanthana, and W. Kasinrerk
A Simple Manual Rosetting Method for Absolute CD4+ Lymphocyte Counting in Resource-Limited Countries.
Clin. Vaccine Immunol., May 1, 2006; 13(5): 598 - 601.
[Abstract] [Full Text] [PDF]


Home page
CVIHome page
R. Kannangai, S. Ramalingam, M. V. Jesudason, T. S. Vijayakumar, O. C. Abraham, A. Zachariah, and G. Sridharan
Correlation of CD4+ T-Cell Counts Estimated by an Immunocapture Technique (Capcellia) with Viral Loads in Human Immunodeficiency Virus-Seropositive Individuals
Clin. Vaccine Immunol., November 1, 2001; 8(6): 1286 - 1288.
[Abstract] [Full Text] [PDF]




HOME HELP FEEDBACK SUBSCRIPTIONS ARCHIVE SEARCH TABLE OF CONTENTS
Copyright © 1999 by the American Association for Clinical Chemistry.